Panasonic KX-FP82RS Service Manual ▷ View online
KX-FP82RS
(for Russia)
Compact Plain Paper FAX
ORDER NO. KMF0009440C3
1
INTRODUCTION
3
1.1.
LCD MASSAGE
3
1.2.
SAFETY PRECAUTIONS
4
1.3.
INSULATION RESISTANCE TEST
4
1.4.
FOR SERVICE TECHNICIANS
4
1.5.
BATTERY CAUTION
4
1.6.
AC CAUTION
5
1.7.
PERSONAL SAFETY PRECAUTIONS
5
1.8.
SERVICE PRECAUTIONS
6
1.9.
FEATURES
7
1.10. SPECIFICATIONS
8
1.11. OPTIONAL ACCESSORIES
8
1.12. TEST CHART
9
1.13. LOCATION OF CONTROLS
11
1.14. CONNECTIONS
13
1.15. INSTALLATION
14
1.16. MAINTENANCE ITEMS AND COMPONENT LOCATIONS
22
2
TROUBLESHOOTING GUIDE
26
2.1.
TROUBLESHOOTING SUMMARY
26
2.2.
USER RECOVERABLE ERRORS
27
2.3.
TROUBLESHOOTING DETAILS
31
2.4.
PROGRAMMING AND LISTS
86
2.5.
TEST FUNCTIONS
99
3
ADJUSTMENTS
106
3.1.
ADJUSTING THE FEEDER PRESSURE
106
4
DISASSEMBLY INSTRUCTIONS
107
4.1.
HOW TO REMOVE THE BOTTOM FRAME
107
4.2.
HOW TO REMOVE THE OPERATION PANEL BLOCK
108
4.3.
HOW TO REMOVE THE OPERATION BOARD AND LCD
109
4.4.
HOW TO REMOVE THE ANALOG, DIGITAL AND
POWER BOARDS AND AC INLET
110
4.5.
HOW TO REMOVE THE MOTOR BLOCK
111
4.6.
HOW TO REMOVE THE SEPARATION ROLLER
113
4.7.
HOW TO REMOVE THE IMAGE SENSOR (CIS)
114
4.8.
HOW TO REMOVE THE TERMAL HEAD
115
4.9.
HOW TO REMOVE THE PLATEN ROLLER, BACK
COVER
116
4.10. HOW TO REMOVE THE PICKUP ROLLER
117
4.11. HOW TO REMOVE THE CASSETTE PLATE
118
4.12. HOW TO REMOVE THE DOCUMENT TRAY
119
4.13. INSTALLATION POSITION OF THE LEAD WIRES
120
5
HOW TO REPLACE THE FLAT PACKAGE IC
121
5.1.
PREPARATION
121
5.2.
FLAT PACKAGE IC REMOVAL PROCEDURE
121
5.3.
FLAT PACKAGE IC INSTALLATION PROCEDURE 122
5.4.
BRIDGE MODIFICATION PROCEDURE
122
6
CIRCUIT OPERATIONS
123
6.1.
CONNECTION DIAGRAM
123
6.2.
GENERAL BLOCK DIAGRAM
124
6.3.
CONTROL SECTION
126
6.4.
FACSIMILE SECTION
136
6.5.
SENSORS AND SWITCHES
151
6.6.
MODEM SECTION
155
6.7.
DESCRIPTION OF BLOCK DIAGRAM IN ANALOG
SECTION
162
6.8.
NCU SECTION
164
6.9.
ITS (Integrated Telephone System) AND MONITOR
SECTION
166
6.10. TAM INTERFACE SECTION
167
6.11. OPERATION BOARD SECTION
169
6.12. LCD SECTION
170
6.13. POWER SUPPLY BOARD SECTION
171
7
TERMINAL GUIDE OF THE IC
エ
S TRANSISTORS AND DIODES
174
8
FIXTURES AND TOOLS
175
9
CABINET, MECHANICAL AND ELECTRICAL PARTS
LOCATION
176
9.1.
OPERATION PANEL SECTION
176
9.2.
UPPER CABINET SECTION
177
9.3.
LOWER/P.C.B. SECTION
180
9.4.
MOTOR SECTION
181
9.5.
ACTUAL SIZE OF SCREWS AND WASHER
181
10 ACCESSORIES AND PACKING MATERIALS
182
11 REPLACEMENT PARTS LIST
183
11.1. CABINET AND ELECTRICAL PARTS
183
11.2. DIGITAL BOARD PARTS
184
11.3. ANALOG BOARD PARTS
186
11.4. OPERATION BOARD PARTS
187
11.5. POWER SUPPLY BOARD PARTS
187
11.6. FIXTURES AND TOOLS
188
12 FOR THE SCHEMATIC DIAGRAMS
189
12.1. MEMO
190
13 PRINTED CIRCUIT BOARD
191
13.1. DIGITAL BOARD: BOTTOM VIEW
191
13.2. DIGITAL BOARD: COMPONENT VIEW
192
13.3. ANALOG BOARD: BOTTOM VIEW
193
13.4. ANALOG BOARD: COMPONENT VIEW
194
13.5. OPERATION BOARD
195
13.6. POWER SUPPLY BOARD
196
14 SCHEMATIC DIAGRAM
197
14.1. DIGITAL BOARD
197
14.2. ANALOG BOARD
198
14.3. OPERATION BOARD
199
14.4. POWER SUPPLY BOARD
200
CONTENTS
Page
Page
2
KX-FP82RS
1.1. LCD MASSAGE
1 INTRODUCTION
3
KX-FP82RS
1.2.
SAFETY PRECAUTIONS
1. Before servicing, unplug the AC power cord to prevent an electric shock.
2. When replacing parts, use only the manufacturer´s recommended components.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
1.3. INSULATION RESISTANCE TEST
1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with an ohmmeter between the jumpered AC plug and each exposed metal cabinet part
(screw heads, control shafts, bottom frame, etc.).
Note: Some exposed parts may be isolated from the chassis by design. These will read infinity.
4. If the measurement is outside the specified limits, there is a possibility of a shock hazard.
1.4. FOR SERVICE TECHNICIANS
ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
1. Cover the plastic part´s boxes with aluminum foil.
2. Ground the soldering irons.
3. Use a conductive mat on the worktable.
4. Do not touch the IC or LSI pins with bare fingers.
1.5. BATTERY CAUTION
CAUTION
Danger of explosion if the battery is replaced incorrectly. Replace only with the same or equivalent type recommended by the
manufacturer. Discard used batteries according to following caution:
manufacturer. Discard used batteries according to following caution:
Disposal of lithium batteries should be performed by permitted, professional disposal firms knowledgeable in state government
federal and local hazardous materials and hazardous waste transportation and disposal requirements.
federal and local hazardous materials and hazardous waste transportation and disposal requirements.
A battery continues to have no transportation limitations as long as it is separated to prevent short circuits and packed in strong
packaging.
packaging.
Commercial firms that dispose of any quantity of lithium cells should have a mechanism in place to account for their ultimate
disposition. This is a good practice for all types of commercial or industrial waste.
disposition. This is a good practice for all types of commercial or industrial waste.
Recommend Type Number:
CR2032 (BAT501) Manufactured by MATSUSHITA
CR2032 (BAT501) Manufactured by SONY
4
KX-FP82RS