DOWNLOAD Panasonic NN-GD368M / NN-GT348W / NN-GD368MZPE / NN-GD368MZTE / NN-GT348WZPE / NN-GT348MZPE Service Manual ↓ Size: 2.97 MB | Pages: 29 in PDF or view online for FREE

Model
NN-GD368M NN-GT348W NN-GD368MZPE NN-GD368MZTE NN-GT348WZPE NN-GT348MZPE
Pages
29
Size
2.97 MB
Type
PDF
Document
Simplified Service Manual
Brand
Device
Home Appliance / MICROWAVE OVEN
File
nn-gd368m-nn-gt348w-nn-gd368mzpe-nn-gd368mzte-nn-g.pdf
Date

Panasonic NN-GD368M / NN-GT348W / NN-GD368MZPE / NN-GD368MZTE / NN-GT348WZPE / NN-GT348MZPE Simplified Service Manual ▷ View online

3.5. Inverter power supply (U)
DO NOT try to REPAIR H.V. Inverter power supply (U).
Replace complete H.V. Inverter(U) Unit.
WARNING: HIGH VOLTAGE
Test if failure codes H95, H97 or H98 appear when performing
the following procedure. It is recommended to use an AC line
input current ammeter for testing.
Test 1
 1. With the oven unit’s AC power supply cord is unplugged
from the wall outlet, unplug the 2 pin H.V. connector CN703
from the magnetron tube.
 2. Place 1 liter of water load into oven cavity.
 3. Plug in the oven’s AC power supply cord into outlet.
 4. Program DPC.
 a. Press Timer/Clock pad twice.
 b. Press Start pad once.
 c. Press Micro Power pad once.
 5. Program oven at High power for 1 minute and press [Start]
button.
 a. After approximately 23 seconds, oven stops operating.
 b. During
oven
operation,
the
input
current
is
approximately 0.5 to 1A. If both a and b are OK,
proceed to test 2.
INPUT CURRENT
FAILURE CODE
Unplug CN703
0.5 to 1A
Oven stops in 23
seconds after started.
Test 2
Continued from Test 1
 1. Unplug the oven’s AC power supply cord from outlet.
 2. Unplug 3 pin connector CN701. CN703 remains unplugged.
 3. Plug in the oven’s AC power supply cord into outlet.
 4. Program DPC.
 a. Press Timer/Clock pad twice.
 b. Press Start pad once.
 c. Press Micro Power pad once.
 5. Program oven at High power for 1 minute and press [Start]
button.
 a. After approximately 3 seconds, oven stops operating.
 b. During
oven
operation,
the
input
current
is
approximately 0.4A.
INPUT CURRENT
FAILURE CODE
Unplug CN701
0.4A
Oven stops in 3
seconds after started.
If both a and b check OK, the Inverter Power Supply (U) can be
determined to be OK.
3.6. Temperature thermistor
These sensor monitors the heat produced by the heater circuit
and maintains the magnetron temperature which user had
selected. Normal room temperature 10°C to 30°C, the reading
across the temperature thermistor should be as follows.
TEMP
MAGNETRON THERMISTOR
100°C
30-60K
25°C
700K-1.5M
If the resistance reading is out of the range stated here, the
thermistor is detective and must be replaced.
9
NN-GD368M / NN-GT348W
4.1. Adjustment of Primary latch
switch, Secondary latch
switch and Short switch.
 1. Mount the Primary latch swith, the Secondary latch switch
and the Short switch to the door hook assembly as shown
in illustration.
NOTE:
No
specific
individual
adjustments
during
installation of the Primary latch switch, Secondary
latch switch or Short switch to the door hook are
required.
 2. When mounting the door hook assembly to the oven
assembly, adjust the door hook assembly by moving it in
the direction of the arrows in the illustration so that the oven
door will not have any play in it. Check for play in the door
by pulling the door assembly. Make sure that the latch keys
move smoothly after adjustment is completed. Completely
tighten the screws holding the door hook assembly to the
oven assembly.
 3. Reconnect the short switch and check the coninuity of the
monitor circuit and all latch switches again by following the
component test procedures.
4.2. Measurement of microwave
output
The output power of the magnetron can be determined by
performing IEC standard test procedures. However, due to the
complexity of IEC test procedures, it is recommended to test
the magnetron using the simple method outlined below.
Necessary Equipment:
  • 1 liter beaker
  • Glass thermometer
  • Wrist watch or stopwatch
NOTE:
Check the line voltage under load.Low voltage will
lower the magnetron output. Take the temperature
readings and heating time as accurately as possible.
 1. Fill the beaker with exactly one liter of tap water. Stir the
water using the thermometer and record the water’s
temperature. (recorded as T1).
 2. Place the beaker on the center of glass tray.
Set the oven for High power and heat it for exactly one
minute.
 3. Stir the water again and read the temperature of the water.
(recorded as T2).
 4. The normal temperature rise at High power level for each
model is as shown in table.
TABLE (1L-1min.test)
RATED OUTPUT
TEMPERATURE RISE
850W
Min.13.1°F(7.5°C)
4 MEASUREMENTS AND ADJUSTMENTS
10
NN-GD368M / NN-GT348W
5 TROUBLESHOOTING GUIDE
DANGER: HIGH VOLTAGES
1. DO NOT RE-ADJUST PRESET CONTROL on the H.V.Inverter (U). It is very dangerous to repair or adjust without proper test equipment
because this circuit generates very large current and high voltage. Operating a misaligned inverter circuit is dangerous.
2. Ensure proper grounding before troubleshooting.
3. Be careful of the high voltage circuitry, taking necessary precautions when troubleshooting.
