10.2.2. DVD Self-Diagnostic Function Error Code
Error
Code
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
F010
DVD Media disk
A specification value is size from the
PARENTAL
LOCK
value
of
the
appointed country.
Press [
] on main
unit for next error.
F020
DVD Media disk
There is no TT_SRPT. (RLBN is 0).
Press [
] on main
unit for next error.
F021
DVD Media disk
The number of TT_SRP is 0.
Press [
] on main
unit for next error.
F022
DVD Media disk
A specification value. It is size from the
number of TT_SRP.
Press [
] on main
unit for next error.
F023
DVD Media disk
VTSN or in agreement with VTS_TTN.
There is no SRP.
Press [
] on main
unit for next error.
F024
DVD Media disk
A specification value. It is size from
TT_SRP. PTT_Ns
Press [
] on main
unit for next error.
F030
DVD Media disk
The number of TTU_SRP is 0.
Press [
] on main
unit for next error.
F031
DVD Media disk
A specification value. It is size from the
number of TTU_SRP.
Press [
] on main
unit for next error.
F040
DVD Media disk
The number of SRP1 is 0.
Press [
] on main
unit for next error.
F041
DVD Media disk
The number of PGCI_SRP is 0.
Press [
] on main
unit for next error.
F042
DVD Media disk
A specification value. It is size from the
number of PGCI_SRP.
Press [
] on main
unit for next error.
F043
DVD Media disk
It is in agreement with Menu ID. There is
no PGCI_SRP.
Press [
] on main
unit for next error.
F050
DVD Media disk
The number of TMAP_SRP is 0.
Press [
] on main
unit for next error.
F051
DVD Media disk
A specification value. It is size from the
number of TMAP_SRP.
Press [
] on main
unit for next error.
F052
DVD Media disk
Specification TMAP_SA is 0.
Press [
] on main
unit for next error.
F053
DVD Media disk
The number of MAP_EN is 0.
Press [
] on main
unit for next error.
F060
DVD Media disk
Although C_POSIT exists, it is in PGC.
There is no PGMAP.
Press [
] on main
unit for next error.
F061
DVD Media disk
Although C_POSIT exists, it is in PGC.
There is no PGMAP.
Press [
] on main
unit for next error.
29
SA-VK950EE
Error
Code
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
F062
DVD Media disk
A specification value inside of PGC. It is
size from the number of PGes.
Press [
] on main
unit for next error.
F063
DVD Media disk
Although C_POSIT exists, it is in PGC.
There is no C_PBIT.
Press [
] on main
unit for next error.
F064
DVD Media disk
Although C_POSIT exists, it is in PGC.
The number of PGes is 0.
Press [
] on main
unit for next error.
F065
DVD Media disk
Specification A cell number is 0.‘
Press [
] on main
unit for next error.
F066
DVD Media disk
A specification value inside of PGC. It is
size from the number of Cell(s).
Press [
] on main
unit for next error.
F067
DVD Media disk
A blocked cell is present.
Press [
] on main
unit for next error.
F070
DVD Media disk
There is no NV_PACK data.
Press [
] on main
unit for next error.
F080
DVD Media disk
Under reference. There is no Cell
number.
Press [
] on main
unit for next error.
F0E0
DVD Media disk
For [used as a DFD object] a user guide.
A PGC control file < impossible.
Press [
] on main
unit for next error.
F0E1
DVD Media disk
DFD main microcomputer. Compatibility
with a DFD type < download is
impossible.
Press [
] on main
unit for next error.
F0E2
DVD Media disk
DFD download start. PGC reproduction
error.
Press [
] on main
unit for next error.
F0E3
DVD Media disk
Waiting for the completion of DFD
download. PGC reproduction error.
Press [
] on main
unit for next error.
F0E4
DVD Media disk
At the time of DFD download AVDEC.
Press [
] on main
unit for next error.
F0E5
DVD Media disk
It is the farm file lead error at the time of
DFD download.
Press [
] on main
unit for next error.
F0E6
DVD Media disk
DFD alteration check error of the read
firmware.
Press [
] on main
unit for next error.
F0F0
DVD Media disk
There is no farm file used as a DFD
object and it is downloading needlessly.
Press [
] on main
unit for next error.
F0F1
DVD Media disk
The firware which is in agreement with
DFD
download
conditions
<
unnecessary.
Press [
] on main
unit for next error.
F103
Illegal highlight Position
Big possibility of disc specification
violation during highlight display
Press [
] on main
unit for next error.
