DOWNLOAD Panasonic EH5571 / EH5572 / EH5573 / EH5571K865 / EH5573S865 Service Manual ↓ Size: 496.77 KB | Pages: 20 in PDF or view online for FREE

Model
EH5571 EH5572 EH5573 EH5571K865 EH5573S865
Pages
20
Size
496.77 KB
Type
PDF
Document
Service Manual
Brand
Device
Home Appliance / HAIR DRYER
File
eh5571-eh5572-eh5573-eh5571k865-eh5573s865.pdf
Date

Panasonic EH5571 / EH5572 / EH5573 / EH5571K865 / EH5573S865 Service Manual ▷ View online

(15) Assembly Housing C ,Air Inlet Ring and Air Outlet Ring 
     and drive screws as shown in Figure 19 ,finally assembly
     Air Inlet Frame and Nozzle as shown in Figure 20
Figure 19
13
4  DISASSEMBLY  INSTRUCTIONS
(1)  Remove the 2 torx screws from main body with
      a torx head driver as shown in Figure 21
 
(2)  Take Air Inlet Frame off and then remove 
      4 screws from Main body from front
      and back and remove Air Outlet Ring and
      Air Inlet Ring by rotate clockwise
      and then pull out.
(3)  Separate Housing C from Housing A/B by release left and right hook
      as indication "A" and apply separate force at indication "F" gently.
Figure 21
Figure 22
Figure 23
Figure 24
Figure 25
14
5   TROUBLESHOOTING  GUIDE
Refer to WIRING CONNECTION DIAGRAM.
 
To be continued
Hot air is not 
emitted at 
position 
Hot-3
Hot-2
Hot-1
Warm-3
Warm-2
Warm-1
Mild-3
Mild-2
Mild-1
or cool air is  
not emitted 
at position
Cool-3
Cool-2
Cool-1
< TROUBLE >
< CHECK >
< REMEDY >
 Check continuity of power cord.
 Replace power  
cord.
Check continuity between "6-9"
, "7-9"and "8-10"  of Temp switch at 
position "Hot" 
Check continuity between "6-9"
"7-9" of Temp switch ("8-10" open)
at position "Warm"
Check continuity between "6-9"
 of Temp switch("7-9","8-10" open)
at position "Mild"
Check continuity between 
"6-9","7-9","8-10"  must be opened
at position "Cool"
OK
 Replace 
Temp  switch.
NG
Check continuity between "1-4"
, "2-4"and "3-5"  of Main Switch at position "3"
Check continuity between "1-4"
"2-4" of Main Switch ("3-5" open)
at position "2"
Check continuity between "1-4"
 of Main Switch("2-4","3-5" open)
at position "1"
OK
NG
Replace Main 
switch.
NG
OK
15
5   TROUBLESHOOTING  GUIDE
Refer to WIRING CONNECTION DIAGRAM.
 
To be continue
Hot air is not 
emitted at 
position 
Hot-3
Hot-2
Hot-1
Warm-3
Warm-2
Warm-1
Mild-3
Mild-2
Mild-1
or cool air is  
not emitted 
at position
Cool-3
Cool-2
Cool-1
< TROUBLE >
< CHECK >
< REMEDY >
Replace Heater
Block.
NG
Set Temp Switch and Main Switch to Hot-3
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 37.2
Ω
EH5571    : appox. 40.2
Ω
Set Temp Switch and Main Switch to Hot-2
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 42.7
Ω
EH5571    : appox. 45.3
Ω
Set Temp Switch and Main Switch to Hot-1
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 69.5
Ω
EH5571    : appox. 72.6
Ω
Set Temp Switch and Main Switch to Warm-3
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 50.8
Ω
EH5571    : appox. 56.0
Ω
Set Temp Switch and Main Switch to Warm-2
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 56.4
Ω
EH5571    : appox. 61.4
Ω
Set Temp Switch and Main Switch to Warm-1
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 83.1
Ω
EH5571    : appox. 88.5
Ω
16
Page of 20
Display

Click on the first or last page to see other EH5571 / EH5572 / EH5573 / EH5571K865 / EH5573S865 service manuals if exist.