DOWNLOAD Panasonic DMC-LS80P / DMC-LS80PC / DMC-LS80PL / DMC-LS80E / DMC-LS80EB / DMC-LS80EE / DMC-LS80EF / DMC-LS80EG / DMC-LS80GC / DMC-LS80GK / DMC-LS80GN Service Manual ↓ Size: 2.4 MB | Pages: 48 in PDF or view online for FREE

Model
DMC-LS80P DMC-LS80PC DMC-LS80PL DMC-LS80E DMC-LS80EB DMC-LS80EE DMC-LS80EF DMC-LS80EG DMC-LS80GC DMC-LS80GK DMC-LS80GN
Pages
48
Size
2.4 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / DIGITAL CAMERA
File
dmc-ls80p-dmc-ls80pc-dmc-ls80pl-dmc-ls80e-dmc-ls80.pdf
Date

Panasonic DMC-LS80P / DMC-LS80PC / DMC-LS80PL / DMC-LS80E / DMC-LS80EB / DMC-LS80EE / DMC-LS80EF / DMC-LS80EG / DMC-LS80GC / DMC-LS80GK / DMC-LS80GN Service Manual ▷ View online

ORDER NO. DSC0802001CE
B26
Digital Camera
Model No.
DMC-LS80P
DMC-LS80PC
DMC-LS80PL
DMC-LS80E
DMC-LS80EB
DMC-LS80EE
DMC-LS80EF
DMC-LS80EG
DMC-LS80GC
DMC-LS80GK
DMC-LS80GN
Vol. 1
Colour
(S).............Silver Type (except DMC-LS80EF)
(K).............Black Type (except DMC-LS80EB/GK/GN)
(P).............Pink Type (except DMC-LS80EF/PC/GC/GN)
2
1 Safety Precautions
1.1.
General Guidelines
1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
 in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essen-
tial that these critical parts should be replaced with manu-
facturer’s specified parts to prevent X-RADIATION,
shock, fire, or other hazards. Do not modify the original
design without permission of manufacturer.
2. An Isolation Transformer should always be used during
the servicing of AC Adaptor whose chassis is not isolated
from the AC power line. Use a transformer of adequate
power rating as this protects the technician from acci-
dents resulting in personal injury from electrical shocks. It
will also protect AC Adaptor from being damaged by acci-
dental shorting that may occur during servicing.
3. When servicing, observe the original lead dress. If a short
circuit is found, replace all parts which have been over-
heated or damaged by the short circuit.
4. After servicing, see to it that all the protective devices
such as insulation barriers, insulation papers shields are
properly installed.
5. After servicing, make the following leakage current
checks to prevent the customer from being exposed to
shock hazards.
1.2.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed metal-
lic cabinet part on the equipment such as screwheads,
connectors, control shafts, etc. When the exposed metal-
lic part has a return path to the chassis, the reading
should be between 1 M
Ω and 5.2 MΩ. When the exposed
metal does not have a return path to the chassis, the
reading must be infinity.
1.3.
Leakage Current Hot Check
(See Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5 k
Ω, 10 W resistor, in parallel with a 0.15 μF
capacitor, between each exposed metallic part on the set
and a good earth ground, as shown in Figure 1.
3. Use an AC voltmeter, with 1 k
Ω/V or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt-
age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 or equiva-
lent) may be used to make the hot checks, leakage cur-
rent must not exceed 1/2 mA. In case a measurement is
outside of the limits specified, there is a possibility of a
shock hazard, and the equipment should be repaired and
rechecked before it is returned to the customer.
Figure. 1
3
1.4.
How to Discharge the Capacitor on Flash Top PCB
CAUTION:
1. Be sure to discharge the capacitor on FLASH TOP PCB.
2. Be careful of the high voltage circuit on FLASH TOP PCB when servicing.
[Discharging Procedure]
1. Refer to the disassemble procedure and Remove the necessary parts/unit.
2. Put the insulation tube onto the lead part of Resistor (ERG5SJ102:1k
Ω /5W).
(an equivalent type of resistor may be used.)
3. Put the resistor between both terminals of capacitor on FLASH TOP PCB for approx. 5 seconds.
4. After discharging confirm that the capacitor voltage is lower than 10V using a voltmeter.
Fig. F1
4
2 Warning
2.1.
Prevention of Electrostatic Discharge (ESD) to Electrostatically
Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Elec-
trostatically Sensitive (ES) Devices.
The following techniques should be used to help reduce the incidence of component damage caused by electrostatic discharge
(ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as alumi-
num foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an antistatic solder removal device. Some solder removal devices not classified as "antistatic (ESD protected)" can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or compara-
ble conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
CAUTION :
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the
brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) suf-
ficient to damage an ES device).
Page of 48
Display

Panasonic DMC-LS80P / DMC-LS80PC / DMC-LS80PL / DMC-LS80E / DMC-LS80EB / DMC-LS80EE / DMC-LS80EF / DMC-LS80EG / DMC-LS80GC / DMC-LS80GK / DMC-LS80GN Service Manual ▷ Download

  • DOWNLOAD Panasonic DMC-LS80P / DMC-LS80PC / DMC-LS80PL / DMC-LS80E / DMC-LS80EB / DMC-LS80EE / DMC-LS80EF / DMC-LS80EG / DMC-LS80GC / DMC-LS80GK / DMC-LS80GN Service Manual ↓ Size: 2.4 MB | Pages: 48 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic DMC-LS80P / DMC-LS80PC / DMC-LS80PL / DMC-LS80E / DMC-LS80EB / DMC-LS80EE / DMC-LS80EF / DMC-LS80EG / DMC-LS80GC / DMC-LS80GK / DMC-LS80GN in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic DMC-LS80P / DMC-LS80PC / DMC-LS80PL / DMC-LS80E / DMC-LS80EB / DMC-LS80EE / DMC-LS80EF / DMC-LS80EG / DMC-LS80GC / DMC-LS80GK / DMC-LS80GN Digital Camera. Information contained in Panasonic DMC-LS80P / DMC-LS80PC / DMC-LS80PL / DMC-LS80E / DMC-LS80EB / DMC-LS80EE / DMC-LS80EF / DMC-LS80EG / DMC-LS80GC / DMC-LS80GK / DMC-LS80GN Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.