F4FF
Force initialize failure
(time out)
Timeout when force initialization fails
Press [
] on main
unit for next error.
30
SA-VK950EE
Error
Code
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
F500
DSC error
DSC (IC8251) stops in the occurrence of
servo error (startup, focus error, etc.)
Press [
] on main
unit for next error.
F501
DSC not Ready error
DSC-system computer communication
error (Communication failure caused by
idling of DSC)
Press [
] on main
unit for next error.
F502
DSC Time out error
Similar as F500
Press [
] on main
unit for next error.
F503
DSC communication
Failure
Communication
error
(result
error
occurred
although
communication
command was sent)
Press [
] on main
unit for next error.
F504
Abnormal adjusting DSC
data slice offset
Press [
] on main
unit for next error.
F505
DSC Attention error
Similar as F500
Press [
] on main
unit for next error.
F506
Invalid media
Disc is flipped over, TOC unreadable,
incompatible disc media
Press [
] on main
unit for next error.
F600
Access failure to
management information
caused by demodulation
error
Operation stopped because navigation
data is not accessible caused by the
demodulation defect
Press [
] on main
unit for next error.
F601
Indeterminate sector ID
requested
Operation
stopped
caused
by
the
request to access abnormal ID data
Press [
] on main
unit for next error.
F602
Access failure to LEAD-
IN caused by
demodulation error
LEAD IN data unreadable
Press [
] on main
unit for next error.
F603
Access failure to
KEYDET caused by
demodulation error
Access failure to CSS data of disc
Press [
] on main
unit for next error.
F610
ODC abnormality
No permission for command execution
Press [
] on main
unit for next error.
F611
No CRC OK for a
specific time (CD)
Access failure to seek address in CD
series
Press [
] on main
unit for next error.
F612
No CRC OK for a
specific time (DVD)
Access failure to ID data in DVD series
Press [
] on main
unit for next error.
F620
Laser safeguard: high
temperature condition
High temperature of the laser guide unit
(OPU unit)
Press [
] on main
unit for next error.
F621
Laser safeguard: circuit
failure condition
Circuitry failure of the laser guide unit
(OPU unit)
Press [
] on main
unit for next error.
F700
MBX overflow
When replying message to disc manager
Press [
] on main
unit for next error.
F701
Message command
does not end
Next message is sent before replying to
disc manager
Press [
] on main
unit for next error.
F702
Message command
changes
Message is changed before it is sent as
a reply to disc manager
Press [
] on main
unit for next error.
31
SA-VK950EE
Error
Code
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
F880
Task number is not
appropriate
Message coming from a non-existing
task
Press [
] on main
unit for next error.
F890
Sending message when
message is being sent to
AV task
Sending message to AV task
Press [
] on main
unit for next error.
F891
Message couldn’t be
sent to AV task
Begin sending message to AV task
Press [
] on main
unit for next error.
F893
FLASH ROM IC problem FLASH ROM IC installed is not operating
properly (Neccessary replacement of
FLASH ROM IC) or firmware problem
Press [
] on main
unit for next error.
F894
EEPROM abnormality
EEPROM IC installed is not operating in
normal condition (EEPROM contains
neccessary data)
Press [
] on main
unit for next error.
F895
Region setting
abnormality
Firm version agreement check for factory
preset setting failure prevention. Check
region setting & re-initialize
Press [
] on main
unit for next error.
F896
No existence model
Firm version agreement check for factory
preset setting failure prevention
Press [
] on main
unit for next error.
F897
Initialize is not
completed
Initialize completion check for factory
preset setting failure prevention
Press [
] on main
unit for next error.
F898
Disagreement of
hardware and software
Unsuitable
combination
of
AV
DECORDER, SDRAM and FLASH ROM
(firmware)
Press [
] on main
unit for next error.
F8A0
Message command is
not appropriate
Message command is not suitable
Press [
] on main
unit for next error.
Note:
An error code will be canceled if a power supply is turned OFF.
*1: CPPM is the copy guard function beforehand written in the disk for protection of copyrights.
10.2.3. Optical Pickup Breakdown Diagnosis
This unit is equipped with the optical pickup self-diagnosis function and the tilt adjustment check function. Follow the procedure
described below during repair in order to perform self-diagnosis and tilt adjustment effectively. Especially when “NO DISC” is
displayed, be sure to apply the self-diagnosis function before replacing with an optical pickup. Replacement of optical pickup
generally requires when the present value of laser drive exceeds 45 (DVD) or 45 (CD).