Panasonic WJ-HD200 Service Manual ▷ View online
SPECIFICATIONS
General
Power Source Required :
120 V AC, 60 Hz for NTSC
220 V – 240 VAC, 50 Hz for PAL
220 V – 240 VAC, 50 Hz for PAL
Power Consumption :
45 W
Ambient Operating Temperature :
+5 °C – +45 °C (41 °F – 113 °F)
Ambient Operating Humidity :
Less than 85 %
Dimensions :
420 mm (W) x 44 mm (H) x 350 mm (D) [16-9/16” (W) x 3-7/16” (H) x 13-3/4” (D)]
Weight :
5.2 k
g
(11.4 lbs.)
Input
Video Input :
1.0 V[p-p]/75
Ω
Composite video signal with 75
Ω
Automatic Termination / Looping
through (x8)
Audio Input :
–10 dB 10 k
Ω
unbalanced, RCA standard jack
Image Process
Compression System :
JPEG
Pixel Rate :
672 x 224 for NTSC, 656 x 272 for PAL
Refresh Rate :
30 FPS maximum for NTSC, 25 FPS maximum for PAL
Output
Video Output :
1.0 V[p-p]/75
Ω
Composite video signal/Looping through (x8)
Video Output Front Panel :
1.0 V[p-p]/75
Ω
Composite video signal (x1)
Audio Output :
–10 dB 600
Ω
unbalanced, RCA standard jack (x1)
WJ-HD200
ORDER NO. AVS0304492C0
S16
S16
4
8
3
7
2
6
1
5
OPERATE
ALARM
SUSPEND
RESET
HDD
FULL
ERROR
OSD
DST
MULTISCREEN
SELECT
ZOOM
TIMER
REMOTE
LOCK
SEQUECE
ALARM
SERCH
STOP
PLAY MODE SERECT
PLAY
TIME&D
ATE
SEARCH
REC STOP
SPOT
MULTI
CAMERA SELECT
ALARM
REC
REC
PUSH– P
AUSE
SET
Digital Disk Recorder
WJ-HD200
SETUP
/ESC
Digital Desk Recorder
2 0 0 3
M a t s u s h i t a E l e c t r i c I n d u s t r i a l C o . , L t d .
A l l r i g h t s r e s e r v e d . U n a u t h o r i z e d c o p y i n g a n d
d i s t r i b u t i o n i s a v i o l a t i o n o f l a w .
d i s t r i b u t i o n i s a v i o l a t i o n o f l a w .
The Product with PbF
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK). NO USER
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK). NO USER
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
This symbol warns the user that uninsulated voltage within
the unit may have sufficient magnitude to cause electric
shock. Therefore, it is dangerous to make any kind of contact
with any inside part of this unit.
the unit may have sufficient magnitude to cause electric
shock. Therefore, it is dangerous to make any kind of contact
with any inside part of this unit.
This symbol alerts the user that important literature concerning
the operation and maintenance of this has been included.
Therefore, it should be read carefully in order to avoid
any problems.
the operation and maintenance of this has been included.
Therefore, it should be read carefully in order to avoid
any problems.
T
here are special components used in this equipment which are important for safety. These parts are indicated
by the ”
Y
” mark on the schematic diagram and the replacement parts list. It is essential that these critical
parts should be replaced with manufacturer's specified parts to prevent X-radiation, shock, fire, or other hazards.
Do not modify the original design without permission of manufacture.
IMPORTANT SAFETY NOTICE
About Lead Free Solder (PbF)
Distribution of PbF PCB:
PCBs (manufactured) using lead free solder (PbF) will have a stamp on the PCB.
Caution:
8
Lead free solder has a higher melting point than standard solder. Typically the melting points is 35
°
C – 40
°
C
(95
°
F – 104
°
F) higher. Please use a soldering iron with temperature control and adjust it to 360
°
C – 370
°
C
(680
°
F – 698
°
F). In case of using high temperature soldering iron, please be careful not to heat too long.
8
Lead free solder will tend to splash when heated too high (600
°
F / 1112
°
F).
8
Lead free solder (Sn - 3.0Ag – 0.5Cu) or equivalents are recommended on repairing our lead free soldered PCB.
Y
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any
attempt to service or repair the product or products dealt with in this service information by anyone else could
result in serious injury or death.
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any
attempt to service or repair the product or products dealt with in this service information by anyone else could
result in serious injury or death.
Warning
The lithium battery in this equipment must only be
replaced by qualified personnel. When necessary,
contact your local Panasonic supplier.
replaced by qualified personnel. When necessary,
contact your local Panasonic supplier.
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended
by the equipment manufacturer. Discard used batteries
according to manufacturer's instructions.
Replace only with the same or equivalent type recommended
by the equipment manufacturer. Discard used batteries
according to manufacturer's instructions.
SAFETY PRECAUTIONS
GENERAL GUIDELINE
1. When service is required, observe the original lead dress.
Components, wires or cables that indicate evidence of
overheating or other electrical or mechanical damage
should be replaced.
2.
After servicing see to that all the protective devices, such
as insulation tape, shields must be properly installed.
