DOWNLOAD Panasonic KX-FT982RU / KX-FT984RU / KX-FT988RU Service Manual ↓ Size: 5.59 MB | Pages: 127 in PDF or view online for FREE

Model
KX-FT982RU KX-FT984RU KX-FT988RU
Pages
127
Size
5.59 MB
Type
PDF
Document
Service Manual
Brand
Device
Fax / PERSONAL FACSIMILE / FACSIMILE WITH DIGITAL ANSWERING SYSTEM
File
kx-ft982ru-kx-ft984ru-kx-ft988ru.pdf
Date

Panasonic KX-FT982RU / KX-FT984RU / KX-FT988RU Service Manual ▷ View online

33
KX-FT982RU-B / KX-FT982RU-W / KX-FT984RU-B / KX-FT988RU-B / KX-FT988RU-W
6. Explanation of Communication and Compression Technology
a. G3 Communication Signals (T. 30 Binary Process) 
For G3 Facsimile communication, this is the procedure for exchanging control signals between the sending and receiving
machines both before and after transmission of image signals.
Control signals at 300 bps FSK are: 1850 Hz...0, 1650Hz...1. 
An example of a binary process in G3 communication is shown below.
Explanation of Signals 
Control signals are comprised mainly of 8-bit identification signals and the data signals added to them. Data signals are added
to DIS and DCS signals.
Signal.....DIS (Digital Identification Signal) 
Identification Signal Format.....00000001
Function:
Notifies the capacity of the receiving unit. The added data signals are as follows.
Signal.....DCS (Digital Command Signal) 
Identification Signal Format.....X1000001
Example (Some models do not support the following items.):
Bit No.
DIS/DTC
DCS
1
Transmitter --- T.2 operation
2
Receiver --- T.2 operation
Receiver --- T.2 operation
3
T.2 IOC = 176
T.2 IOC = 176
4
Transmitter --- T.3 operation
5
Receiver --- T.3 operation
Receiver --- T.3 operation
6
Reserved for future T.3 operation features
7
Reserved for future T.3 operation features.
8
Reserved for future T.3 operation features.
9
Transmitter --- T.4 operation
34
KX-FT982RU-B / KX-FT982RU-W / KX-FT984RU-B / KX-FT988RU-B / KX-FT988RU-W
10
Receiver --- T.4 operation
Receiver --- T.4 operation
11,12,13,14
0,0,0,0
0,1,0,0
1,0,0,0
1,1,0,0
0,0,1,0
0,1,1,0
1,0,1,0
1,1,1,0
0,0,0,1
0,1,0,1
1,0,0,1
1,1,0,1
0,0,1,1
0,1,1,1
1,0,1,1
1,1,1,1
Data signaling rate
V.27 ter fall back mode
V.27 ter 
V.29
V.27 ter and V.29
Not used
Reserved
Not used
V.27 ter and V.29 and V.33
Not used
Reserved
Not used
V.27 ter and V.29 and V.33 and V.17
Not used
Reserved
Not used
Reserved
Data signaling rate
2400 bit/s, V.27 ter
4800 bit/s, V.27 ter
9600 bit/s, V.29
7200 bit/s, V.29
14400 bit/s, V.33
12000 bit/s, V.33
Reserved
Reserved
14400 bit/s, V.17
12000 bit/s, V.17
9600 bit/s, V.17
7200 bit/s, V.17
Reserved
Reserved
Reserved
Reserved
15
R8
×7.7 lines/mm and/or 200×200 pels/25.4mm
R8
×7.7 lines/mm and/or 200×200 pels/25.4mm
16
Two-dimensional coding capability
Two-dimensional coding capability
17, 18
(0, 0)
(0, 1)
(1, 0)
(1, 1)
Recording width capabilities
1728 picture elements along scan line length of 
    215 mm ± 1%
1728 picture elements along scan line length of 
    215 mm ± 1%
2048 picture elements along scan line length of 
    255 mm ± 1%
2432 picture elements along scan line length of 
    303 mm ± 1%
1728 picture elements along scan line length of 
    215 mm ± 1%
2048 picture elements along scan line length of 
    255 mm ± 1%
Invalid
Recording width
1728 picture elements along scan line length of 
    215 mm ± 1%
2432 picture elements along scan line length of 
    303 mm ± 1%
2048 picture elements along scan line length of 
    255 mm ± 1%
Invalid
19, 20
(0, 0)
(0, 1)
(1, 0)
(1, 1)
Maximum recording length capability
A4 (297 mm)
Unlimited
A4 (297 mm) and B4 (364 mm)
Invalid
Maximum recording length
A4 (297 mm)
Unlimited
B4 (364 mm)
Invalid
21, 22, 23
(0, 0, 0)
(0, 0, 1)
(0, 1, 0)
(1, 0, 0)
(0, 1, 1)
(1, 1, 0)
(1, 0, 1)
(1, 1, 1)
Minimum scan line time capability of the receiver
20 ms at 3.85 l/mm: T
7.7
 = T
3.85
40 ms at 3.85 l/mm: T
7.7
 = T
3.85
10 ms at 3.85 l/mm: T
7.7
 = T
3.85
  5 ms at 3.85 l/mm: T
7.7
 = T
3.85
10 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
20 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
40 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
  0 ms at 3.85 l/mm: T
7.7
 = T
3.85
