DOWNLOAD Panasonic KX-FP363UA Service Manual ↓ Size: 5.23 MB | Pages: 127 in PDF or view online for FREE

Model
KX-FP363UA
Pages
127
Size
5.23 MB
Type
PDF
Document
Service Manual
Brand
Device
Fax / COMPACT PLAIN PAPER FAX WITH ANSWERING SYSTEM
File
kx-fp363ua.pdf
Date

Panasonic KX-FP363UA Service Manual ▷ View online

1. Platen roller
2. Left margin / Top margin
3. Thermal head 1 dot
4. Use this test pattern to confirm the torque limiter for ink
film and platen roller timing
6.3.3. PRINT TEST PATTERN
53
KX-FP363UA
6.4. REMOTE PROGRAMMING
If, after the call is connected, the customer describes the situation and it is determined that the problem can be corrected by
making parameter changes, this function makes it possible to change parameters such as the user code and service code from
another fax (using DTMF tones). Therefore, travel to the customer´s location is not required. However, it is not possible to
change all the parameters remotely (PROGRAM MODE TABLE (P.55)). The function used to accomplish this is remote
programming.
First, in order to check the current status of the service code parameter, print out the setup list (code: 991) and the service list
(code: 999) from the customer´s fax machine.
Based on this, the parameters for the desired codes can be changed.
The procedure for changing and listing parameters is described on ENTERING THE REMOTE PROGRAMMING MODE AND
CHANGING SERVICE CODES 
(P.54). Also, before exiting the remote programming mode, it is advisable to obtain a new list
to confirm that the changes were made correctly.
Hint:
Since the connected telephone is in use during the remote programming mode, it may be helpful to ask the customer to switch
to the speakerphone. This frees the customer from the need to remain right next to the fax while you are making parameter
settings. When finished, inform the customer. Also note that in very noisy locations where the DTMF tones are not audible, the
remote programming function will not work.
6.4.1. ENTERING THE REMOTE PROGRAMMING MODE AND CHANGING SERVICE
CODES
CROSS REFERENCE:
PROGRAM MODE TABLE (P.55)
54
KX-FP363UA
6.4.2. PROGRAM MODE TABLE
Code
Function
Set Value
Default
Remote
Setting
001
Set date and time
mm/dd/yy hh:mm
Jan/01/2003
NG
002
Your logo
---------
None
NG
003
Your FAX number
---------
None
NG
004
Print sending mode
1:ERROR/ 2:ON / 3:OFF
OFF
OK
006
FAX ring count
1~9
2
OK
TAD/FAX ring count
1:1~4 / 2:TOLL SAVER / 3: RINGER
OFF
2
OK
010
Recording time
1:VOX / 2:1-9 MIN
VOX
OK
011
Remote TAD ID
ON / OFF
ID=111
NG
013
Dialing mode
1:TONE / 2:PULSE
PULSE
OK
017
Ringer Pattern
A / B / C
A
NG
022
Journal auto print
1:ON / 2:OFF
ON
OK
023
Overseas mode
1:ON / 3:OFF
OFF
OK
025
Delayed transmission
1:ON / 2:OFF
OFF
NG
026
Auto caller ID list
1:ON / 2:OFF
ON
OK
034
Quick scan
1:ON / 2:OFF
OFF
OK
036
RCV reduction
1:72% / 2:86% / 3:92% / 4:100
92%
OK
039
LCD contrast
NORMAL / DARKER
NORMAL
NG
041
FAX activation code
ON / OFF
ON ID=*#9
NG
042
Message alert
1:ON / 2:OFF
OFF
OK
043
REC. time alert
1:ON / 2:OFF
OFF
OK
044
Memory receive alert
1:ON / 2:OFF
ON
OK
046
Friendly receive
1:ON / 2:OFF
ON
OK
047
Voice guidance
1:ERROR/2:ON/3:OFF
ON
OK
048
Language
1:English / 2:Russian
Russian
OK
051
Mailbox 1 Password
---------
---------
NG
052
Mailbox 2 Password
---------
---------
NG
054
Greeting MSG. REC. time
1:16s / 2:60s
16s
OK
055
Mailbox 1 Greeting
1:CHECK / 2:RECORD / 3:ERASE
CHECK
NG
056
Mailbox 2 Greeting
1:CHECK / 2:RECORD / 3:ERASE
CHECK
NG
058
Original setting
1:NORMAL / 2:LIGHT / 3:DARKER
NORMAL
OK
060
Message transfer
1:ON / 2:OFF
OFF
NG
061
Transfer greeting
1:CHECK / 2:RECORD / 3:ERASE
CHECK
NG
067
ICM monitor
1:ON / 2:OFF
ON
OK
068
ECM selection
1:ON / 2:OFF
ON
OK
070
Pager call
1:ON / 2:OFF
OFF
NG
076
