– 4 –
5. Adjustment Procedure
8
Refer to the Location of Test Points and Adjusting Con-
trols on the page 6.
(1) +10V Confirmation
Test Point:
Pin 5 of CN1 (+10V)
Video Board
8
Connect the Digital Voltmeter to Pin 5 of CN1.
8
Confirm that the Voltage at pin 5 of CN1 should be within
10.0 V ± 0.5 V.
(2) +5V Confirmation
Test Point:
+Polarity of C9 (+5V)
Video Board
8
Connect the Digital Voltmeter to + polarity of C9.
8
Confirm that the Voltage at + polarity of C9 should be
within 5.0 V ± 0.5 V.
(3) V
SUB
Adjustment
Test Point:
TP4 (IRIS SIG)
Video Board
Adjust:
VR1 (V
SUB
)
Video Board
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the Oscilloscope to TP4.
8
Set the Lens Iris so that the signal level at TP4 becomes
approximately 1 750 mV as shown in Fig.5-1.
1 750 mV
1 500 mV 
±
100 mV
(4) Pedestal and Video Output Adjustment
Test Point:
CN4 (Video Output Connector)Video Board
Adjusts:
VR3 (PEDESTAL)
Video Board
VR4 (VIDEO OUTPUT)
Video Board
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the Oscilloscope terminated with 75
to CN4.
8
Cap on the Lens.
8
Adjust VR3 so that the Pedestal signal level becomes
50 mV ± 10 mV as shown in Fig.5-3.
50 mV 
±
 10 mV
Fig. 5-3
8
Remove the Cap from the Lens.
8
Adjust VR4 so that the Video signal level becomes
700 mV ± 30 mV as shown in Fig. 5-4.
(5) ELC Level Adjustment
Test Point:
TP4 (IRIS SIG)
Video Board
Adjust:
VR5 (ELC LEVEL)
Video Board
8
Set the Automatic Light Control/Electronic Light Control
Selector (on the Video Board SW1) to ELC position.
8
Aim the Camera at the Logarithmic Gray Scale Chart .
8
Connect the Oscilloscope to TP4.
8
While closing slowly the Lens Iris from Iris open (F1.4),
adjust VR5 so that the signal level at TP4 changes
between Ground level and 500 mV DC alternately.
700 mV 
±
 30 mV
Fig. 5-4
8
Confirm that the ELC Function activates smoothly when
putting on and taking off the Lens Cap.
Fig. 5-2
8
Set the Lens Iris to standard specified level.
Fig. 5-1
8
Adjust VR1 so that the maximum luminance section (11th
portion of the Gray Scale Chart) of the signal at TP4  sat-
urates at 1 500 mV ± 100 mV as shown in Fig.5-2.
If can not reach to the specified level, while changing
(opening) the Lens Iris, adjust VR1 to the point where
only the 11th portion saturates.
– 5 –
8
Adjust VR2 so that the Video signal level becomes
700 mV ± 30 mV as shown in Fig. 5-5.
(6) ALC Level Adjustment
Test Point:
CN4 (Video Output Connector)Video Board
Adjust:
VR2 (ALC LEVEL)
Video Board
8
Mount the ALC Lens (WV-LA9C3) on the Camera.
8
Set the Automatic Light Control/Electronic Light Control
Selector (on the Video Board SW1) to ALC position.
8
Aim the Camera at the Logarithmic Gray Scale Chart .
8
Connect the Oscilloscope to CN4.
Fig. 5-5
700 mV 
±
 30 mV
8
Confirm that the ALC Function activates smoothly when
putting on and taking off the Lens Cap.
Fig. 5-6
(7) Flange-back Adjustment
Test Point:
CN4 (Video Output Connector)Video Board
Adjust:
Flange-back Adjusting Ring
8
Set the Radiation Chart.
8
Incident light of 500 lx on the Radiation Chart.
8
Aim the Camera at the Radiation Chart distance of 10m.
8
Mount ND8 Filter(1 pc.) and ND2 Filter(1 pc.) on the
Lens.
8
Referring to Fig. 5-6, loosen the Focus Fixing screw
(LOCK) that secure the Flange-back Adjusting Ring.
Flange-back
Adjusting Ring
Focus Fixing 
Screw (LOCK)
LOCK
8
Adjust the Flange-back Adjusting Ring to obtain best focal
point.
8
Tighten the Focus fixing screw (LOCK) that secure the
Flange-back Adjusting Ring carefully.