4. Discharge high voltage remaining in the H.V.Inverter (U).
5. When checking the continuity of the switches or the H.V.Inverter, disconnect one lead wire from these parts and then check continuity with the
AC plug removed. Doing otherwise may result in a false reading or damage to your meter. When disconnecting a plastic connector from a
terminal, you must hold the plastic connector instead of the lead wire and then disconnect it, otherwise lead wire may be damaged or the
connector cannot be removed.
6. Do not touch any parts of the circuitry on the digital programmer circuit, since static electric discharge may damage this control panel. Always
touch ground while working on this panel to discharge any static charge in your body.
7. 220V AC is present on the digital programmer circuit (Terminals of power relay’s and primary circuit of Digital Programmer Circuit). When
troubleshooting, be cautious of possible electrical shock hazard.
Before troubleshooting, operate the microwave oven following the correct operating procedures in the instruction manual in order
to find the exact cause of any trouble, since operator error may be mistaken for the oven’s malfunction.
5.1. (Troubleshooting) Oven stops operation during cooking
SYMPTOM
CAUSE
CORRECTIONS
1. Oven stops in 3 seconds after
pressing [Start] pad.
No input AC is supplied to H.V.Inverter (U)
CN702 terminals
1. Latch Switch
2. Power relay RY1
3. Loose lead wire connector CN701, CN702
4. H.V. Inverter (U)
Oven stops in 23 seconds after
pressing [Start] pad.
H.V.Inverter (U) operates by the control signals
from DPC but magnetron is not oscillating
1. Magnetron
2. Loose lead wire connector CN703
3. H.V. Inverter (U)
2. No display and no operation at all.
Fuse is blown.
Most probably loose connection of connectors, or
door latch mechanism is not adjusted properly
1. Align door, Door Latch Switches
2. Loose wiring connectors
11
NN-GD368M / NN-GT348W
5.2. (Troubleshooting) Other problems
SYMPTOM
CAUSE
CORRECTIONS
1. Oven is dead.
1. Open or loose lead wire harness
Check thermal cutout is defective.
Fuse is OK.
2. Open thermal cutout / thermistor
No display and no operation at all.
3. Open low voltage transformer
4. Defective DPC
2. No display and no operation at all.
Fuse is blown.
1.
2.
Shorted lead wire harness
Defective primary latch switch (NOTE 1)
Check adjustment of primary, secondary latch
switch and short switch including door.
3. Defective short switch (NOTE 1)
4. Defective Inverter Power Supply (U)
NOTE 1:
All of these switches must be replaced at the same time.
Check continuity of power relay RY1 contacts (between 1 and 2) and if it has continuity, replace
power relay RY1 also.
3. Oven does not accept key input
(Program)
1.
2.
Key input is not in proper sequence
Open or loose connection of membrane key
pad to DPC (Flat cable)
Refer to operation procedure.
3. Shorted or open membrane key board
4. Defective DPC
Refer to DPC troubleshooting.
4. Fan motor turns on when oven is
plugged in with door closed.
1. Misadjustment or loose wiring of secondary
latch switch
Adjust door and latch switches.
2. Defective secondary latch switch
3. Door switch CN3
5. Timer starts count down but no
microwave oscillation.
(No heat while oven lamp and fan
motor turn on)
1.
2.
Off-alignment of primary latch switch
Open or loose connection of high voltage circuit
especially magnetron filament circuit
NOTE:
Large contact resistance will cause lower
magnetron
filament
voltage
and
cause
magnetron to have lower output and/or be
intermittent.
Adjust door and latch switches.
3. Defective high voltage component
H.V. Inverter Power Supply (U)
Magnetron
Check high voltage component according to
component test procedure and replace if it is
defective.
4. Open or loose wiring of power relay RY1
5. Defective primary latch switch
6. Defective DPC or power relay RY1
Refer to DPC troubleshooting
6. Oven can program but timer does not
start countdown.
1. Open or loose wiring of secondary latch switch
2. Off-alignment of secondary latch switch
3. Defective secondary latch switch
7. Microwave output is low. Oven takes
longer time to cook food.
1. Decrease in power source voltage
Consult electrician
2. Open or loose wiring of magnetron filament
circuit.(Intermittent oscillation)
3. Aging change of magnetron
8. Fan motor turns on and turntable
motor rotates when door is opened.
1. Low voltage transformer on DPC.
9. Oven does not operate and return to
plugged in mode as soon as [Start]
button is pressed.
1. Defective DPC
Check grounding connector on escutcheon
base.
10. Loud buzzing noise can be heard.
1. Loose fan and fan motor
11. Heater does not turn on.
1. Open or loose wiring of heater
2. Defective heater
3. Defective power relay
4. Defective DPC
12. Oven stops operation during cooking.
1. Open or loose wiring of primary and
secondary latch switch
Adjust door and latch switches.
2. Operation of thermal cutout
12
NN-GD368M / NN-GT348W
Page of 29
Display

Click on the first or last page to see other NN-GD368M / NN-GT348W / NN-GD368MZPE / NN-GD368MZTE / NN-GT348WZPE / NN-GT348MZPE service manuals if exist.