Minimum scan line time
20 ms
40 ms
10 ms
  5 ms
  0 ms
24
Extend field
Extend field
25
2400 bit/s handshaking
2400 bit/s handshaking
26
Uncompressed mode
Uncompressed mode
27
Error correction mode
Error correction mode
28
Set to "0".
Frame size 0 = 256 octets     1 = 64 octets
29
Error limiting mode
Error limiting mode
30
Reserved for G4 capability on PSTN
Reserved for G4 capability on PSTN
31
T.6 coding capability
T.6 coding enabled
32
Extend field
Extend field
33
(0)
(1)
Validity of bits 17, 18
Bits 17, 18 are valid
Bits 17, 18 are invalid
Recording width
Recording width indicated by bits 17, 18
Recording width indicated by this field bit information
34
Recording width capability 1216 picture elements along
scan line length of 151 ± mm 1%
Middle 1216 elements of 1728 picture elements
35
Recording width capability 864 picture elements along scan
line length of 107 ± mm 1%
Middle 864 elements of 1728 picture elements
36
Recording width capability 1728 picture elements along
scan line length of 151 ± mm 1%
Invalid
37
Recording width capability 1728 picture elements along
scan line length of 107 ± mm 1%
Invalid
38
Reserved for future recording width capability.
Bit No.
DIS/DTC
DCS
35
KX-FT982RU-B / KX-FT982RU-W / KX-FT984RU-B / KX-FT988RU-B / KX-FT988RU-W
Note 1 - Standard facsimile units conforming to T.2 must have the following capability: Index of cooperation (IOC)=264.
Note 2 - Standard facsimile units conforming to T.3 must have the following capability: Index of cooperation (IOC)=264.
Note 3 - Standard facsimile units conforming to T.4 must have the following capability: Paper length=297 mm.
39
Reserved for future recording width capability.
40
Extend field
Extend field
41
R8
×15.4 lines/mm
R8
×15.4 lines/mm
42
300
×300 pels/25.4 mm
300
×300 pels/25.4 mm
43
R16
×15.4 lines/mm and/or 400×400 pels/25.4 mm
R16
×15.4 lines/mm and/or 400×400 pels/25.4 mm
44
Inch based resolution preferred
Resolution type selection
"0": neritic based resolution
"1": inch based resolution
45
Metric based resolution preferred
Don’t care
46
Minimum scan line time capability for higher resolutions
"0": T
15.4
 = T
7.7
       "1": T
15.4
 = 1/2T
7.7
Don’t care
47
Selective Polling capability
Set to "0".
48
Extend field
Extend field
Signal
Identification Signal Format
Function
Training 1
———————
A fixed pattern is transmitted to the receiving side at a speed (2400
bps to 9600 bps) designated by DCS, and the receiving side opti-
mizes the automatic equalizer, etc., according to this signal.
TCF
(Training Check)
———————
Sends 0 continuously for 1.5 seconds at the same speed as the
training signal.
CFR 
(Confirmation to Receive)
X0100001
Notifies the sending side that TCF has been properly received. If
TCF is not properly received, FTT (Failure To Train) X0100010 is
relayed to the sender. The sender then reduces the transmission
speed by one stage and initiates training once again.
Training 2
———————
Used for reconfirming the receiving side like training 1.
Image Signal
Refer to the next page.
———————
RTC
(Return to Control)
———————
Sends 12 bits (0...01 
× 6 times) to the receiver at the same speed as
the image signal and notifies completion of transmission of the first
sheet.
EOP
(End of Procedure)
X1110100
End of one communication
MCF
(Message Confirmation)
X0110001
End of 1 page reception
DCN
(Disconnect)
X1011111
Phase E starts.
MPS
(Multi-Page Signal)
X1110010
Completion of transmission of 1 page. If there are still more docu-
ments to be sent, they are output instead of EOP. After MCF recep-
tion, the sender transmits an image signal of the second sheet.
PRI-EOP
(Procedural Interrupt-EOP)
X1111100
If there is an operator call from the sender, it is output after RTC.
PIP
(Procedural Interrupt Positive)
X0110101
This is output when an operator call is received.
Bit No.
DIS/DTC
DCS
36
KX-FT982RU-B / KX-FT982RU-W / KX-FT984RU-B / KX-FT988RU-B / KX-FT988RU-W
b. Redundancy Compression Process Coding Mode 
This unit uses one-dimensional MH format.
Page of 127
Display

Click on the first or last page to see other KX-FT982RU / KX-FT984RU / KX-FT988RU service manuals if exist.