Panasonic EH-NE84-K865 Service Manual ▷ View online
1. Warning
Caution:
- Pb free solder has a higher melting point that standard solder; Typical the melting point is 50 - 70°F (30 - 40
℃) higher.
Please use soldering iron with temperature control and adjust it to 750 ±20°F (400 ± 10
℃).
In case of using high temperature soldering iron, please becareful not to heat too long.
- Pb free solder will tend to splash when heated too high (about 1100°F / 600
℃).
Power source
Power consumption
(" II - Hot ")
Air volume without nozzle
Air temperature without nozzle
(" II - Hot ")
Dimensions
Cord length
Weight
Supplied accessory
90 K (in case of room temperature 30°C)
(W) 90mm x (D) 220mm. x (H) 270mm.
(without power cord and nozzle)
2. Specifications
AC 220-240 V , 50~60 Hz
Code 865 = 1.7 m
Approx. =560g.
Set nozzle and diffuser nozzle
AC 220 V, 50~60 Hz, 2100 W
AC 230 V, 50~60 Hz, 2300 W
AC 240 V, 50~60 Hz, 2500 W
1.9 m
3
/min
3. TROUBLESHOOTING GUIDE
Refer to WIRING CONNECTION DIAGRAM.
Replace MOTOR HEATER ASSEMBLY
< TROUBLE >
< CHECK >
< REMEDY >
Main body is
not operated
not operated
<CHECK POWER CORD>
Check the conductivity of power cord
<CHECK MAIN SWITCH>
Check the conductivity between the terminal 1
and 4 by setting
the MAIN SWITCH to Position 1
(Figure 1)
Replace the
MAIN SWITCH
Replace the
MOTOR HEATER
ASSEMBLY
NG
OK
NG
OK
Replace the
MOTOR HEATER
ASSEMBLY
Lead Wire (Yellow)
Lead Wire (Red)
Lead Wire (Gray)
Lead Wire (Orange)
*For code : 605, 655, 685, 695, 865
MAIN SWITCH
Figure 1
Control point
Thermistor must
be placed at
the center of hole
Thermistor
<CHECK TEMPERATURE SWITCH>
Check the conductivity between the terminal 1
and 4 by setting
the TEMPERATURE SWITCH to Position 1
(Figure 4)
Replace the
TEMPERATURE SWITCH
NG
Figure 4
Replace PRINTED CIRCUIT ASSEMBLY
OK
Figure 2
For EH-NE82 and 84 only
Advance heat protection mode is not
operated or not operated follow spec
operated or not operated follow spec
(Figure 2)
*Air keep switching between hot and cold
while this mode is operating
<CHECK THERMISTOR>
Check the position of thermistor
(Figure 3)
Adjust the position
of thermistor follow
control point
NG
OK
Figure 3
Environmental
Interval time (sec)
29.1
º
C or more 2.0 ~ 4.5
5.0 ~ 8.0
temperature
Hot air
Cold air
23.9
º
C or less
3.0 ~ 8.0
2.0 ~ 4.5
24 ~ 29
º
C
2.0 ~ 6.0
2.0 ~ 5.5
*Check interval time after operate on this mode for 30 sec
OK
Lead Wire (Black)
Lead Wire (Brown)
Lead Wire (Orange)
Temperature switch
3. TROUBLESHOOTING GUIDE
Refer to WIRING CONNECTION DIAGRAM.
< TROUBLE >
< CHECK >
< REMEDY >
OK
<CHECK MOTOR HEATER ASSEMBLY>
Check if there are odd objects between
joints of thermo switch or not
(Figure 7)
Remove the odd objects
between joints
Found odd object
No odd objects
Replace the
MOTOR HEATER ASSEMBLY
Figure 7
Thermo Switch
Hot air is not emitted
<CHECK COOL SWITCH BUTTON>
Check the conductivity between the terminal 1
and 2 by push and hold
the COOL SWITCH BUTTON
(Figure 6)
<CHECK TEMPERATURE SWITCH>
Check the conductivity between the terminal 2
and 4 by setting
the TEMPERATURE SWITCH to Position 2
(Figure 5)
Replace the
MAIN SWITCH
NG
OK
Replace the
COOL SWITCH BUTTON
NG
COOL SWITCH BUTTON
Lead Wire (Orange)
Lead Wire (Blue and Red)
For EH-NE81-84
Figure 6
Figure 5
Lead Wire (Black)
Lead Wire (Brown)
Lead Wire (Orange)
Temperature Switch
OK
4. Disassembly and Assembly Instructions
4.1. Disassembly Instructions
1. Remove the FILTER FRAME ASSEMBLY
4. Remove TAPPING SCREWS by a cross
slot screw driver. Than take out AIR OUTLET RING
and AIR OUTLET GRILL by rotating follow the direction
below.
slot screw driver. Than take out AIR OUTLET RING
and AIR OUTLET GRILL by rotating follow the direction
below.
2. Remove three TAPPING SCREWS by a cross
slot screw driver,then Remove AIR INLET RING.
slot screw driver,then Remove AIR INLET RING.
5. Take off HOUSING AB follow the figure below.
3. Remove 2 TAPPING SCREWS at HOUSING A
by flat-blade screwdriver and 2 TORX SCREWS
at HANDLE by Driver then remove HANDLE AB.
by flat-blade screwdriver and 2 TORX SCREWS
at HANDLE by Driver then remove HANDLE AB.
6. Remove DISCHARGE COVER
Counter clockwise rotation