– 6 –
LOCATION OF TEST POINTS AND ADJUSTING CONTROLS
CN1
Pin5 of CN1
(+10V)
+Polarity of C9
(+5V)
VR5
(ELC LEVEL)
VR3
(PEDESTAL)
VR4
(VIDEO OUTPUT)
VR1
( V
SUB
)
TP4
(IRIS SIG)
VR2
(ALC LEVEL)
SW1
Lens Drive Signal
Selector
Automatic Light Control/
Electronic Light Control
Selector
Back Light Compensation
Mode Selector
VIDEO/DC
ALC/ELC
(ELC)
(ALC)
BLC ON/OFF
CN4
(Pattern
      Side)
Main
Chassis
CN3
CN1
CN2
Front
Escutcheon
Auto Iris Lens
Connector
Video Output
Connector
[VIDEO OUT]
To
Power Board
4
3
2
1
6
5
Sensor Board
<Bottom View>
Video Board (Component Side)
Note: IC1 is not included in Sensor Board Ass'y.
CCD IMAGE SENSOR
VERTICAL DRIVER
TIMING GENERATOR
SIGNAL PROCESSOR
CCD
OUTPUT
ALC/ELC
COMPARATOR
IRIS
OUTPUT
VCO
VCXO
WV-BP140/WV-BP144E
ONLY
WV-BP142E ONLY
TO
VIDEO BOARD
CN3
(Page 8)
+15V
IC1
(IC2)
IC4
Q1
IC3
IC8
-9V
+15V
+5V
+5V
1
2
3
16
11
13
19
12
21
15
14
30
26
27
25
7
9
5
CN1
+15V
-9V
SUB-BIAS
SUB-BIAS
ALC(HD)
LL-PULSE
VD
PCO
VP-DET
Y
A/B CONT
ALC/ELC
ELC(VR)
PED(VR)
IRIS
CSYNC
AGC(VR)
FL
Y
A/B CONT
ALC/ELC
ELC(VR)
PED(VR)
IRIS
CSYNC
AGC(VR)
FL
+5V
+15V
-9V
+5V
-9V
9
8
VDD
V-OUT
VGG
VL
VHH
OV1
OV2
OV3
OV4
XV1
V1
XV2
XV3
XV4
XSG1
XSG3
XSUB
DCIN
VSUB
DCOUT
VCP
VEE
*
V1
*
V2
*
V3
*
V4
*
RS
*
H1
*
H2
XPG
H1
H2
+5V
SUB
6
12
9
20 12
18
4
3
2
1
11
13
15
16
16
17
14
13
19
MAX-CTL
GAMMA-CT
PG-IN
DATA-IN
KNEE-SW
DELAY-CT
APER-CTL
9
15
1
2
SHD
SHP
FL
Y
CSYNC
45
46
COM1(O) 36
COM2(O) 35
OP-CLP
33
DM-CLP
47
BLANK 30
1
2
4
WND-BLK 41
SYNC(I)
29
VIDEO(O)
32
SAG(I) 31
Q4,R32-35
Q2,3
COM1(I) 37
COM2(I) 39
COM12(I)
38
SETUP(C)
GAIN-CTL
26
10
OP(O)
11
OP(I) 12
IRIS(O) 40
16
20
21
CLIP-CTL
VCA(C)
WC-CTL
22
23
27
G-CLP
7
LPF-R
A-CLP
IRIS-CLP
14
19
42
VREF
43
AGC(O)
4
GAMMA(I)
5
DET(O)
8
OP(I)+
13
AP(O)
VIDEO(I)
24
25
4
3
V2
6
8
5
7
2
28
29
26
24
27
25
30
20
43
19
42
V3
V4
XSG1
XSG2
XSUB
35
36
37
V1
V2
V3
V4
XSG1
HD
VRN
VD
CLK1
46
39
EXT1
IC7,X1
IC6,L4,D3,4
X1
45
48
RSTN
MD1
XSG2
XSUB
XPG
H1
H2
34
33
6
SHD
SHP
SM0
SHD
SHP
SM0
7
SM1
SM1
21
CLP1
CLP2
CBLK
WND
22
17
15
CLP2
CBLK
WND
CSYNC
16 CSYNC
ALC/ELC
ALC/ELC
ELC(VR)
A/B CONT
IRIS
PED(VR)
AGC(VR)
IC5
9
4
2
EES
CLP1
SUB-BIAS
10
11
SENSOR BOARD
– 7 –
BLOCK DIAGRAM OF SENSOR BOARD
BLOCK DIAGRAM OF SENSOR BOARD
Page of 29
Display

Click on the first or last page to see other WV-BP140 service manuals if exist.