DOWNLOAD Panasonic WJ-HD200 Service Manual ↓ Size: 2.82 MB | Pages: 43 in PDF or view online for FREE

Model
WJ-HD200
Pages
43
Size
2.82 MB
Type
PDF
Document
Service Manual
Brand
Device
Video Monitoring / DIGITAL DESK RECORDER
File
wj-hd200.pdf
Date

Panasonic WJ-HD200 Service Manual ▷ View online

SPECIFICATIONS
General
Power Source Required :
120 V AC, 60 Hz for NTSC
220 V – 240 VAC, 50 Hz for PAL
Power Consumption :
45 W
Ambient Operating Temperature :
+5 °C – +45 °C (41 °F – 113 °F)
Ambient Operating Humidity :
Less than 85 %
Dimensions :
420 mm (W) x 44 mm (H) x 350 mm (D) [16-9/16” (W) x 3-7/16” (H) x 13-3/4” (D)]
Weight :
5.2 k
g
(11.4 lbs.)
Input
Video Input :
1.0 V[p-p]/75 
Composite video signal with 75 
Automatic Termination / Looping
through (x8)
Audio Input :
–10 dB 10 k
unbalanced, RCA standard jack
Image Process
Compression System :
JPEG
Pixel Rate :
672 x 224 for NTSC, 656 x 272 for PAL
Refresh Rate :
30 FPS maximum for NTSC, 25 FPS maximum for PAL
Output
Video Output :
1.0 V[p-p]/75 
Composite video signal/Looping through (x8)
Video Output Front Panel :
1.0 V[p-p]/75 
Composite video signal (x1)
Audio Output :
–10 dB 600 
unbalanced, RCA standard jack (x1)
WJ-HD200
ORDER NO. AVS0304492C0
S16
4
8
3
7
2
6
1
5
OPERATE
ALARM
SUSPEND
RESET
HDD
FULL
ERROR
OSD
DST
MULTISCREEN
SELECT
ZOOM
TIMER
REMOTE
LOCK
SEQUECE
ALARM
SERCH
STOP
PLAY MODE SERECT
PLAY
TIME&D
ATE
SEARCH
REC STOP
SPOT
MULTI
CAMERA SELECT
ALARM
REC
REC
PUSH–    P
AUSE
SET
Digital Disk Recorder 
WJ-HD200
SETUP
/ESC
Digital  Desk  Recorder
2 0 0 3
M a t s u s h i t a   E l e c t r i c   I n d u s t r i a l   C o . ,   L t d .
A l l   r i g h t s   r e s e r v e d .   U n a u t h o r i z e d   c o p y i n g   a n d
d i s t r i b u t i o n   i s   a   v i o l a t i o n   o f   l a w .
The  Product  with  PbF
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO  REDUCE THE RISK OF ELECTRIC SHOCK, 
DO NOT REMOVE COVER (OR BACK). NO USER 
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
This symbol warns the user that uninsulated voltage within 
the unit may have sufficient magnitude to cause electric 
shock. Therefore, it is dangerous to make any kind of contact 
with any inside part of this unit.
This symbol alerts the user that important literature concerning 
the operation and maintenance of this has been included.
Therefore,  it  should  be  read  carefully  in  order  to avoid 
any problems.
T
here are special components used in this equipment which are important for safety. These parts are indicated 
by  the ”
 
Y
 
”  mark on the schematic diagram and the replacement parts list. It is essential that these critical 
parts should be replaced with manufacturer's specified parts to prevent X-radiation, shock, fire, or other hazards.
Do not modify the original design without permission of manufacture.
IMPORTANT SAFETY NOTICE
About  Lead  Free  Solder (PbF)
Distribution of PbF PCB:
PCBs (manufactured) using lead free solder (PbF) will have a stamp on the PCB.
Caution:
8
Lead free solder has a higher melting point than standard solder. Typically the melting points is 35 
°
C – 40 
°
C
(95 
°
F – 104 
°
F) higher. Please use a soldering iron with temperature control and adjust it to 360 
°
C – 370 
°
C
(680 
°
F – 698 
°
F). In case of using high temperature soldering iron, please be careful not to heat too long.
8
Lead free solder will tend to splash when heated too high (600 
°
F / 1112 
°
F).
8
Lead free solder (Sn - 3.0Ag – 0.5Cu) or equivalents are recommended on repairing our lead free soldered PCB.
Y
   WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the 
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to 
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any 
attempt to service or repair the product or products dealt with in this service information by anyone else could 
result in serious injury or death.
Warning
The lithium battery in this equipment must only be 
replaced by qualified personnel. When necessary, 
contact your local Panasonic supplier.
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended 
by  the equipment manufacturer. Discard used batteries 
according to manufacturer's instructions.
SAFETY PRECAUTIONS
GENERAL GUIDELINE
1. When service is required, observe the original lead dress.
   
Components, wires or cables that indicate evidence of
overheating or other electrical or mechanical damage
should be replaced.
2.
       
