Panasonic NN-GT338MZTE / NN-GT338WZTE / NN-GT338MZPE / NN-GT338WZPE Simplified Service Manual ▷ View online

Unlike many other appliances, the microwave oven is high-
voltage, high-current equipment. Though it is free from danger
in ordinary use, extreme care should be taken during repair.
CAUTION
Servicemen should remove their watches & rings whenever working
close to or replacing the magnetron.
2.1. Check the grounding
Do not operate on a 2-wire extension cord. The microwave
oven is designed to be grounded when used. It is imperative,
therefore, to make sure it is grounded properly before
beginning repair work.
2.2. Warning about the electric
charge in the high voltage
capacitor
For about 30 seconds after the oven is turned off, an electric
charge remains in the high voltage capacitor.When replacing or
checking parts, remove the power plug from the outlet and
short the terminal of the high voltage capacitor (terminal of lead
wire from diode) to the chassis ground with an insulated handle
screwdriver to discharge. Please be sure to contact the chassis
ground side first then short to the output terminal.
WARNING
There is high-voltage present, with high-current capabilities in the
circuits of the high voltage winding and filament winding of the high
voltage transformer. It is extremely dangerous to work on or near
these circuits with oven energized.
DO NOT measure the voltage in the high voltage circuit including
filament voltage of magnetron.
WARNING
Never touch any circuit wiring with your hand nor with an insulated
tool during operation.
2.3. When troubleshooting any
parts or components is to be
replaced, always ensure that
the power cord is unplugged
from the wall outlet.
2.4. When the 8 Amp fuse is blown
due to the malfunction of
short switch:
WARNING
When the 8 Amp fuse is blown due to malfunction of the Short switch,
you must replace all of the components (Primary latch switch,
Secondary latch switch, Short switch and Power relay (RY1 & RY4)).
 1. This
is
mandatory.
Refer
to
“Measurement
and
Adjustments” for these switches.
 2. When replacing the fuse, confirm that it has the appropriate
rating.
 3. When replacing faulty switches, be sure mounting tabs are
not bent, broken or otherwise deficient in their ability to hold
the switches.
2 CAUTIONS TO BE OBSERVED WHEN
TROUBLESHOOTING
5
NN-GT338M / NN-GT338W
2.5. Avoid inserting nails, wire, etc.
through any holes in the unit
during operation.
Never insert a wire, nail or any other metal object through the
lamp holes on the cavity or any other holes or gaps, because
such objects may work as an antenna and cause microwave
leakage.
2.6. Verification after repair
 1. After repair or replacement of parts, make sure that the
screws of the oven, etc. are neither loose nor missing.
Microwave energy might leak if screws are not properly
tightened.
 2. Make sure that all electrical connections are tight before
inserting the plug into the wall outlet.
 3. Check for microwave energy leakage.
CAUTION OF
MICROWAVE RADIATION LEAKAGE
USE CAUTION NOT TO BECOME EXPOSED TO RADIATION
FROM THE MICROWAVE MAGNETRON OR OTHER PARTS
CONDUCTING MICROWAVE ENERGY.
IMPORTANT NOTICE
1.The following components have potentials above 2000V while the
appliance is operated.
* Magnetron
* High voltage transformer
* High voltage diode
* High voltage capacitor
Pay special attention to these areas.
2.When the appliance is operated with the door hinge or magnetron
adjusted incorrectly, the microwave leakage can exceed more than
5mW/cm
2
. After repair or exchange, it is very important to check that
magnetron and the door hinge is correctly installed.
6
NN-GT338M / NN-GT338W
WARNING
1. High voltage is present at the high voltage terminal of the high
voltage transformer during any cook cycle.
2. It is neither necessary nor advisable to attempt measurement of the
high voltage.
3. Before touching any oven components, or wiring, always unplug
the oven from its power source and discharge the high voltage
capacitor.
3.1. Primary, Secondary Latch
Switch Interlocks
 1. Unplug the lead connectors to Power Relay (RY1) and
verify continuity of the power relay (RY1) 1-2 terminals.
 2. Unplug lead connectors to primary Latch switch and Door
Switch.
 3. Test the continuity of switches at door opened and closed
positions with ohm meter (low scale).
Normal continuity readings should be as follows.
3.2. Short Switch
 1. Unplug lead wires from H.V.transformer primary terminals.
 2. Connect test probes of ohm meter to the disconnected
leads of the H.V. Transformer.
 3. Test the continuity of short switch with door opened and
closed positions using lowest scale of the ohm meter.
Normal continuity readings should be as follows.
3.3. High voltage transformer
 1. Remove connectors from the transformer terminals and
check continuity.
 2. Normal (cold) resistance readings should be as follows:
Secondary winding........................... Approx. 80
Ω~120 Ω
Filament winding.............................. Approx. 0
Primary winding................................. Approx. 0
Ω ~1 Ω
3.4. High voltage capacitor
 1. Check continuity of capacitor with meter on highest OHM
scale.
 2. A normal capacitor will show continuity for a short time, and
then indicate 9M
Ω once the capacitor is charged.
 3. A shorted capacitor will show continuous continuity.
 4. An open capacitor will show constant 9M
Ω.
 5. Resistance between each terminal and chassis should be
infinite.
3 COMPONENT TEST PROCEDURE
7
NN-GT338M / NN-GT338W
3.5. Magnetron
Continuity checks can only indicate an open filament or a
shorted magnetron. To diagnose for an open filament or
shorted magnetron:
 1. Isolate magnetron from the circuit by disconnecting the
leads.
 2. A continuity check across magnetron filament terminals
should indicate one ohm or less.
 3. A continuity check between each filament terminal and
magnetron case should read open.
3.6. Diode (U)
 1. Isolate the diode (U) from the circuit by disconnecting the
leads.
 2. With the ohmmeter set on the highest resistance scale,
measure the resistance across the diode terminals.Reverse
the meter leads and again observe the resistance
reading.Meter with 6V, 9V or higher voltage batteries should
be used to check the front-to-back resistance of the diode,
otherwise an infinite resistance may be read in both
directions.
A normal diode’s resistance will be infinite in one direction
and several hundred K
Ω in the other direction.
 3. With the ohmmeter set on the highest resistance scale,
measure the resistance across the protector diode
terminals. Reverse the meter leads and again observe the
resistance reading.
A normal protector diode’s resistance will be infinite in both
directions. It is faulty if it shows continuity in one or both
directions.
8