Model
WV-CPR470 WV-CPR474E
Pages
20
Size
687.39 KB
Type
PDF
Document
Simplified Service Manual
Brand
Device
Video Monitoring / COLOUR CCTV CAMERA
File
wv-cpr470-wv-cpr474e.pdf
Date

Panasonic WV-CPR470 / WV-CPR474E Simplified Service Manual ▷ View online

ORDER NO. AVS0309507A8
Colour CCTV Cameras
WV-CPR470/WV-CPR474E
Please file and use this service manual together with original service manual for Model No. WV-CP470/
WV-CP474E, Order No. AVS0206442C1.
Simplified
WV
-
CPR470
SPECIFICATIONS
Pick-up device:
753 (H) x 582 (V) pixels, interline transfer CCD
Scanning area:
4.8 (H) x 3.6 (V) mm (Equivalent to scanning area of 1/3 in. pick-up tube)
Scanning:
625 lines/50 fields/25 frames
Horizontal:
15.625 kHz
Vertical:
50 Hz
Synchronization:
Internal, Line-lock, External (VS/VBS) or Multiplexed Vertical Drive (VD2) selectable
Gen-lock input:
VS/VBS, Termination ON/OFF with switch
Video output:
1.0 V [P-P] PAL composite 75 
/BNC connector
Horizontal resolution:
480 lines (C/L), 570 lines (B/W)
Signal-to-noise ratio:
50 dB (at AGC Off, weight On)
Dynamic range:
48 dB (typ)
Minimum Illumination:
0.8 lx (0.08 footcandle) at F1.4 (C/L), 0.1 lx (0.01 footcandle) at F1.4 (B/W)
Gain control:
ON (DNR-H), ON (DNR-L) or OFF (SET UP MENU) selectable
White balance:
ATW1, ATW2 or AWC (SET UP MENU) selectable
Aperture:
Set variable (SET UP MENU)
Electronic light control:
Equivalent to continuous variable shutter speeds between 1/50 s and 1/10 000 s
Super Dynamic2:
ON or OFF (SET UP MENU) selectable
Electronic shutter speed:
1/50 (OFF), 1/120, 1/250, 1/500, 1/1 000,1/2 000, 1/4 000, 1/10 000 s selectable
Interface:
Day/night input:
Pulled-up to 5 V DC, OFF (Open) / ON (0 V 2 mA)
Alarm status output:
Collector-output, OFF (Open)/ ON (load capacity 16 V DC 100 mA max.)
RS485:
4-wire/2-wire selectable with switch, Termination ON/OFF with switch
Lens mount:
CS-mount
ALC lens:
DC or Video selectable
Ambient operating temperature:
–10 °C to +50 °C (14 °F to 122 °F)
Ambient operating humidity:
Less than 90 %
Power source and
WV-CPR470:
220 V to 240 V AC 50 Hz, 6.1 W
power consumption:
WV-CPR474E:
24 V AC 50 Hz, 5.8 W
12 V DC, 610 mA
(Lens: Option)
2 0 0 3
M a t s u s h i t a   E l e c t r i c   I n d u s t r i a l   C o . ,   L t d .
A l l   r i g h t s   r e s e r v e d .   U n a u t h o r i z e d   c o p y i n g   a n d
d i s t r i b u t i o n   i s   a   v i o l a t i o n   o f   l a w .
The  Product  with  PbF
STANDARD ACCESSORIES
Body cap .............................................................................1 pc.
Floppy disk  ....................................................................... 2 pcs.
Instructions for RS485 camera series  ................................ 1 pc.
Operating instructions......................................................... 1 pc.
The following parts are used during installation.
ALC lens connector (YWM1943A)  ......................................1 pc.
AC power cord (only for WV-CPR470) ................................1 pc.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, 
DO NOT REMOVE COVER (OR BACK). NO USER 
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
This symbol warns the user that uninsulated voltage within 
the unit may have sufficient magnitude to cause electric 
shock. Therefore, it is dangerous to make any kind of contact 
with any inside part of this unit.
This symbol alerts the user that important literature concerning 
the operation and maintenance of this has been included.
Therefore,  it  should  be  read  carefully  in  order  to avoid 
any problems.
T
here are special components used in this equipment which are important for safety. These parts are indicated 
by the ”
 
