Panasonic DMC-FS35EB / DMC-FS35EE / DMC-FS35EF / DMC-FS35EG / DMC-FS35EP / DMC-FH25P / DMC-FH25PC / DMC-FH25PR / DMC-FH25PU / DMC-FH25GA / DMC-FH25GC / DMC-FH25GF / DMC-FH25GH / DMC-FH25GK / DMC-FH25GN / DMC-FH25GT / DMC-FH24P Service Manual ▷ View online
9
3.4.
How to Define the Model Suffix (NTSC or PAL model)
There are eight kinds of DMC-FS35, FH25, FH24, regardless of the colours.
• a) DMC-FH24P
• b) DMC-FH25P/PC
• c) DMC-FS35EB/EF/EG/EP
• d) DMC-FS35EE
• e) DMC-FH25GT
• f) DMC-FH25GK
• g) DMC-FH25GN
• h) DMC-FH25PR/PU/GA/GC/GF/GH
• b) DMC-FH25P/PC
• c) DMC-FS35EB/EF/EG/EP
• d) DMC-FS35EE
• e) DMC-FH25GT
• f) DMC-FH25GK
• g) DMC-FH25GN
• h) DMC-FH25PR/PU/GA/GC/GF/GH
What is the difference is that the “INITIAL SETTINGS” data which is stored in Flash-ROM mounted on MAIN P.C.B..
3.4.1.
Defining methods:
To define the model suffix to be serviced, refer to the nameplate which is putted on the bottom side of the Unit.
NOTE:
After replacing the MAIN P.C.B., be sure to achieve adjustment.
The service software is available at “TSN Website”. To download, click on “Support Information from NWBG/VDBG-AVC”.
The service software is available at “TSN Website”. To download, click on “Support Information from NWBG/VDBG-AVC”.
10
3.4.2.
INITIAL SETTINGS:
After replacing the MAIN P.C.B., be sure to perform the initial settings after achieving the adjustment by ordering the following pro-
cedure in accordance with model suffix of the unit.
1. IMPORTANT NOTICE:
cedure in accordance with model suffix of the unit.
1. IMPORTANT NOTICE:
Before proceeding Initial settings, be sure to read the following CAUTIONS.
2. PROCEDURES:
• Precautions: Read the above "CAUTION 1" and "CAUTION 2", carefully.
• Preparation:
• Preparation:
- Attach the Battery or AC Adaptor with a DC coupler to the unit.
(Since this unit has built-in memory, it can be performed without inserting SD memory card.)
1. Turn the Power on.
2. Press the [ MODE ] button, and select the [ NORMAL PICTURE ] mode by Cursor buttons, then press the
2. Press the [ MODE ] button, and select the [ NORMAL PICTURE ] mode by Cursor buttons, then press the
[ MENU/SET ] button.
3. Turn the Power off.
(If the unit is other than [ NORMAL PICTURE ] mode, it does not display the initial settings menu.)
• Step 1. The temporary cancellation of “INITIAL SETTINGS”:
Set the [ REC ]/[ PLAYBACK ] selector switch to “[ REC ] (Camera mark)”.
While pressing “[ UP ] of Cursor button” and [ E.ZOOM ] button simultaneously, turn the Power on.
While pressing “[ UP ] of Cursor button” and [ E.ZOOM ] button simultaneously, turn the Power on.
• Step 2. The cancellation of “INITIAL SETTINGS”:
Set the [ REC ]/[ PLAYBACK ] selector switch to “[ PLAYBACK ]”.
Press “[ UP ] of Cursor button” and [ E.ZOOM ] button simultaneously, then turn the Power off.
Press “[ UP ] of Cursor button” and [ E.ZOOM ] button simultaneously, then turn the Power off.
The LCD displays the “ ! ” mark before the unit powers down.
• Step 3. Turn the Power on:
Set the [ REC ]/[ PLAYBACK ] selector switch to “[ REC ] (Camera mark)”, and then turn the Power on.
• Step 4. Display the INITIAL SETTING:
While pressing [ MENU/SET ] and “[ RIGHT ] of Cursor buttons” simultaneously, turn the Power off.
The "INITIAL SETTINGS" menu is displayed.
There are two kinds of “INITIAL SETTINGS” menu form as follows:
The "INITIAL SETTINGS" menu is displayed.
There are two kinds of “INITIAL SETTINGS” menu form as follows:
11
[CASE 1. After replacing MAIN P.C.B.]
When MAIN P.C.B. has just been replaced, all of the model suffix is displayed as follows. (Five pages in total)
When MAIN P.C.B. has just been replaced, all of the model suffix is displayed as follows. (Five pages in total)
[CASE 2. Other than “After replacing MAIN P.C.B.”]
