DOWNLOAD Panasonic SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E Service Manual ↓ Size: 7.28 MB | Pages: 67 in PDF or view online for FREE

Model
SB-FS1000E SB-FC1000LE SB-FC1000RE SB-HS1000E SB-WA1000E SB-TP1000E
Pages
67
Size
7.28 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / SPEAKER SYSTEM
File
sb-fs1000e-sb-fc1000le-sb-fc1000re-sb-hs1000e-sb-w.pdf
Date

Panasonic SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E Service Manual ▷ View online

1 Safety Precautions
1.1. General Guidelines
 1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
 2. After servicing, ensure that all the protective devices such as insulation barriers, insulation papers shields are properly installed.
 3. After servicing, check for leakage current checks to prevent from being exposed to shock hazards.
1.1.1. Leakage Current Cold Check
 1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
 2. Using an ohmmeter measure the resistance value, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
Ω and 5.2Ω.
When the exposed metal does not have a return path to the chassis, the reading must be
.
Figure 1
1.1.2. Leakage Current Hot Check (See Figure 1)
 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
 2. Connect a 1.5k
Ω, 10 watts resistor, in parallel with a 0.15µF capacitors, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
 3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
 4. Check each exposed metallic part, and measure the voltage at each point.
 5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
 6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. should the measurement is outside of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and re-checked before it is returned
to the customer.
3
SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E
1.2. Caution for AC Cord
SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E
4
1.3. Before Repair and Adjustment (For SB-WA1000E-K)
Disconnect AC power, discharge Power Supply Capacitors C508 & C703 through a 10
Ω, 1W resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
 • Current consumption at AC 230 V - 240 V, 50 Hz (NO SIGNAL mode) should be 200~700 mA.
1.4. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
 • No sound is heard when the power is turned on.
 • Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
"shorted", or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
 1. Turn off the power.
 2. Determine the cause of the problem and correct it.
 3. Turn on the power once again after one minute.
Note:
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
1.5. Safety Part Information
Safety Parts List:
There are special components used in this equipment which are important for safety.These parts are marked by
in the
Schematic Diagrams & Replacement Parts List. It is essential that these critical parts should be replaced with manufacturer’s
specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of manufacturer.
Table 1
Reference No.
Part No.
Part Name & Description
Remarks
28
RGR0352G-E
REAR PANEL
[M]
T701
G4C8AGH00004
POWER TRANSFORMER
[M]
T702
G4C2CAK00001
BACK-UP TRANSFORMER
[M]
Z702
ERZV10V511CS
ZENER
[M]
RLY601
K6B2AHA00014
RELAY
[M]
RLY701
K6B1AEA00003
RELAY
[M]
F1
K5D252BLA013
FUSE
[M]
F2
K5D202BK0005
FUSE
[M]
JK701
K2AA2B000011
AC INLET
[M]
W1
REE1205-1
BROWN WIRE
[M]
W2
REE1204-1
BLUE WIRE
[M]
C508
ECKWRS102MBC
100pF
[M]
C703
ECKWRS102MBC
100pF
[M]
A11
K2CJ2DA00010
AC CORD
[M]
(GN)
A11
K2CQ2CA00006
AC CORD
[M]
(E/EE)
A11
K2CT3CA00004
AC CORD
[M]
(EB)
PCB4
REPV0128C
TRANSFORMER P.C.B.
[M]
(RTL)
5
SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E
2 Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by electricity. Such components commonly are called
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor “chip” components. The following techniques should be used to help reduce the incidence of component damage
caused by electro static discharge (ESD).
 1. Immediately before handling any semiconductor component or semiconductor-equiped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
 2. After removing an electrical assembly equiped with ES devices, place the assembly on a conductive surface such as aluminium
foil, to prevent electrostatic charge build up or exposure of the assembly.
 3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
 4. Use only an anti-static solder remover device. Some solder removal devices not classified as “anti-static (ESD protected)” can
generate electrical charge to damage ES devices.
 5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
 6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminium foil or
comparable conductive material).
 7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
Caution
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
 8. Minimize body motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the brushing
together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient to
damage an ES device).
6
SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E
Page of 67
Display

Panasonic SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E Service Manual ▷ Download

  • DOWNLOAD Panasonic SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E Service Manual ↓ Size: 7.28 MB | Pages: 67 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E Audio. Information contained in Panasonic SB-FS1000E / SB-FC1000LE / SB-FC1000RE / SB-HS1000E / SB-WA1000E / SB-TP1000E Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.