 2. Program Mode Table
Code
Function
Set Value
Default
Remote setting
001
Set the date and time
dd/mm/yy hh:mm AM/PM
---------
NG
002
Your logo
---------
---------
NG
003
Your telephone number
---------
---------
NG
004
Print transmission report
1:ERROR 2:ON 3:OFF
ERROR
OK
005
Auto receive mode
1:TEL/FAX 2: FAX ONLY 3: TAD/FAX TAD/FAX
OK
006
TAD/FAX ring count
1~4:TOLL SAVER/RINGER OFF
1
OK
007
FAX ring count
1 to 4 rings
1 ring
OK
009
TEL/FAX delayed ring
1 to 4 rings
1 ring
OK
010
Recording time
1:VOX/2:1 MIN
VOX
OK
011
Remote ANS ID
---------
ID=111
NG
013
Dialing mode
1:PULSE 2:TONE
TONE
OK
022
Journal auto print
1:ON 2:OFF
ON
OK
023
Overseas mode
1:ON 2:OFF
OFF
OK
025
Delayed send
ON/OFF
OFF
NG
030
Silent FAX recognition ring
3 to 9 rings
3 rings
OK
031
Ring detection
0:OFF 1:A 2:B 3:C 4:D
OFF
OK
041
FAX activation code
ON/OFF
ON/ID=*9
NG
042
Message alert
1:ON 2:OFF
OFF
OK
043
REC. time alert
1:ON 2:OFF
OFF
OK
046
Friendly reception
1:ON 2:OFF
ON
OK
048
Lauguage swith
1:ENGLISH 2:SPANISH
SPANISH
OK
049
Auto disconnect
ON/OFF
ON
NG
054
Common greeting MSG. REC. time
1:16s 2:60s
16s
OK
058
Original setting
1:NORMAL 2:LIGHT 3:DARKER
NORMAL
OK
060
Message transfer
ON/OFF
OFF
NG
061
Transfer greeting
CHECK/RECORD/ERASE
CHECK
NG
067
ICM monitor
1:ON 2:OFF
ON
OK
070
FAX pager
ON/OFF
OFF
NG
076
Connecting tone
1:ON 2:OFF
ON
OK
080
Set the default
YES/NO
NO
NG
501
Pause time set
001~600 X 100 msec
050
OK
502
Flash time set
01~99 X 10 msec
70
OK
503
Dial speed set
1:10pps 2:20 pps
10
OK
510
Vox time
1:6sec 2:4sec
6sec
OK
520
CED frequency select
1:2100Hz 2:1100Hz
2100
OK
521
International mode select
1:ON 2:OFF
ON
OK
522
Auto standby select
1:ON 2:OFF
ON
OK
523
Receive equalizer select
1:0km 2:1.8km 3:3.6km 4:7.2km
0km
OK
524
Transmission equalizer select
1:0km 2:1.8km 3:3.6km 4:7.2km
0km
OK
533
Setting the number of times that message transfer is
redialled.
00~99
03
OK
534
Setting of the message transfer/pager call redial
interval
001~999
030
OK
544
Document feed position adjustment value set
01~99 step
---------
OK
550
Memory clear
Press "START".
---------
NG
551
ROM check
Press "START".
---------
NG
552
DTMFsignal tone test
ON/OFF
OFF
NG
553
Monitor on FAX communication select
1:OFF 2:P-B 3:ALL
OFF
OK
554
Modem test
Press "START".
---------
NG
555
Scanner test
Press "START".
---------
NG
556
Motor test
Press "START".
---------
NG
558
LCD test
Press "START".
---------
NG
559
Document jam detection select
1:ON 2:OFF
ON
OK
561
Key test
Press any key.
