Panasonic UE-407019NA Service Manual / Supplement ▷ View online
Chapter 4
Troubleshooting
This chapter covers only the differences from the UF-885/895 Service Manual.
Panasonic G3 Communication Port Kit
26
4 Troubleshooting
4.1
Information Code Table
Information Codes
Code
Mode
Phase
Description of Problem
Cause
340 -
-
Interface failure between the G3B PC Board and
the FCB PC Board.
the FCB PC Board.
FRM PC Board incorrectly installed on the G3B
PC Board.
Defective FRM PC Board.
Defective G3B PC Board.
Defective FCB PC Board.
PC Board.
Defective FRM PC Board.
Defective G3B PC Board.
Defective FCB PC Board.
Chapter 5
Service Modes
This chapter covers only the differences from the UF-885/895 Service Manual.
Panasonic G3 Communication Port Kit
28
5 Service Modes
5.1
Service Mode 1 (Function Parameter Setting)
Use the following procedure to change the function parameters.
Note 1:
The following buttons provide these functions in the test mode:
"START" : The new setting value is stored in the machine.
"\/" : Scrolls the function parameter number down.
"/\" : Scrolls the function parameter number up.
"START" : The new setting value is stored in the machine.
"\/" : Scrolls the function parameter number down.
"/\" : Scrolls the function parameter number up.
Step
Operation or Unit Condition
LCD Display
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Press “1”.
5
Enter the Function Parameter Number.
Ex: Changing the "DC LOOP" -- Enter "209" and press [SET].
Ex: Changing the "DC LOOP" -- Enter "209" and press [SET].
6
Press “START”.
7
Enter the new setting value.
Ex: Enter "2" for On.
Ex: Enter "2" for On.
8
Press “START”. The new value will be stored and the next parameter will be
displayed.
displayed.
9
Repeat steps 4 through 7 to change other Function Parameters or Press
“STOP” twice to return to standby.
“STOP” twice to return to standby.
MAY-12-1999 15:00
00%
SET MODE (1-6)
ENTER NO. OR
SERVICE MODE
ENTER NO. OR
PARAMETER (000-299)
ENTER PARAMETER #_
PARAMETER #209
DC LOOP?
DC LOOP:Off
1:OFF 2:ON
DC LOOP:On
1:OFF 2:ON
PARAMETER #210
TX LEVEL?
MAY-12-1999 15:00
00%