 1. Enter into self-diagnostic mode.
 2. Errors are stored in the unit memory. To clear memory, press and hold down "STOPn/-DEMO” button for 5 seconds or more
during self-diagnostic mode. The message, “CLEAR” appears on the display when memory is erased, and the unit displays the
message, “T”.
Memory is not affected by turning off the power or unplugging the socket.
Be sure to clear memory after repair is completed.
 3. Press "STOPn/-DEMO” button. A symbol of self-diagnostic is indicated on the display if an error is found. If several errors are
found, a respective indication is displayed when "STOPn/-DEMO" button is pressing repeatedly. (e.g. H01
→ CD F15 → F01)
If no error is found, only "T " indication is displayed and remains unchange even if "STOPn/-DEMO" button is pressed.
13.3. Displaying Self-Diagnostic Results
(Cassette Deck Section) (H01, H02, H03, F01, F02)
 1. Enter the self-diagnostic mode, following the instructions described in [13.1.1 Setting of the Self-Diagnostic Mode].
 2. Insert a normal-positioned music tape with erase prevention niches on both Sides A and B. Press [TAPE
] button to activate
the TPS operation so that the tape automatically stops at an interval between music selections.
 3. Press [STOPn /-DEMO] and [TAPE
] buttons together on the remote controller. (Recording does not start.)
 4. Then, insert a Cr02-positioned blank cassette tape with an erase prevention niche of Side A or B set to the left side.
 5. Press [
/FF/
] button. The tape will be forwarded and automatically stop after two seconds.
 6. Remove the cassette tape, and set the other side.
 7. Press [
/REW/
] button. The tape will be rewound and automatically stops after two seconds.
 8. Press [STOPn/-DEMO] button on the unit.
If an error is found, a self-diagnostic key appears on the display.
If several errors are found, the display shows these keys when [STOPn/-DEMO] button is pressed repeatedly. (Ex.: H01 - H02
- F01 - H01)
If no error is found, only the message, “T” appears on the display.
(*1) TPS operation (music search) detects the blank sections between music selections. Therefore, do not use tapes with the
following conditions:
     ·    A blank section that lasts only 4 seconds or less.
     ·    No blank sections (recording through microphones, etc.).
     ·    Music selections that have extremely low pitches or prolonged silent sections (such as classical music).
     ·    and/or Music recorded with fade in/out effect.
13.4. Error Code Table
13.4.1. Error code for Power Supply
Error Code
Abnormal Items
Possible Cause
F61
POWER AMP output
abnormal
During normal operation, if DCDET becomes “L”, normal POWER OFF process shall not be
executed, PCONT shall be switched to “L” immediately. “GOODBYE” shall not be display but
the error display F61 is displayed instead. 2 seconds after the F61 displayed, ECONO shall be
set to “L” and FL display shall be turned off. The error content shall be memorized when
theabnormality occurs and can be display in the C-mecha self-diagnostic mode described later.
13.4.2. Error codes for CD Mechanism
Error Code
Abnormal Items
Possible Cause
F15
CD REST SW abnormal
CD traverse position intial setting operation failsafe counter (1000 ms) waiting for REST SW to
turn on. Error No. shall be clear by force or during coldstart.
F26
CD servo LSI command
signal abnormal
CD function DTMS command, after system setting, If SENSE = ‘L’ cannot be detected.
Memory shall contain F26 code. After Power on, CD function shall continue, error shall occur
“NO DISC”.
Error No. shall be clear by force or coldstart.
F28
DISC LOAD abnormal
While going to play position, if failsafe counter is finished and switch no change or switch
target condition was not achieve, this error shall be memorized. Next time mechanism
operates, it shall do coldstart.
Error No. shall be clear by force or coldstart.
F29
DISC unload abnormal
While going to play position, if failsafe counter is finished and switch no change or switch
target condition was not achieve, this error shall be memorized. Next time mechanism
operates, it shall do coldstart.
Error No. shall be clear by force or coldstart.
53
SA-PM41E / SA-PM41EB / SA-PM41EG
Error Code
Abnormal Items
Possible Cause
F27
Slide operation abnormal
During vertical operation, if failsafe timer is finished and switch no change or switch target
condition was not achieve, this error shall be memorized. Next time mechanism operates, it
shall do coldstart.Error No. shall be clear by force or coldstart.
F17
Down SW abnormal
During vertical operation going to the bottom position, if failsafe timer is finished and switch
no change or switch target condition was not achieve, this error shall be memorized. The
Next time mechanism operates, it shall do mechanism initialization.Error No. shall be clear by
force or coldstart.
F22
Loading Mode / Mecha
abnormal
During mecha initialization, Loading mode mechanism abnormal, normal operation cannot be
achieve. The next time mechanism operates, it shall do mechanism initialization.Error No.
shall be clear by force or coldstart.
13.4.3. Error codes for Deck Mechanism
Error Code
Abnormal Items
Possible Cause
H01
MODE SW abnormal
Normal operation during mecha transition, MODE SW abnormal is memorised. The content
of abnormality can be confirmed in the abnormal detection mode explained in the later
section.
H02
REC INH SW abnormal
The content of abnormality can be confirmed in the abnormal detection mode explained in
the later section.
H03
HALF SW abnormal
F01
Reel pulse abnormal
F02
TPS abnormal
13.5. Deck Mechanism Self-Diagnostic Mode
 1. A Cr02-positioned blank cassette tape with an erase prevention niche on either Side A or B.
 2. A normal-positioned music tape with erase prevention niches on both Sides A and B. Both tapes are halfway forwarded in
advance.
 3. The remote controller that comes with this unit.
No.
Operation Procedures
Micon operation & processing
1
C-mecha Abnormal Detection shall be
executed for DECK 1 only.