---------
NG
570
Break % select
1:61% 2:67%
61%
OK
571
ITS auto redial time set
00~99
14
OK
572
ITS auto redial line disconnection time set
001~999 set
030
OK
573
Remote turn-on ring number set
01~99
15
OK
580
TAM continuous tone detection
1:ON/2:OFF
ON
OK
590
FAX auto redial time set
00~99
05
OK
591
FAX auto redial line disconnection time set
001~999
045
OK
592
CNG transmit select
1:OFF/2:ALL/3:AUTO
ALL
OK
593
Time between CED and 300 bps
1:75/2:500/3:1s
75 ms
OK
594
Overseas DIS detection select
1:1st/2:2nd
1st
OK
595
Receive error limit value set
001~999
100
OK
596
Transmit level set
15~00dBm
-10
OK
53
KX-FT25LA
Code
Function
Set Value
Default
Remote setting
598
Receiving Sensitivity
20~48
40
OK
717
Transmit speed select
1:9600/2:7200/3:4800/4:2400bps
9600bps
OK
718
Receive speed select
1:9600/2:7200/3:4800/4:2400bps
9600bps
OK
719
Ringer off in TEL/FAX mode
1:ON/2:OFF
ON
OK
721
Pause tone detect
1:ON/2:OFF
ON
OK
722
Redial tone detect
1:ON/2:OFF
ON
OK
731
CPC mode
1:A / 2:B / 3:OFF
A
OK
763
Friendly reception CNG detection select
1:10S/2:20S/3:30S
20S
OK
771
T1 timer
1:35 sec/2:60 sec
35 sec
OK
774
T4 timer
00~99 X 100ms
00
OK
775
Monitoring of message transfer
1:ON/2:OFF
OFF
OK
815
Sensor check
Press "START".
---------
NG
841
Digital SP-Phone RX & TX check
1: SP-Phone
---------
NG
882
Journal 3
1: START
---------
NG
991
Transmit basic list
1: START
---------
OK
992
Transmit advanced list
1: START
---------
OK
994
Transmit journal report
1: START
---------
OK
999
Transmit service list
1: START
---------
OK
OK : Can set the value by the remote programming feature or print a list.
NG : Cannot set the value.
Note:
Note: Refer to 2.4.4. SERVICE FUNCTION TABLE for descriptions of the individual codes.
For example, the "004 Transmission report mode" set value "1:ERROR/2:ON/3:OFF" number corresponds to the number
dialled.
54
KX-FT25LA
2.3.4.3. Digital Board Section
One of most difficult problems to deal with is when the system will not boot up.
The symptom: No response when the power is turned on. (No LCD display, keys are not accepted.)
Then first thing to do is check the power source, If there is no problem with the power supply unit, then there is a problem with the
digital unit (main board).
As there are many potential causes in this case (ASIC, etc.), it may be difficult to specify what you should check first. If a mistake
is made in the order of checks, a normal part may be determined faulty, wasting both time and money.
Although the tendency is to regard the problem as a serious one (IC malfunction, etc.), usually most cases are caused by solder
faults (poor contact due to a tunnel in the solder, signal short circuit due to solder waste).
Note:
 1. Electrical continuity may have existed at the factory check, but a faulty contact occurred as a result of vibration, etc., during
transport.
 2. Solder waste remaining on the board may get caught under the IC during transport, causing a short circuit.
Before we begin mass production, several hundred trial units are produced at the plant, various tests are applied and any
malfunctions are analyzed. (In past experiences, digital IC (especially SRAM and ROM) malfunctions are extremely rare after
installation in the product.)
This may be repaired by replacing the IC, (ASIC etc.). However, the real cause may not have been an IC malfunction but a
soldering fault instead.
Soldering faults which are difficult to detect with the naked eye are common, particularly for an ASIC and RA (Resistor Array). But
if you have an oscilloscope, you can easily determine the problem site or IC malfunction by checking the main signal lines.
Even if you don´t have such a measuring instrument, by checking each main signal line and resoldering it, in many cases the
problem will be resolved.
An explanation of the main signals (for booting up the unit) is below.
What are the main signals for booting up the unit?
Please refer to the 2.3.4.3.1. Digital Block Diagram.
The ASIC (including the CPU) (IC1) controls all the other digital ICs. When the power is turned on, the ASIC (CPU) retrieves the
operation code stored in the ROM (IC2), then follows the instructions for controlling each IC. All ICs have some inner registers that
are assigned to a certain address.
It is the address bus by which the ASIC (CPU) designates the location inside each IC. And the data bus reads or writes the data
in order to transmit the instructions from the ASIC (CPU) to the ICs.
These signal lines are all controlled by voltages of 5V (H) or 0V (L).
55
KX-FT25LA
2.3.4.3.1. Digital Block Diagram
56
KX-FT25LA
Page of 127