After servicing see to that all the protective devices, such
  as insulation tape, shields must be properly installed.
3. 
 
After servicing, make the following leakage current checks
to prevent the customer from being exposed to shock
  hazards.
LEAKAGE CURRENT COLD CHECK
1.
       
Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2.
       
Measure the resistance value, with an ohmmeter, between
     
the jumpered AC plug and each exposed metallic cabinet
 
             
part on the equipment such as screwheads, connectors,
         
control shafts, etc.
         
When the exposed metallic part has a return path to the
           
chassis, the reading should be between 1 M
  and 
           
5.2 M
. When the exposed metal does not have a return
path to the chassis, the reading must be 
  (infinity).
               
Any resistance value below  this range indicates an
abnormality which requires corrective action.
3.
       
Repeat the test with the AC switch in the "OFF" position.
LEAKAGE CURRENT HOT CHECK
1.
     
Plug the AC cord directly into adaptor socket and plug
 
           
adaptor into the AC outlet. Do not use an isolation
transformer for this check.
2.
         
Connect a 1.5 k
  / 10 W resistor, paralleled by 0.15 
µ
F
     
capacitor, between each exposed metallic part on the unit
    
and a good earth ground such as a water pipe, as shown
       
in Figure 1.
3.
     
Use an AC Voltmeter, with 1 k
 / Volt or more sensitivity,
to measure the potential across the resistor.
4.
     
Check all exposed metallic parts of the cover (BNC
    
connector, Handle bracket, Metallic cabinet, Screwheads,
Metallic overlays, etc.), and measure the voltage at each
       
point.
5.
       
Reverse the AC plug in the AC plug adaptor and repeat
        
each of the above measurements.
6. The potential at any point should not exceed 0.75 V RMS.
 
           
A leakage current tester (SIMPSON MODEL 229 or
 
        
equivalent) may be used to make the hot checks.
 
       
Leakage current must not exceed 0.5 milliampere.
       
In case a measurement is outside of the limits specified,
       
there is a possibility of a shock hazard, and corrective
         
action must be taken before returning the instrument to 
          
the customer.
AC  VOLTMETER
1.5 k
0.15 
µ
F
Water  Pipe
 (Earth  Ground)
Test  all  exposed
metal  parts
DEVICE
UNDER
TEST
AC  PLUG
ADAPTOR
AC  OUTLET
Ground  Lead    Disconnected during safety check.
Fig. 1   Leakage  Current  Hot  Check
PRODUCT COMPLIES WITH DHHS RULES 21 CFR SUBCHAPTER J 
APPLICABLE AT DATE OF MANUFACTURE
FOR WJ-HD200 (NTSC)
Audio Output Front Panel :
–10 dB 600 
unbalanced, RCA standard jack (x1)
Spot Monitor Output :
1.0 V[p-p]/75 
Composite video signal (x1)
Multi-screen Monitor Output :
1.0 V[p-p]/75 
Composite video signal (x1)
Control Port
Alarm/Remote Port :
25-pin Full Pitch D-sub connector (x1)
Alarm Input 1-8, Alarm Reset Input, EXT REC Input, Time Adjust Input, Sequence
Input: Low-active, Non-voltage N.O. Contact, 
100 ms
Alarm Output 1, Alarm Recovery Output 1, Disk End Status Output, Time Adjust Output,
Warning Output, REC Status Output, Play Status Output, 
Sequence Output: Low-active, Open-collector, 24 VDC 100 mA max.
Alarm Output 2: High-active, 12 V 4.7 k
Alarm Recovery Output 2: High-active, 12 VDC 220 
RS-485 (PS
Data) :
6-conductor modular jack (RJ-11)
RS-232C :
9-pin Full Pitch D-sub connector
10/100BASE-TX Port :
10Base-T and 100Base-TX, 8-conductor modular jack (RJ-45)
Protocol Installed: TCP/IP, HTTP, FTP, SMTP, SNMP, DNS, DDNS
Security: Password-protected
Hard Disk Drive
Built-in :
120 GB (x1)
Extension :
Optional 1 unit, available using built-in bracket
Weight and dimensions shown are approximate.
Specifications are subject to change without notice.
STANDARD ACCESSORIES
Rack Mounting Bracket  ............................................................... 2 pcs.
Screw for Rack Mounting Bracket (M3x10)  ................................. 6 pcs.
Absorber ...................................................................................... 4 pcs.
Sleeve .......................................................................................... 4 pcs.
Hard Disk Fixing Screw  ............................................................... 4 pcs.
Earth Lug  ..................................................................................... 1 pc. for PAL
Page of 43
Display

Panasonic WJ-HD200 Service Manual ▷ Download

  • DOWNLOAD Panasonic WJ-HD200 Service Manual ↓ Size: 2.82 MB | Pages: 43 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic WJ-HD200 in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic WJ-HD200 Video Monitoring. Information contained in Panasonic WJ-HD200 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.