5.1.3. Wiring schematic diagram
Note:
    
·
    
The Door Opener wiring schematic diagram is an example. To connect to a Door Opener, make sure the Door Opener is:
     − 
− 
− 
− 
Normal open (Low active)
     − 
− 
− 
− 
Below AC30 V (1 A), DC24 V (1 A)
    
·
    
Please see the PBX/Door Opener manuals for further details.
5.1.4. Power cable/wire type and distance
    
·
    
Power cable (between the monitor station and the AC adaptor):
Type:
1.2 Fire alarm cable 16 AWG
Distance: Maximum 30 m
    
·
    
Wire (between the monitor station and the door station):
Type: General cable CAT-3 24 AWG
Distance: Maximum 100 m
9
VL-GM201RU
5.2. INSTALLING THE DOOR STATION
Make sure to install the door station on a flat, vertical wall.
Important information:
On the bottom surface of the door station, there is a hole to allow water to drain. Do not cover it up when installing.
1. Unscrew the hex-head screw using the longer end of the allen
wrench and remove the mounting bracket from the rear of the door
station.
2. Attach the mounting bracket to the wall using the wood screws (3.8
mm × 20 mm).
    
·
    
Before drilling, see Standard installation position of the door
station and camera range 
for installation location (P.8).
3. Connect the wires that connect to the monitor station to the terminal
by unscrewing the screws, pushing in the wires, then tightly fastening
the screws.
    
·
    
See Power cable/wire type and distance for the wire type and
distance (P.9).
    
·
    
You can change the camera angle using the camera angle control
lever. See Standard installation position of the door station and
camera range 
for details (P.8).
10
VL-GM201RU
    
·
    
If you want to connect the wires without them passing through a
hole in the wall, connect the wires by passing them through the ribs
and the wire hole.
4. Mount the door station to the mounting bracket.
5. Insert the hex-head screw using the longer end of the allen wrench.
6. Attach the bolt cover using the shorter end of the allen wrench.
    
·
    
Use protrusion on the shorter end of the allen wrench to rotate the
bolt cover until it is secure.
11
VL-GM201RU
5.3. INSTALLING THE MONITOR STATION
1. Install the mounting bracket to a wall using the wood screws (4 mm
×16 mm).
    
·
    
Remove the mounting bracket from the rear of the monitor station
beforehand.
    
·
    
Before drilling, see Standard installation position of the door
station and camera range 
for installation location (P.8).
2. Attach the power cable to the terminal. See To attach the power
cable 
for details on how to attach the power cable (P.16).
    
·
    
If you want to use your own power cable, see Power cable/wire
type and distance 
(P.9).
3. Attach the wires that connect to the door station to the terminal. See
To attach the wires for details on how to attach the wires.
    
·
    
See for the wire type and distance.
    
·
    
See the Wiring schematic diagram (P.9).
12
VL-GM201RU
Page of 80