Panasonic WV-CP480 / WV-CP484E Service Manual ▷ View online
ORDER NO. AVS0505624C8
Colour CCTV Camera
WV-CP480, WV-CP484E
SPECIFICATIONS
M a t s u s h i t a E l e c t r i c I n d u s t r i a l C o . , L t d .
A l l r i g h t s r e s e r v e d . U n a u t h o r i z e d c o p y i n g a n d
d i s t r i b u t i o n i s a v i o l a t i o n o f l a w .
d i s t r i b u t i o n i s a v i o l a t i o n o f l a w .
2 0 0 5
The Product with PbF
Pick-up device:
752 (H) x 582 (V) pixels, interline transfer CCD
Scanning area:
4.8 (H) x 3.6 (V) mm (Equivalent to scanning area of 1/3" pick-up tube)
Scanning:
625 lines/50 fields/25 frames
Horizontal:
15.625 kHz
Vertical:
50 Hz
Synchronization:
Multiplexed vertical drive (VD2), Line-locked, VBS/VS, or Internal
GEN LOCK input
VBS/VS 1.0 V[P-P] composite 75
Ω
/BNC connector
Video output:
1.0 V[P-P] PAL composite 75
Ω
/BNC connector
Resolution:
Horizontal 480 lines (C/L Normal), 540 lines typ., 520 lines min. (C/L High), 570 lines (B/W)
Vertical 400 lines (at centre)
Vertical 400 lines (at centre)
Signal-to-noise ratio:
50 dB (Equivalent to AGC Off, weight On)
Dynamic range:
54 dB typ
Minimum illumination:
0.6 lx {0.06 footcandle} at F1.4 (C/L),
0.5 lx {0.05 footcandle} at F1.2 (C/L),
0.08 lx {0.008 footcandle} at F1.4 (B/W),
0.06 lx {0.006 footcandle} at F1.2 (B/W)
0.5 lx {0.05 footcandle} at F1.2 (C/L),
0.08 lx {0.008 footcandle} at F1.4 (B/W),
0.06 lx {0.006 footcandle} at F1.2 (B/W)
Lens mount:
CS-mount
WV-CP480 (Lens: Option)
WV-CP484E (Lens: Option)
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK). NO USER
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK). NO USER
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
This symbol warns the user that uninsulated voltage within
the unit may have sufficient magnitude to cause electric
shock. Therefore, it is dangerous to make any kind of contact
with any inside part of this unit.
the unit may have sufficient magnitude to cause electric
shock. Therefore, it is dangerous to make any kind of contact
with any inside part of this unit.
This symbol alerts the user that important literature concerning
the operation and maintenance of this has been included.
Therefore, it should be read carefully in order to avoid
any problems.
the operation and maintenance of this has been included.
Therefore, it should be read carefully in order to avoid
any problems.
T
here are special components used in this equipment which are important for safety. These parts are indicated
by the ”
Y
” mark on the schematic diagram and the replacement parts list. It is essential that these critical
parts should be replaced with manufacturer's specified parts to prevent X-radiation, shock, fire, or other hazards.
Do not modify the original design without permission of manufacture.
IMPORTANT SAFETY NOTICE
About Lead Free Solder (PbF)
Distribution of PbF PCB:
PCBs (manufactured) using lead free solder (PbF) will have a stamp on the PCB.
Caution:
8
Lead free solder has a higher melting point than standard solder. Typically the melting points is 35
°
C – 40
°
C
(95
°
F – 104
°
F) higher. Please use a soldering iron with temperature control and adjust it to 360
°
C – 370
°
C
(680
°
F – 698
°
F). In case of using high temperature soldering iron, please be careful not to heat too long.
8
Lead free solder will tend to splash when heated too high (600
°
C / 1112
°
F).
8
Lead free solder (Sn - 3.0Ag – 0.5Cu) or equivalents are recommended on repairing our lead free soldered PCB.
Y
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any
attempt to service or repair the product or products dealt with in this service information by anyone else could
result in serious injury or death.
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any
attempt to service or repair the product or products dealt with in this service information by anyone else could
result in serious injury or death.
