Panasonic KX-FP80 Service Manual ▷ View online

KX-FP80
(for U.S.A.)
Compact Plain Paper FAX
ORDER NO. KMF0002391C1
F7
 1 
INTRODUCTION 
3
 1.1. 
SAFETY PRECAUTIONS 
3
 1.2. 
INSULATION RESISTANCE TEST 
3
 1.3. 
FOR SERVICE TECHNICIANS 
3
 1.4. 
BATTERY CAUTION 
3
 1.5. 
AC CAUTION 
4
 1.6. 
PERSONAL SAFETY PRECAUTIONS 
4
 1.7. 
SERVICE PRECAUTIONS 
5
 1.8. 
FEATURES 
6
 1.9. 
SPECIFICATIONS 
7
 1.10. OPTIONAL ACCESSORIES 
7
 1.11. TEST CHART 
8
 1.12. LOCATION OF CONTROLS 
10
 1.13. CONNECTIONS 
12
 1.14. INSTALLATION 
13
 1.15. MAINTENANCE ITEMS AND COMPONENT LOCATIONS
 
21
 2 
TROUBLESHOOTING GUIDE 
25
 2.1. 
TROUBLESHOOTING SUMMARY 
25
 2.2. 
USER RECOVERABLE ERRORS 
26
 2.3. 
TROUBLESHOOTING DETAILS 
30
 2.4. 
PROGRAMMING AND LISTS 
85
 2.5. 
TEST FUNCTIONS 
99
 3 
ADJUSTMENTS 
106
 3.1. 
ADJUSTING THE FEEDER PRESSURE 
106
 4 
DISASSEMBLY INSTRUCTIONS 
107
 4.1. 
HOW TO REMOVE THE BOTTOM FRAME 
107
 4.2. 
HOW TO REMOVE THE OPERATION PANEL BLOCK
 
108
 4.3. 
HOW TO REMOVE THE OPERATION BOARD AND LCD
 
109
 4.4. 
HOW TO REMOVE THE ANALOG, DIGITAL AND
POWER BOARDS AND AC INLET 
110
 4.5. 
HOW TO REMOVE THE MOTOR BLOCK 
111
 4.6. 
HOW TO REMOVE THE SEPARATION ROLLER 
113
 4.7. 
HOW TO REMOVE THE IMAGE SENSOR (CIS) 
114
 4.8. 
HOW TO REMOVE THE TERMAL HEAD 
115
 4.9. 
HOW TO REMOVE THE PLATEN ROLLER, BACK
COVER 
116
 4.10. HOW TO REMOVE THE PICKUP ROLLER 
117
 4.11. HOW TO REMOVE THE CASSETTE PLATE 
118
 4.12. HOW TO REMOVE THE DOCUMENT TRAY 
119
 4.13. INSTALLATION POSITION OF THE LEAD WIRES 
120
 5 
HOW TO REPLACE THE FLAT PACKAGE IC 
121
 5.1. 
PREPARATION 
121
 5.2. 
FLAT PACKAGE IC REMOVAL PROCEDURE 
121
 5.3. 
FLAT PACKAGE IC INSTALLATION PROCEDURE  122
 5.4. 
BRIDGE MODIFICATION PROCEDURE 
122
 6 
CIRCUIT OPERATIONS 
123
 6.1. 
CONNECTION DIAGRAM 
123
 6.2. 
GENERAL BLOCK DIAGRAM 
124
 6.3. 
CONTROL SECTION 
126
 6.4. 
FACSIMILE SECTION 
136
 6.5. 
SENSORS AND SWITCHES 
151
 6.6. 
MODEM SECTION 
155
 6.7. 
DESCRIPTION OF BLOCK DIAGRAM IN ANALOG
SECTION 
162
 6.8. 
NCU SECTION 
164
 6.9. 
ITS (Integrated Telephone System) AND MONITOR
SECTION 
166
 6.10. TAM INTERFACE SECTION 
167
 6.11. OPERATION BOARD SECTION 
169
 6.12. LCD SECTION 
170
 6.13. POWER SUPPLY BOARD SECTION 
171
 7 
FOR THE SCHEMATIC DIAGRAMS 
174
 8 
PRINTED CIRCUIT BOARD 
175
 8.1. 
DIGITAL BOARD: BOTTOM VIEW 
175
 8.2. 
DIGITAL BOARD: COMPONENT VIEW 
176
 8.3. 
ANALOG BOARD: BOTTOM VIEW 
177
 8.4. 
ANALOG BOARD: COMPONENT VIEW 
178
 8.5. 
OPERATION BOARD 
179
 8.6. 
POWER SUPPLY BOARD 
180
 9 
SCHEMATIC DIAGRAM 
181
 9.1. 
DIGITAL BOARD 
181
 9.2. 
ANALOG BOARD 
182
 9.3. 
OPERATION BOARD 
183
 9.4. 
POWER SUPPLY BOARD 
184
 10 TERMINAL GUIDE OF THE IC
·
S TRANSISTORS AND DIODES
 