• Step 5. Choose the model suffix in “INITIAL SETTINGS”: (Refer to “CAUTION 1”)
[Caution: After replacing MAIN P.C.B.]
The model suffix can been chosen, JUST ONE TIME.
Once one of the model suffix have been chosen, the model suffix lists will not be displayed, thus, it can not be changed.
Therefore, select the area carefully.
Once one of the model suffix have been chosen, the model suffix lists will not be displayed, thus, it can not be changed.
Therefore, select the area carefully.
Select the area with pressing “[ UP ] / [ DOWN ] of Cursor buttons”.
12
• Step 6. Chose the model number in “INITIAL SETTINGS”: (Only for “P” models.)
This step is necessary only for “P”.
Only for model suffix with “P”, there are two kind of model; (DMC-FH25 and DMC-FH24) ,due to difference of sales chan-
nel.Therefore, not only model suffix, but also model number (FH25 or FH24) has to be set up in the “INITIAL SETTINGS”. (The
“FH25” is displayed as default status.)
Only for model suffix with “P”, there are two kind of model; (DMC-FH25 and DMC-FH24) ,due to difference of sales chan-
nel.Therefore, not only model suffix, but also model number (FH25 or FH24) has to be set up in the “INITIAL SETTINGS”. (The
“FH25” is displayed as default status.)
When the model number is one of the "DMC-FH24P", change the model number with the following procedure:
Press the [E.ZOOM] button in order to change the indication from "FH25" into "FH24".
(Each time one presses the [E.ZOOM] button, model indication is changed from "FH25" to "FH24" (Toggle switch))
Press the [E.ZOOM] button in order to change the indication from "FH25" into "FH24".
(Each time one presses the [E.ZOOM] button, model indication is changed from "FH25" to "FH24" (Toggle switch))
• Step 7. Set the model suffix in “INITIAL SETTINGS”:
• Press the “[ RIGHT ] of Cursor buttons”.
• The only set area is displayed, and then press the “[ RIGHT ] of Cursor buttons” after confirmation.
• Press the “[ RIGHT ] of Cursor buttons”.
• The only set area is displayed, and then press the “[ RIGHT ] of Cursor buttons” after confirmation.
(The unit is powered off automatically.)
• Step 8. CONFIRMATION:
Confirm the display of “PLEASE SET THE CLOCK” in concernd language when the unit is turned on again.
When the unit is connected to PC with USB cable, it is detected as removable media.
(When the “GT” or “GK” model suffix is selected, the display shows “PLEASE SET THE CLOCK” in Chinese.)
When the unit is connected to PC with USB cable, it is detected as removable media.
(When the “GT” or “GK” model suffix is selected, the display shows “PLEASE SET THE CLOCK” in Chinese.)
1) As for your reference, major default setting condition is as shown in the following table.
• Default setting (After “INITIAL SETTINGS”)
MODEL
VIDEO OUTPUT
LANGUAGE
DATE
REMARKS
a) DMC-FH25P/FH24P
NTSC
English
Month/Date/Year
b) DMC-FS35EG
PAL
English
Date/Month/Year
c) DMC-FH25PU
NTSC
Spanish
Month/Date/Year
d) DMC-FH25GC
PAL
English
Date/Month/Year
e) DMC-FH25GT
NTSC
Chinese (traditional)
Year/Month/Date
f)
DMC-FH25GK
PAL
Chinese (simplified)
Year/Month/Date
g) DMC-FS35EF
PAL
French
Date/Month/Year
h) DMC-FS35EB
PAL
English
Date/Month/Year
i)
DMC-FS35EE
PAL
Russian
Date/Month/Year
j)
DMC-FH25GN
PAL
English
Date/Month/Year
k) DMC-FH25PC
NTSC
English
Month/Date/Year
l)
DMC-FH25PR
PAL
Spanish
Date/Month/Year
m) DMC-FH25GH
PAL
English
Date/Month/Year
n) DMC-FS35EP
PAL
English
Date/Month/Year
o) DMC-FH25GF
PAL
English
Date/Month/Year
p) DMC-FH25GA
PAL
English
Date/Month/Year
Click on the first or last page to see other DMC-FS35EB / DMC-FS35EE / DMC-FS35EF / DMC-FS35EG / DMC-FS35EP / DMC-FH25P / DMC-FH25PC / DMC-FH25PR / DMC-FH25PU / DMC-FH25GA / DMC-FH25GC / DMC-FH25GF / DMC-FH25GH / DMC-FH25GK / DMC-FH25GN / DMC-FH25GT / DMC-FH24P service manuals if exist.