Panasonic UF-6300 / UF-6200 / UF-5300 Service Manual ▷ View online
93
4.3.11. Information Code: 630 (Dialing Error)
START
END
END
Yes
No
Is there a dial tone when
MONITOR button is
pressed?
MONITOR button is
pressed?
1. Connect the telephone
line correctly.
2. Check the telephone line.
line correctly.
2. Check the telephone line.
Yes
No
Is the remote machine busy?
Can the unit dial the
reference unit?
reference unit?
No
1. Check all connectors.
2. Replace the SC PCB.
2. Replace the SC PCB.
1. The remote machine is
defective.
2. Telephone line quality is
poor.
(Refer to Sect. 4.6.)
defective.
2. Telephone line quality is
poor.
(Refer to Sect. 4.6.)
Press the REDIAL button to
retry connection.
retry connection.
Yes
94
4.3.12. Information Codes: 403, 411, 414, 415 (Polling Operator Trouble)
403, 411, 414
START
END
END
Review the polling operation
referring to the Operating
Instructions.
referring to the Operating
Instructions.
Yes
Yes
No
Does the remote side have
polling transmission
capability?
polling transmission
capability?
No
Ask the remote side to set
their unit for polling operation.
their unit for polling operation.
Is the remote side set to
polling transmission
(Polled) Mode?
polling transmission
(Polled) Mode?
Check the password
between the two units to
ensure it matches.
between the two units to
ensure it matches.
415
START
END
Inform the remote side
(receiving side) that their
machine does not have
polling transmission
capability.
(receiving side) that their
machine does not have
polling transmission
capability.
Polling communication with 4-digit password is not an ITU-T Standard feature.
If the transmitter and receiver are of different manufacturers, polling communication
with password
If the transmitter and receiver are of different manufacturers, polling communication
with password
may not be possible.
95
4.4.
Printed Copy Quality Problems
4.4.1.
Black Copy
START
No
Yes
Check the Scanner mechanism.
Is the Power Supply
Unit normal?
Unit normal?
Is the SC PCB normal?
Is the Toner Cartridge
operational?
operational?
Replace the Toner Cartridge.
1. Check all connectors and voltages
on the Power Supply Unit.
2. Check the contacts between
PSU and Toner Cartridge.
on the Power Supply Unit.
2. Check the contacts between
PSU and Toner Cartridge.
3. Replace the PSU.
Yes
No
Yes
Yes
No
No
1. Check all connectors and voltages
on the SC PCB.
2. Replace the SC PCB.
on the SC PCB.
2. Replace the SC PCB.
END
Paper Travel
Is the printout in Service
Mode 3 normal?
Mode 3 normal?
96
4.4.2.
Blank Copy
START
END
Check the Scanner mechanism.
Are there any foreign particles
or stains on the BTR?
or stains on the BTR?
Is the Toner Cartridge
operational?
operational?
Is the Power Supply Unit
normal?
normal?
Yes
Yes
Yes
No
No
No
Replace the Toner Cartridge .
Yes
No
1. Clean the BTR with a soft,
dry cloth.
dry cloth.
2. Replace the BTR.
1. Check all connectors and
voltages on the Power Supply
Unit.
2. Check the Connector and
voltage on the Power
Supply Unit.
3. Replace the Power Supply Unit.
voltages on the Power Supply
Unit.
2. Check the Connector and
voltage on the Power
Supply Unit.
3. Replace the Power Supply Unit.
Are there any foreign particles
or stains blocking the Laser
Beam path?
or stains blocking the Laser
Beam path?
Yes
No
Is the SC PCB normal?
1. Remove the particles from the
laser beam path or clean the stains.
2. Replace the Laser Unit (LSU).
laser beam path or clean the stains.
2. Replace the Laser Unit (LSU).
1. Check all connectors and
voltages on the SC PCB.
2. Replace the SC PCB.
Yes
No
Paper Travel
Is the printout in Service
Mode 3 normal?
Mode 3 normal?
Click on the first or last page to see other UF-6300 / UF-6200 / UF-5300 service manuals if exist.