Y
 
” mark on the schematic diagram and the replacement parts list. It is essential that these critical 
parts should be replaced with manufacturer's specified parts to prevent X-radiation, shock, fire, or other hazards.
Do not modify the original design without permission of manufacture.
IMPORTANT SAFETY NOTICE
About  Lead  Free  Solder (PbF)
Distribution of PbF PCB:
PCBs (manufactured) using lead free solder (PbF) will have a stamp on the PCB.
Caution:
8
Lead free solder has a higher melting point than standard solder. Typically the melting points is 35 
°
C – 40 
°
C
(95 
°
F – 104 
°
F) higher. Please use a soldering iron with temperature control and adjust it to 360 
°
C – 370 
°
C
(680 
°
F – 698 
°
F). In case of using high temperature soldering iron, please be careful not to heat too long.
8
Lead free solder will tend to splash when heated too high (600 
°
C / 1112 
°
F).
8
Lead free solder (Sn - 3.0Ag – 0.5Cu) or equivalents are recommended on repairing our lead free soldered PCB.
Y
   WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the 
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to 
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any 
attempt to service or repair the product or products dealt with in this service information by anyone else could 
result in serious injury or death.
Dimensions (without lens):
70 mm (W) x 65 mm (H) x 118 mm (D)
2-5/8" (W) x 2-9/16" (H) x 4-5/8" (D)
Weights (without lens):
WV-CPR470:
0.48 kg (1.1 lbs.) (without power cord)
WV-CPR474E:
0.46 kg (1.0 lbs.)
Weights and dimensions indicated are approximate.
Specifications are subject to change without notice.
CONTENTS
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ..............................................................................1-1
ADJUSTMENT PROCEDURE .................................................................................................................................2-1
WIRING DIAGRAM ..................................................................................................................................................3-1
BLOCK DIAGRAM
I/F BOARD / TERMINAL BOARD / POWER BOARD ..........................................................................................3-2
SCHEMATIC DIAGRAM 
MAIN BOARD (4/4)...............................................................................................................................................4-1
I/F BOARD (1/2) ...................................................................................................................................................4-2
I/F BOARD (2/2) / TERMINAL BOARD ................................................................................................................4-3
CONDUCTOR VIEW
I/F BOARD (COMPONENT SIDE) / TERMINAL BOARD ....................................................................................5-1
I/F BOARD (PATTERN SIDE)  .............................................................................................................................5-2
EXPLODED VIEW
WV-CPR470 .........................................................................................................................................................6-1
WV-CPR474E .......................................................................................................................................................6-2
REPLACEMENT PARTS LIST ................................................................................................................................7-1
This service manual describes difference from the WV-CP470/WV-CP474E.
• As for the rest of information, please refer to the original service manual for WV-CP470/WV-CP474E according to the table
below.
Item
WV-CP470/WV-CP474E
ADJUSTMENT PROCEDURE
Refer to the page 2
LOCATION OF TEST POINTS AND ADJUSTING CONTROLS
Refer to the page 12
BLOCK BIAGRAM
SENSOR BOARD / MAIN BOARD (1/2)
Refer to the page 14
MAIN BOARD (2/2)
Refer to the page 15
PARTITION DIAGRAM FOR SCHEMATIC DIAGRAM OF MAIN BOARD
Refer to the page 20
SCHEMATIC DIAGRAM
SENSOR BOARD
Refer to the page 17
MAIN BOARD (1/4)
Refer to the page 21
MAIN BOARD (2/4)
Refer to the page 22
MAIN BOARD (3/4)
Refer to the page 23
POWER BOARD (WV-CP470)
Refer to the page 28
POWER BOARD (WV-CP474E)
Refer to the page 29
CONDUCTOR VIEW
SENSOR BOARD
Refer to the page 18
MAIN BOARD
Refer to the page 19
POWER BOARD (WV-CP470)
Refer to the page 28
POWER BOARD (WV-CP474E)
Refer to the page 29
REPLACEMENT PARTS LIST
SENSOR BOARD
Refer to the page 32
!0
Right Button (
)
Moves the cursor to the right, selects the mode and adjusts
some levels.
!1
Down Button (
)
Moves the cursor downward and selects items in the CAM
SET UP menu.
!2
Gen-lock Input Connector (GEN-LOCK)
Connects an external system for synchronization.
!3
Video Output Connector (VIDEO OUT)
Connects the VIDEO IN connector of the monitor.
!4
Power Indicator (POWER)
!5
Input/output Terminal (IN/OUTPUT TERMINAL)
The 5-pole terminal connects RS485 communication lines. 
!6
Input/output Terminal (IN/OUTPUT TERMINAL)
The 4-pole terminal receives day/night signals and outputs
the alarm status. 
!7
AC Inlet Socket
Plug the power cord (supplied as a standard accessory)
into this socket and connect it to an AC outlet.
!8
AC/DC Compatible Input Terminal
(DC 12 V IN/AC 24 V IN)
This terminal is for connecting the 12 V DC or 24 V AC
power supply cord.
q
Auto Iris Lens Connector
Connects the auto iris lens with a 4-pin male connector sup-
plied as a standard accessory (Part No. YWM1943A).
w
Flange-back Adjusting Ring
Adjusts the back focal length and picture focus.
e
Flange-back Fixing Screw
r
Lens (Option)
t
Camera Mounting Screw Hole
Mounts the camera onto a mounting bracket.
y
DIP Switch
The 5-bit switch specifies the following. 
SW1:
Gen-lock line termination ON (75 
)/OFF (Open)
SW2:
RS485 line termination ON (150 
)/OFF (Open)
SW3-5:
RS485 2-line (Half-duplex)/4-line (Full-duplex)
selection
u
Left Button (       )
Moves the cursor to the left, selects the mode and adjusts
some levels.
i
Up Button (
)
Moves the cursor upward and selects items in the CAM SET
UP menu.
o
Set Button (
)
Activates an item selected in the CAM SET UP menu.
1-1
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
IN/OUTPUT
TERMINAL
220-240V ~ 50Hz
5
6
7
8
9
POWER
POWER
VIDEO OUT
GEN-LOCK
VIDEO OUT
GEN-LOCK
!1
!0
i o
u
y
4-LINE-2-LINE
Hi-Z-G/L 75
Hi-Z-
RS485
LINE TERM
q
e
!7
!3
!2
!3
!2
w
r
t
GND
1-L
2-N
AC 24V IN
DC 12V IN
!4
!4
!8
!5
!6
!5
!6
WV –
CPR470
WV-CPR470
WV-CPR474E
1
2
3
4
IN/OUTPUT
TERMINAL
5
6
7
8
9
1
2
3
4
Slide the panel to the left until it locks.
Page of 20
Display

Panasonic WV-CPR470 / WV-CPR474E Simplified Service Manual ▷ Download

  • DOWNLOAD Panasonic WV-CPR470 / WV-CPR474E Service Manual ↓ Size: 687.39 KB | Pages: 20 in PDF or view online for FREE
  • Here you can View online or download the Simplified Service Manual for the Panasonic WV-CPR470 / WV-CPR474E in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic WV-CPR470 / WV-CPR474E Video Monitoring. Information contained in Panasonic WV-CPR470 / WV-CPR474E Simplified Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.