Major items on menu setup
Language:
English, French, German, Spanish, Italian, Japanese, Russian, or Chinese
Camera ID:
Up to 16 characters
Light control
ALC/ELC
Super Dynamic 3:
ON or OFF
Electronic shutter speed:
1/50 (OFF), 1/120, 1/250, 1/500, 1/1 000,1/2 000, 1/4 000, 1/10 000 s
Gain control:
ON (HIGH), ON (MID), ON (LOW), or OFF
Sensitivity enhancement:
OFF, x2AUTO, x4AUTO, x6AUTO, x10AUTO, x2FIX, x4FIX, x6FIX, x10FIX, x16FIX, x32FIX
White balance:
ATW1, ATW2, or AWC
Motion detection:
MODE1, MODE2, or OFF
Digital noise reduction:
HIGH or LOW
Resolution:
NORMAL or HIGH
Black-and-white mode:
AUTO1, AUTO2, EXT, ON, or OFF
Privacy zone:
ON(1), ON(2), or OFF
Mirror:
ON or OFF
ALC lens drive:
DC or VIDEO
Auto image stabilizer
ON or OFF
Back focus adjustment:
ABF, MANUAL, AUTO/PRESET/FIX
Special:
CHROMA, APERTURE, PEDESTAL adjustable
Ambient Operating Temperature:
–10 °C - +50 °C
Ambient Operating Humidity:
Less than 90 %
Power Source and
Power Consumption:
WV-CP480: 220 V - 240 V AC 50 Hz, 4.6 W
WV-CP484E: 24 V AC 50 Hz, 4.7 W
WV-CP484E: 12 V DC, 420 mA
WV-CP484E: 24 V AC 50 Hz, 4.7 W
WV-CP484E: 12 V DC, 420 mA
Dimensions (without lens):
WV-CP480: 70 mm (W) x 65 mm (H) x 129 mm (D)
WV-CP484E: 67 mm (W) x 65 mm (H) x 100 mm (D)
WV-CP484E: 67 mm (W) x 65 mm (H) x 100 mm (D)
Weights (without lens):
WV-CP480: 520
g (Without power cord)
WV-CP484E: 400
g
Weights and dimensions indicated are approximate.
Specifications are subject to change without notice.
Specifications are subject to change without notice.
STANDARD ACCESSORIES
Operating Instructions ............................................1 pc.
ALC Lens Connector (YWM1943A) ........................1 pc.
AC Power Cord (for WV-CP480) .............................1 pc.
ALC Lens Connector (YWM1943A) ........................1 pc.
AC Power Cord (for WV-CP480) .............................1 pc.
OPTIONAL ACCESSORIES
Lenses :
WV-LA2R8C3B, WV-LA4R5C3B, WV-LA9C3B, WV-LZ61/15, WV-LZA61/2S, WV-LZ62/8S, WV-LF4R5C3A,
WV-LF9C3A, WV-LZF61/2
WV-LF9C3A, WV-LZF61/2
C-mount Adapter : WV-AD20E
CONTENTS
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS .........................................................1-1
ADJUSTMENT PROCEDURE.............................................................................................................2-1
WIRING DIAGRAM
WV-CP480 .......................................................................................................................................3-1
WV-CP484E .....................................................................................................................................3-2
SCHEMATIC DIAGRAM
SENSOR BOARD ............................................................................................................................4-1
MAIN BOARD (1/2) / ABF LIMITER BOARD ...................................................................................4-2
MAIN BOARD (2/2) ..........................................................................................................................4-3
I/F BOARD FOR WV-CP480 ............................................................................................................4-4
I/F BOARD FOR WV-CP484E .........................................................................................................4-5
POWER BOARD FOR WV-CP480 ..................................................................................................4-6
POWER BOARD FOR WV-CP484E ................................................................................................4-7
CONDUCTOR VIEW
SENSOR BOARD / ABF LIMITER BOARD .....................................................................................5-1
MAIN BOARD...................................................................................................................................5-2
I/F BOARD FOR WV-CP480 ............................................................................................................5-3
I/F BOARD FOR WV-CP484E .........................................................................................................5-4
POWER BOARD FOR WV-CP480 ..................................................................................................5-5
POWER BOARD FOR WV-CP484E ................................................................................................5-6
EXPLODED VIEW
(1/6) ..................................................................................................................................................6-1
(2/6) ..................................................................................................................................................6-2
(3/6) ..................................................................................................................................................6-3
(4/6) ..................................................................................................................................................6-4
(5/6) ..................................................................................................................................................6-5
(6/6) ..................................................................................................................................................6-6
REPLACEMENT PARTS LIST ............................................................................................................7-1