Panasonic DMC-FS5P / DMC-FS5PC / DMC-FS5PL / DMC-FS5PR / DMC-FS5E / DMC-FS5EB / DMC-FS5EE / DMC-FS5EF / DMC-FS5EG / DMC-FS5GC / DMC-FS5GK / DMC-FS5GN / DMC-FS5GT / DMC-FS5GJ Service Manual ▷ View online
29
8.5.3.
Assembly for the 1st Lens Frame
Unit and Drive/Direct/Fixed Frame
Unit
Unit and Drive/Direct/Fixed Frame
Unit
8.5.4.
Assembly for the 2nd Lens Frame
Move Unit and Drive/Direct/Fixed
Frame/1st Lens Frame Unit
Move Unit and Drive/Direct/Fixed
Frame/1st Lens Frame Unit
30
8.5.5.
Assembly for the Master Flange
Unit and Drive/Direct/Fixed Frame/
1st Lens Frame/2nd Lens Frame
Move Unit
Unit and Drive/Direct/Fixed Frame/
1st Lens Frame/2nd Lens Frame
Move Unit
8.6.
Removal of the CCD Unit
To prevent the CCD unit from catching the dust and dirt, do not
remove the CCD unit except for replacing.
remove the CCD unit except for replacing.
31
8.7.
Removal of the Focus Motor
Unit
Unit
8.8.
The Applyment of Grease
Method
Method
The grease apply point of lens unit are as follows.
Apply grease additionally in the specified position if necessary.
When the grease is applied, use a toothpick and apply thinly.
Apply grease additionally in the specified position if necessary.
When the grease is applied, use a toothpick and apply thinly.
• Lead screw/Guide pole L,S/Fasten groove of nut
- Grease: RFKZ0472
- Amount of apply: 2 - 4 mg
- Amount of apply: 2 - 4 mg
32
9 Measurements and Adjustments
9.1.
Matrix Chart for Replaced Part and Necessary Adjustment
The relation between Replaced part and Necessary Adjustment is shown in the following table.
When concerned part is replaced, be sure to achieve the necessary adjustment(s).
As for Adjustment condition/procedure, consult the “Adjustment Manual” which is available in Adjustment software.
The Adjustment software is available at “TSN Website”, therefore, access to “TSN Website” at “Support Information from NWBG/
VDBG-PAVC”.
NOTE:
When concerned part is replaced, be sure to achieve the necessary adjustment(s).
As for Adjustment condition/procedure, consult the “Adjustment Manual” which is available in Adjustment software.
The Adjustment software is available at “TSN Website”, therefore, access to “TSN Website” at “Support Information from NWBG/
VDBG-PAVC”.
NOTE:
After adjustments have been terminated, make sure to achieve “INITIAL SETTINGS”.
*1: This adjustment is necessary, not only replacing CCD unit but also removing it from the lens unit.
NOTE:
*There is no LCD adjustment in this model.
Replaced Part
Adjustment Item
Main P.C.B.
VENUS
(IC6001)
Flash-ROM
(IC6002)
Lens Part
(Excluding
CCD)
CCD Unit
Camera
Section
Section
OIS hall element adjustment
(OIS)
(OIS)
O
O
O
O
-
Back focus adjustment
(BF)
(BF)
O
O
O
O
O
*1
Shutter adjustment
(SHT)
(SHT)
O
O
O
O
O
ISO sensitivity adjustment
(ISO)
(ISO)
O
O
O
O
O
AWB adjustment
High brightness coloration inspection
(WBL)
High brightness coloration inspection
(WBL)
O
O
O
O
O
CCD white scratch compensation
(WKI)
(WKI)
O
O
O
-
O
*1
CCD black scratch compensation
(BKI)
(BKI)
O
O
O
-
O
*1
Click on the first or last page to see other DMC-FS5P / DMC-FS5PC / DMC-FS5PL / DMC-FS5PR / DMC-FS5E / DMC-FS5EB / DMC-FS5EE / DMC-FS5EF / DMC-FS5EG / DMC-FS5GC / DMC-FS5GK / DMC-FS5GN / DMC-FS5GT / DMC-FS5GJ service manuals if exist.