3.
After servicing, make the following leakage current checks
to prevent the customer from being exposed to shock
hazards.
LEAKAGE CURRENT COLD CHECK
1.
Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2.
Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc.
When the exposed metallic part has a return path to the
chassis, the reading should be between 1 M
Ω
and
5.2 M
Ω
. When the exposed metal does not have a return
path to the chassis, the reading must be
∞
(infinity).
Any resistance value below this range indicates an
abnormality which requires corrective action.
3.
Repeat the test with the AC switch in the "OFF" position.
LEAKAGE CURRENT HOT CHECK
1.
Plug the AC cord directly into adaptor socket and plug
adaptor into the AC outlet. Do not use an isolation
transformer for this check.
2.
Connect a 1.5 k
Ω
/ 10 W resistor, paralleled by 0.15
µ
F
capacitor, between each exposed metallic part on the unit
and a good earth ground such as a water pipe, as shown
in Figure 1.
3.
Use an AC Voltmeter, with 1 k
Ω
/ Volt or more sensitivity,
to measure the potential across the resistor.
4.
Check all exposed metallic parts of the cover (BNC
connector, Handle bracket, Metallic cabinet, Screwheads,
Metallic overlays, etc.), and measure the voltage at each
point.
5.
Reverse the AC plug in the AC plug adaptor and repeat
each of the above measurements.
6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (SIMPSON MODEL 229 or
equivalent) may be used to make the hot checks.
Leakage current must not exceed 0.5 milliampere.
In case a measurement is outside of the limits specified,
there is a possibility of a shock hazard, and corrective
action must be taken before returning the instrument to
the customer.
AC VOLTMETER
1.5 k
Ω
0.15
µ
F
Water Pipe
(Earth Ground)
Test all exposed
metal parts
metal parts
DEVICE
UNDER
TEST
UNDER
TEST
AC PLUG
ADAPTOR
AC OUTLET
Ground Lead Disconnected during safety check.
Fig. 1 Leakage Current Hot Check
PRODUCT COMPLIES WITH DHHS RULES 21 CFR SUBCHAPTER J
APPLICABLE AT DATE OF MANUFACTURE
APPLICABLE AT DATE OF MANUFACTURE
FOR WJ-HD200 (NTSC)
Audio Output Front Panel :
–10 dB 600
Ω
unbalanced, RCA standard jack (x1)
Spot Monitor Output :
1.0 V[p-p]/75
Ω
Composite video signal (x1)
Multi-screen Monitor Output :
1.0 V[p-p]/75
Ω
Composite video signal (x1)
Control Port
Alarm/Remote Port :
25-pin Full Pitch D-sub connector (x1)
Alarm Input 1-8, Alarm Reset Input, EXT REC Input, Time Adjust Input, Sequence
Input: Low-active, Non-voltage N.O. Contact,
Alarm Input 1-8, Alarm Reset Input, EXT REC Input, Time Adjust Input, Sequence
Input: Low-active, Non-voltage N.O. Contact,
≥
100 ms
Alarm Output 1, Alarm Recovery Output 1, Disk End Status Output, Time Adjust Output,
Warning Output, REC Status Output, Play Status Output,
Sequence Output: Low-active, Open-collector, 24 VDC 100 mA max.
Alarm Output 2: High-active, 12 V 4.7 k
Warning Output, REC Status Output, Play Status Output,
Sequence Output: Low-active, Open-collector, 24 VDC 100 mA max.
Alarm Output 2: High-active, 12 V 4.7 k
Ω
Alarm Recovery Output 2: High-active, 12 VDC 220
Ω
RS-485 (PS
•
Data) :
6-conductor modular jack (RJ-11)
RS-232C :
9-pin Full Pitch D-sub connector
10/100BASE-TX Port :
10Base-T and 100Base-TX, 8-conductor modular jack (RJ-45)
Protocol Installed: TCP/IP, HTTP, FTP, SMTP, SNMP, DNS, DDNS
Security: Password-protected
Protocol Installed: TCP/IP, HTTP, FTP, SMTP, SNMP, DNS, DDNS
Security: Password-protected
Hard Disk Drive
Built-in :
120 GB (x1)
Extension :
Optional 1 unit, available using built-in bracket
Weight and dimensions shown are approximate.
Specifications are subject to change without notice.
Specifications are subject to change without notice.
STANDARD ACCESSORIES
Rack Mounting Bracket ............................................................... 2 pcs.
Screw for Rack Mounting Bracket (M3x10) ................................. 6 pcs.
Absorber ...................................................................................... 4 pcs.
Sleeve .......................................................................................... 4 pcs.
Hard Disk Fixing Screw ............................................................... 4 pcs.
Earth Lug ..................................................................................... 1 pc. for PAL
Screw for Rack Mounting Bracket (M3x10) ................................. 6 pcs.
Absorber ...................................................................................... 4 pcs.
Sleeve .......................................................................................... 4 pcs.
Hard Disk Fixing Screw ............................................................... 4 pcs.
Earth Lug ..................................................................................... 1 pc. for PAL