Connecting tone
1:ON / 2:OFF
ON
OK
077
Auto answer mode
1:TAD/FAX 2: FAX Only
TAD/FAX
OK
080
Set default
1:YES / 2:NO
NO
NG
501
Pause time set
001~600 x 100msec
030msec
OK
502
Flash time
01~99 x 10ms
85ms
OK
503
Dial speed
1:10pps / 2:20pps
10pps
OK
510
Vox time
1:6sec / 2:4sec
6sec
OK
511
Vox sense
1:High / 2:Low
High
OK
514
Bell detection time
1~9 x 100msec
6 x 100msec
OK
520
CED frequency select
1:2100Hz / 2:1100Hz
2100Hz
OK
521
International mode select
1:ON / 2:OFF
ON
OK
522
Auto standby select
1:ON / 2:OFF
ON
OK
523
Receive equalizer select
1:0km / 2:1.8km / 3:3.6km / 4:7.2km
0km
OK
524
Transmission equalizer select
1:0km / 2:1.8km / 3:3.6km / 4:7.2km
0km
OK
533
Setting the number of times that message transfer is
redialed.
00~99
03
OK
534
Setting of the message transfer/pager call redial
interval
001~999
065
OK
544
Document feed position adjustment value set
1:3mm / 2:4mm / 3:5mm / 4:6mm /
5:7mm
5mm
OK
550
Memory clear
---------
---------
NG
551
ROM check
---------
---------
NG
552
DTMF signal tone test
1:ON / 2:OFF
OFF
OK
553
Monitor on FAX communication
1:OFF / 2:Phase B / 3:ALL
OFF
OK
554
Modem test
---------
---------
NG
555
Scanner test
---------
---------
NG
556
Motor test
---------
---------
NG
557
LED test
---------
---------
NG
558
LCD test
---------
---------
NG
55
KX-FP363UA
Code
Function
Set Value
Default
Remote
Setting
559
Document jam detection
1:ON / 2:OFF
ON
OK
561
Key test
---------
---------
NG
570
Break % select
1:61% / 2:67%
61%
OK
571
ITS auto redial time set
00~99
03
OK
572
ITS auto redial line disconnection time set
001~999sec
065sec
OK
573
Remote turn-on ring number
01~99
10
OK
580
TAM continuous tone detection
1:ON / 2:OFF
ON
OK
590
FAX auto redial time set
00~99
03
OK
591
FAX auto redial line disconnection time set
001~999sec
065sec
OK
592
CNG transmit select
1:OFF / 2:ALL / 3:AUTO
ALL
OK
593
Time between CED and 300 bps
1:75ms / 2:500ms / 3:1sec
75ms
OK
594
Overseas DIS detection
1:1st / 2:2nd
1st
OK
595
Receive error limit value
001~999
100
OK
596
Transmit level set
-15~00dBm
-11dBm
OK
598
Receiving Sensitivity
20~48
-43
OK
599
ECM frame size
1: 256 byte / 2: 64 byte
256 byte
OK
710
Memory clear except History data
---------
---------
NG
717
Transmit speed select
1:14400 / 2:12000 / 3:9600/ 4:7200/
5:4800/ 6:2400
14400bps
OK
718
Receive speed select
1:14400 / 2:12000 / 3:9600/ 4:7200/
5:4800/ 6:2400
14400bps
OK
722
Redial tone detect
1:ON / 2:OFF
ON
OK
731
CPC mode
1:A / 2:B / 3:OFF
A
OK
732
Auto disconnect
1:350ms / 2:1800ms / 3:OFF
350ms
OK
745
Power on film feed
1:ON / 2:OFF
ON
OK
763
CNG detect time for friendly reception
1:10s / 2:20s / 3:30s
30s
OK
771
T1 timer
1:35s / 2:60s
35s
OK
774
T4 timer
00~99 × 100ms
00ms
OK
775
Monitoring of message transfer
1:ON / 2:OFF
OFF
OK
784
Voice prompt
1:Start
---------
NG
815
Sensor & VOX test
---------
---------
NG
852
Print test pattern
---------
---------
NG
853
Top margin
1~9
5
OK
874
DTMF ON time
060~200 ms
090ms
OK
875
DTMF OFF time
060~200 ms
085ms
OK
880
History list
1:Start
---------
NG
881
Journal 2
---------
---------
NG
882
Journal 3
---------
---------
NG
991
Setup list
1:Start
---------
OK
994
Journal list
1:Start
---------
OK
995
Journal 2 list
1:Start
---------
OK
996
Journal 3 list
1:Start
---------
OK
998
History list
1:Start
---------
OK
999
Service list
1:Start
---------
OK
OK means "can set".
NG means "can not set".
Note:
Refer to SERVICE FUNCTION TABLE (P.49) for descriptions of the individual codes.
Example:
If you want to set value in the "004 Transmission report mode", press the dial key number 1,2 or 3 corresponding to the Set
Value you want to select. (1:ERROR/2:ON/3:OFF)
56
KX-FP363UA
Page of 127
Display

Click on the first or last page to see other KX-FP363UA service manuals if exist.