1.3. SAFETY PRECAUTIONS
 1. Before servicing, unplug the AC power cord to prevent an electric shock.
 2. When replacing parts, use only the manufacturer´s recommended components.
 3. Check the condition of the power cord. Replace if wear or damage is evident.
 4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
 5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
1.4. INSULATION RESISTANCE TEST
 1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
 2. Turn on the power switch.
 3. Measure the resistance value with an ohmmeter between the jumpered AC plug and each exposed metal cabinet part
(screw heads, control shafts, bottom frame, etc.).
Note: Some exposed parts may be isolated from the chassis by design. These will read infinity.
 4. If the measurement is outside the specified limits, there is a possibility of a shock hazard.
1.5. FOR SERVICE TECHNICIANS
ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
 1. Cover the plastic part´s boxes with aluminum foil.
 2. Ground the soldering irons.
 3. Use a conductive mat on the worktable.
 4. Do not touch the IC or LSI pins with bare fingers.
1.6. BATTERY CAUTION
CAUTION
There is a danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type
recommended by the manufacturer. Dispose used batteries according to the manufacturerís instructions:
The lithium battery is a critical component (type No. CR-2032/V9A). Please observe for the proper polarity and exact location
when replacing and soldering the replacement battery.
7
KX-FL403UA
1.7. AC CAUTION
For safety, before closing the lower cabinet, please make sure of the following precautions.
 1. The earth lead is fixed with the screw.
 2. The AC connector is connected properly.
 3. Wind the earth lead around the core as shown in below illustration.
 4. Wind the earth AC around the core as shown in below illustration.
1.8. PERSONAL SAFETY PRECAUTIONS
1.8.1. MOVING SECTIONS OF THE UNIT
Be careful not to let your hair, clothes, fingers, accessories, etc., become caught in any moving sections of the unit.
The moving sections of the unit are the rollers and a gear. There is a separation roller and a document feed roller which are rotated
by the document feed motor. A gear rotates the two rollers. Be careful not to touch them with your hands, especially when the unit
is operating.
8
KX-FL403UA
1.8.2. LIVE ELECTRICAL SECTIONS
All the electrical sections of the unit supplied with AC power by the AC power cord are live.
Never disassemble the unit for service with the AC power supply plugged in.
CAUTION:
AC voltage is supplied to the primary side of the power supply unit. Therefore, always unplug the AC power cord before
disassembling for service.
1.8.3. LASER BEAM AND FUSER UNIT SECTION
     • 
• 
• 
• 
The printer of this unit utilizes a laser. Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
     • 
• 
• 
• 
The fuser unit is inside of the unit and gets hot. Do not touch it when removing the jammed paper or cleaning the lower glass.
9
KX-FL403UA
1.9. SERVICE PRECAUTIONS
1.9.1. PRECAUTIONS TO PREVENT DAMAGE FROM STATIC ELECTRICITY
Electrical charges accumulate on a person. For instance, clothes rubbing together can damage electric elements or change their
electrical characteristics. In order to prevent static electricity, touch a metallic part that is grounded to release the static electricity.
Never touch the electrical sections such as the power supply unit, etc.
1.10. FOR BEST PERFORMANCE
     • 
• 
• 
• 
To extend the life of the drum unit, the unit should never be turned OFF immediately after printing. Leave the power turned ON
for a minimum of 30 minutes after printing.
     • 
• 
• 
• 
In the printing process, heat is used to fuse toner onto the page. As a result, it is normal for the machine to produce an odor
during and shortly after printing. Be sure to use this unit in an area with proper ventilation.
     • 
• 
• 
• 
Do not cover slots or openings on the unit. Inspect the air circulation vents regularly and remove any dust build-up with a
vacuum cleaner.
     • 
• 
• 
• 
If the inside of the unit is dirty, clean it with a soft and dry cloth (especially the lower glass).
     • 
• 
• 
• 
When replacing the toner cartridge or drum unit, do not allow dust, water, or liquids to come in contact with the drum. This may
affect print quality.
     • 
• 
• 
• 
Store unused paper in the original packaging, in a cool and dry place. Not doing so may affect print quality.
     • 
• 
• 
• 
Do not place the unit in an area where the paper tray may be obstructed (i.e., by a wall,etc.).
     • 
• 
• 
• 
Keep the air circulation vents away from walls etc.more than 50 mm (1 31 / ") to let the unit cool down.