2.3.15. HOW TO CHECK THE RF UNIT
Factory supply only assembled RF unit for base unit and Handset. (Factory does not supply each parts on RF Unit.)
2.3.15.1. HANDSET
 1. Warm up the Marconi Radio Tester for at least 30 minutes to allow internal crystal oscillation to become stable.
 2. Refer to figures right for Handset wire connections.
 3. Disconnect the Handset antenna from the PCB. If you allow the antenna to remain and be a load, the readings will be wrong.
 4. Supply DC 3.9V Handset PCB using a DC power supply.
 5. Solder RF cable to TP-ANT and TP-GND and connect BNC side to Marconi. Use 100 W max. RF Input.
 6. Press TALK, then press "5", "8" and "0" simultaneously.
 7. Press TALK. (Base Unit power is off)
2.3.15.2.  CARRIER FREQUENCY CHECK:
 1. Set Marconi to Transmit Test (press TX TEST button).
 2. Check TX Frequency =926.100 MHz+/-3.0 kHz.
 3. When value if off, adjust VRfreq.
 4. If can´t adjust replace RF Unit.
2.3.15.3.  TRANSMIT POWER CHECK:
 1. Press dBm button on Marconi.
 2. Check Marconi TX Power reading. It should equal
-3.5 dBm+/-4 dBm (-7.5 dBm ~ +1.5 dBm).
 3. When value is over, replace RF Unit.
2.3.15.4. RECEIVING SENSITIVITY CHECK:
 1. Connect audio cable BNC side to AF INPUT in Marconi and other side to TP-AF and TP-GND.
 2. Set Marconi to RX TEST mode. Enter the following setting:
 a. Frequency = 902.100 MHz
 b. Level = 60 dBµV
 c. 
Set Modulation = 1.000 kHz
 d. Level = 6.000 kHz
 3. Press the SINAD button on Marconi until the display shows SINAD value. Press the dB button.
 4. Press the RF GEN and LEVEL button.
 5. Using the VARIABLE knob on Marconi decrease RF GEN LEVEL value until SINAD value is 12 dB.
 6. Check the RF GEN LEVEL. This should be less than
+1 dBµV(+7 dBµVemf). When value is over, replace RF Unit.
101
KX-FPC95 / KX-FPC96
2.3.15.5. SQUELCH CHECK:
 1. Connect scope probe (X1) lead to TP-SQ, negative to TP-VSS and BNC end to scope.
 2. Set scope to the following condition: TIME/DIV = 1 msec, VOLT/DIV = 1 V
 3. Set RF GEN LEVEL to +5 dBµV(+11dBµVemf). Check scope voltage is LOW.
 4. Set RF GEN LEVEL to -17 dBµV(-11dBµVemf). Check scope voltage is HIGH.
 5. When scope voltage is wrong, replace RF Unit.
102
KX-FPC95 / KX-FPC96
2.4. PROGRAMMING AND LISTS
The programming functions are used to program the various features and functions of the machine, and to test the machine.
This facilitates communication between the user and the service man while programming the unit.
2.4.1.  OPERATION
There are 2 basic categories of programming functions, the User Mode and the Service Mode. The Service Mode is further broken
down into the normal and special programs. The normal programs are those listed in the Operating Instructions and are available
to the user. The special programs are only those listed here and not displayed to the user. In both the User and Service Modes,
there are Set Functions and Test Functions. The Set Functions are used to program various features and functions, and the Test
Functions are used to test the various functions. The Set Functions are accessed by entering their code, changing the appropriate
value, then pressing the SET key. The Test Functions are accessed by entering their code and pressing the key listed on the menu.
While programming, to cancel any entry, press the STOP key.
2.4.2.  OPERATION FLOW
103
KX-FPC95 / KX-FPC96
2.4.3. USER MODE (The list below is an example of the SYSTEM SETUP LIST the unit
prints out.)
Note:
The above values are the default values.
104
KX-FPC95 / KX-FPC96
Page of 127
Display

Click on the first or last page to see other KX-FPC95 / KX-FP96 service manuals if exist.