6 Service Mode
6.1.
Error Code Memory Function
1. General description
This unit is equipped with history of error code memory function, and can be memorized 32 error codes in sequence from the
latest. When the error is occurred more than 32, the oldest error is overwritten in sequence.
The error code is not memorized when the power supply is shut down forcibly (when the unit is powered on by the battery, the
battery is pulled out) because the error code is memorized to FLASH ROM when the unit is powered off.
2. How to display
The error code can be displayed by the following procedure:
Before perform the error code memory function, connect the AC adaptor or insert the battery, and insert the SD card.
• 1. The temporary cancellation of factory setting:
Set the mode dial to “ [ Normal picture mode ] (Red camera mark)”.
While keep pressing [ Optical Image Stabilizer Button ] and “[ UP ] of Cross key” simultaneously, turn the Power on.
• 2. The display of error code:
Press [ Optical Image Stabilizer Button ], [ MENU ] and “[ LEFT ] of Cross key” simultaneously with the step 1 condition.
The display is changed as shown below when the above buttons is pressed simultaneously.
Normal display 
→ Error code display → Operation history display → Normal display → .....
Example of Error Code Display
• 3. The change of display:
The error code can be memorized 32 error codes in sequence, however it is displayed 5 errors on the LCD.
Display can be changed by the following procedure:
“[ UP ] or [ DOWN ] of Cross key” : It can be scroll up or down one.
“[ LEFT ] or [ RIGHT ] of Cross key” : It can be display last 5 error or another 5 error.
• 4. How to read the error code:
One error code is displayed for 8 bit, the contents of error codes is indicated the table as shown below.
14
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4 bits Low 4 bits
Check point (Lower)
LENS
Lens drive
OIS
1800
1000 
PSD (X) error. Hall element (X axis) position detect error in OIS unit.
OIS Unit
2000 
PSD (Y) error. Hall element (Y axis) position detect error in OIS unit.
OIS Unit
3000 
GYRO (X) error. Gyro (IC7102: X axis) detect error on Main P.C.B..
IC7102 (Gyro element) or IC6001 (VENUS PLUS)
4000 
GYRO (Y) error. Gyro (IC7101: Y axis) detect error on Main P.C.B..
IC7101 (Gyro element) or IC6001 (VENUS PLUS)
5000 
MREF error (Reference voltage error).
IC7002 (LENS drive) or IC6001 (VENUS PLUS)
6000 
Drive voltage (X) error.
VENUS PLUS AD value error, LENS Unit, LENS flex breaks etc.
7000 
Drive voltage (Y) error.
VENUS PLUS AD value error, LENS Unit, LENS flex breaks etc.
C.B./Zoom
0100
HP Low detect error (C.B. encoder (full retract) always Low detect).
FP9001-(2, 10) signal line or IC6001 (VENUS PLUS)
0200
HP High detect error (C.B. encoder (full retract) always High detect).
FP9001-(2, 10) signal line or IC6001 (VENUS PLUS)
0300
ENC1 detect error (C.B. motor encoder detect error).
FP9001-(2) signal line or IC6001 (VENUS PLUS)
0400
ENC2 detect error (C.B. motor encoder detect error).
FP9001-(10) signal line or IC6001 (VENUS PLUS)
Zoom
0010
HP Low detect error (Zoom encoder always Low detect error).
0020
HP High detect error (Zoom encoder always High detect error).
0030
ENC1 detect error (Zoom encoder detect error).
0040
ENC2 detect error (Zoom encoder detect error).
Focus
0001
HP Low detect error (Focus encoder always Low detect error).
FP9001-(27) signal line or IC6001 (VENUS PLUS)
0002
HP High detect error (Focus encoder always High detect error).
FP9001-(27) signal line or IC6001 (VENUS PLUS)
Lens
1801
0000
Power ON time out error.
Lens drive system
1802
0000
Power OFF time out error.
Lens drive system
Adj.History
OIS
1900
2000
OIS adj. Yaw direction amplitude error (small)
3000
OIS adj. Pitch direction amplitude error (small)
4000
OIS adj. Yaw direction amplitude error (large)
5000
OIS adj. Pitch direction amplitude error (large)
6000
OIS adj. MREF error
7000
OIS adj. time out error
8000
OIS adj. Yaw direction off set error
9000
OIS adj. Pitch direction off set error
A000
OIS adj. Yaw direction gain error
B000
OIS adj. Pitch direction gain error
C000
OIS adj. Yaw direction position sensor error
D000
OIS adj. Pitch direction position sensor error
E000
OIS adj. other error
HARD
FLASH ROM
(EEPROM 
Area)
FLASH ROM
(EEPROM 
Area)
2B00
0001
EEPROM read error
IC6002 (FLASH ROM)
0002
EEPROM write error
IC6002 (FLASH ROM)
SYSTEM
RTC
2C00
0001
SYSTEM IC initialize error
Communication between IC6001 (VENUS PLUS) and IC9101 (SYSTEM)
15
• 5. How to returned to Normal Display:
Turn the power off and on, to exit from Error code display mode.
NOTE:
The error code can not be initialized.
SOFT
CPU
Reset
3000
0001
|
0007
NMI reset
Non Mask-able Interrupt
(30000001-30000007 are caused by factors)
Card
Card
3100
0001
Card logic error
SD card data line or IC6001 (VENUS PLUS)
0002
Card physical error
SD card data line or IC6001 (VENUS PLUS)
0004
Write error
SD card data line or IC6001 (VENUS PLUS)
3900
0005
Format error
CPU, 
ASIC hard
Stop
3800
0001
Camera task finish process time out.
Communication between Lens system and IC6001 (VENUS PLUS)
0002
Camera task invalid code error.
IC6001 (VENUS PLUS)
0100
File time out error in recording motion image
IC6001 (VENUS PLUS)
0200
File data send error in recording motion image
IC6001 (VENUS PLUS)
Operation
Power on
3B00
0000
FLASHROM processing early period of camera during movement.
Zoom
Zoom
3C00
0000
I do not complete zoom lens processing
Zoom lens
3500
0000
I jumped into dummy processing
(0-7bit : command, 8-15bit : Status)
3501
0000
Though record preprocessing is necessary, it is not called.
3502
0000
Though record preprocessing is necessary, it is not completed.
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4 bits Low 4 bits
Check point (Lower)
16
6.2.
Confirmation of Firmware Version
The Firmware version can be confirmed by ordering the following steps:.
• Step 1. The temporary cancellation of factory setting:
Set the mode dial to “[ Normal picture mode ] (Red camera mark)”.
Insert the SD memory card which has a few photo data.
While keep pressing [ Optical Image Stabilizer ] and “[ UP ] of Cross key” simultaneously, then turn the power on.
• Step 2. Confirm the version:
Set the mode dial to “[ Playback ]” and then press [ DISPLAY ] to switch to LCD with indication. (Fig. A)
Press [ Optical Image Stabilizer ] and “[ DOWN ] of Cross key” simultaneously. (No need to keep pressing.)
(The version information is displayed on the LCD with green colour letters.) (Fig. B) 
CAUTION:
The version information does not display if the LCD has switched to LCD with indication already.
In this case, press [ DISPLAY ] to switch to LCD with indication.
<Point>
• The firmware version and EEPROM version can be confirmed with the information (1).
• The information (2), (3) are just reference.