185
 11 FIXTURES AND TOOLS 
186
 12 CABINET, MECHANICAL AND ELECTRICAL PARTS
LOCATION 
187
 12.1. OPERATION PANEL SECTION 
187
 12.2. UPPER CABINET SECTION 
188
 12.3. LOWER/P.C.B. SECTION 
191
 12.4. MOTOR SECTION 
192
 12.5. ACTUAL SIZE OF SCREWS AND WASHER 
192
 13 ACCESSORIES AND PACKING MATERIALS 
193
 14 REPLACEMENT PARTS LIST 
194
 14.1. CABINET AND ELECTRICAL PARTS 
194
 14.2. DIGITAL BOARD PARTS 
195
 14.3. ANALOG BOARD PARTS 
197
 14.4. OPERATION BOARD PARTS 
199
 14.5. POWER SUPPLY BOARD PARTS 
199
 14.6. FIXTURES AND TOOLS 
200
 14.7. SERVICE PART NO. FOR OPTIONAL ACCESSORIES
(SALES ITEM) 
200
CONTENTS
 Page 
Page
2
KX-FP80
1 INTRODUCTION
1.1.  SAFETY PRECAUTIONS
 1. Before servicing, unplug the AC power cord to prevent an electric shock.
 2. When replacing parts, use only the manufacturer´s recommended components.
 3. Check the condition of the power cord. Replace if wear or damage is evident.
 4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
 5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
1.2. INSULATION RESISTANCE TEST
 1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
 2. Turn on the power switch.
 3. Measure the resistance value with an ohmmeter between the jumpered AC plug and each exposed metal cabinet part
(screw heads, control shafts, bottom frame, etc.).
Note: Some exposed parts may be isolated from the chassis by design. These will read infinity.
 4. If the measurement is outside the specified limits, there is a possibility of a shock hazard.
1.3. FOR SERVICE TECHNICIANS
ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
 1. Cover the plastic part´s boxes with aluminum foil.
 2. Ground the soldering irons.
 3. Use a conductive mat on the worktable.
 4. Do not touch the IC or LSI pins with bare fingers.
1.4.  BATTERY CAUTION
CAUTION
Danger of explosion if the battery is replaced incorrectly. Replace only with the same or equivalent type recommended by the
manufacturer. Discard used batteries according to following caution:
Disposal of lithium batteries should be performed by permitted, professional disposal firms knowledgeable in state government
federal and local hazardous materials and hazardous waste transportation and disposal requirements.
A battery continues to have no transportation limitations as long as it is separated to prevent short circuits and packed in strong
packaging.
Commercial firms that dispose of any quantity of lithium cells should have a mechanism in place to account for their ultimate
disposition. This is a good practice for all types of commercial or industrial waste.
Recommend Type Number:
CR2032 (BAT501) Manufactured by MATSUSHITA
CR2032 (BAT501) Manufactured by SONY
3
KX-FP80
1.5. AC CAUTION
For safety, before closing the lower cabinet, please make sure of the following precautions.
 1. The earth lead is fixed with the screw.
 2. The AC connector is connected properly.
 3. Wrap the earth lead around the core 3 times.
1.6. PERSONAL SAFETY PRECAUTIONS
1.6.1. MOVING SECTIONS OF THE UNIT
Be careful not to let your hair, clothes, fingers, accessories, etc., become caught in any moving sections of the unit.
The moving sections of the unit are the rollers and a gear. There is a separation roller and a document feed roller which are rotated
by the document feed motor. A gear rotates the two rollers. Be careful not to touch them with your hands, especially when the unit
is operating.
4
KX-FP80
Page of 127
Display

Panasonic KX-FP80 Service Manual ▷ Download

  • DOWNLOAD Panasonic KX-FP80 Service Manual ↓ Size: 4.93 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic KX-FP80 in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic KX-FP80 Fax. Information contained in Panasonic KX-FP80 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.