Check that all DECK mechanism leaf SW are in OFF state.
2
[
] key is pressed, after loading in a
NORMAL type cassette with the recording tab
on the left side removed.
FF shall be executed for 2 sec, afterwhich STOP.
Check the following.
{ F.REC INH SW } is OFF
{ R.REC INH SW } is ON
{ HALF SW } is ON
Reel pulse toggles between H & L.
3
[
] key is pressed, after loading a NORMAL,
CrO2, METAL type cassette with the recording
tab on the right side removed.
REW shall be executed for 2 sec, afterwhich STOP.
Check the following.
{ F.REC INH SW } is ON
{ R.REC INH SW } is OFF
{ HALF SW } is ON
Reel pulse toggles between H & L.
4
[TAPE
] Key is pressed, after loading in a
NORMAL, CrO2, METAL type cassette (
cassette for TPS checking purposes and with
both recording tabs intact ).
TPS operation is executed. Check the following.
{ F.REC INH SW } is ON
{ R.REC INH SW } is ON
{ HALF SW } is ON
TPS signal changes.
After checking TPS, it shall STOP.
If TPS checking is completed at TAPE END, it is considered as TPS
abnormal.
5
[REC] key is pressed, after loading in a
NORMAL type cassette ( with both recording
tabs intact )
REC operation shall not be executed.
Check the following.
{ F.REC INH SW } is ON
{ R.REC INH SW } is ON
{ HALF SW } is ON
6
Self-diagnostic mode is stopped by pressing
the [CLEAR n] Key.
LCD shall display the abnormality item code, when the STOP key is pressed,
it shall display the abnormality item code in the following sequence.
[ T H 0 1 ] [ T H 0 2 ] [ T H 0 3 ]
7
To clear all the abnormalities in the memory,
press the [CLEAR n] Key for more than 5 Sec
while the self-diagnostic mode is stopped.
At this time, all the abnormalities item in the memory is cleared and is
displayed on the LCD.[ C L E A R ] display for 1 Sec. then,[ T ] is displayed.
8
To cancel the self-diagnostic mode press the
[POWER] Key.
POWER is OFF.At the next POWER ON, normal operation shall be executed.
     ·    If RAM check error occurs during microcomputer reset, COLDSTART shall be executed and all the error memory shall be
cleared during RAM initialization.
13.6. Changer Reliability Test Mode
 1. Doctor mode ON.
 2. Press [2] button on the remote control. it enters into ageing mode.
54
SA-PM41E / SA-PM41EB / SA-PM41EG
     ·    During this series of operation, the number of its operation shall be shown in the alphanumeric display repeatedly.
It shall start from [ _ _ 00001]
     ·    It shall move up one counter when step 1~8 of the above operations end.
It shall display [ _ _ 00000] after [ _ _ 99999] has been reached.
     ·    Press POWER key, tray return to PLAY position and then POWER is OFF.
During test mode, if mecha operation encounters abnormality or time over , retry operation shall be done but aging test mode shall
stop.
Ageing process:
 1. Tray 1 open.
 2. It waits for 1 second (Note: Do not put any disc into the tray).
 3. Tray 1 close.
 4. TOC READ (Reading incomplete).
 5. Tray 2 open and repeat process 1 to 4. (Process repeat until Tray 5).
 6. Tray check.
 7. Whole process complete (Counter on FL increase by 1).
Note: To exit ageing mode, press [
POWER] button. The unit will power down. Do not unplug the power cord until FL display
shows “GOODBYE”. This is to avoid tray jam problem.
Display Example:
[00000T3OP]
...TRAY OPEN
[00000T3CL]
...TRAY CLOSE
[00000T3RE]
...TOC READING
[00000T3CH]
...TRAY CHANGING
13.7. Changer Operation Checking
 1. Doctor mode ON.
 2. press [DISC] key to ON
Current disc setting shall be tray 1
 a. tray 1 load, tray 2 open then close
 b. tray 1 load, tray 3 open then close
 c. tray 1 load, tray 4 open then close
 d. tray 1 load, tray 5 open then close
 e. tray 1 load, while playing CD check mode 4 disc then close
 f. 
tray 1 stop unload
 g. CD check mode and then close
 h. tray 1 load
 i. 
after the above process, [CHNGR_OK] shall be displayed
     ·    During this series of operation, the number of its operation shall be shown in the alphanumeric display repeatedly.
It shall start from [ _ _ 00001]
     ·    It shall move up one counter when step 1~8 of the above operations end.
It shall display [ _ _ 00000] after [ _ _ 99999] has been reached.
     ·    Press POWER key, tray return to PLAY position and then POWER is OFF.
During test mode, if mecha operation encounters abnormality or time over , retry operation shall be done but aging test mode shall
stop
13.8. CR16 Mechanism Ageing Mode
To enter into ageing mode:
 1. Enter a Doctor mode.
 2. Press [2] button on the remote control. It enters into ageing mode.
Ageing process:
 1. Tray 1 open.
 2. It waits for 1 second (Note: Do not put any disc into the tray).
 3. Tray 1 close.
55
SA-PM41E / SA-PM41EB / SA-PM41EG
 4. TOC READ (Reading incomplete).
 5. Tray 2 open and repeat process 1 to 4. (Process repeat until Tray 5).
 6. Tray check.
 7. Whole process complete (Counter on FL increase by 1).
Note: To exit ageing mode, press [
POWER] button. The unit will power down. Do not unplug the power cord until FL display
shows “GOODBYE”. This is to avoid tray jam problem.
Display Example:
[00000T3OP]
...TRAY OPEN
[00000T3CL]
...TRAY CLOSE
[00000T3RE]
...TOC READING
[00000T3CH]
...TRAY CHANGING
56
SA-PM41E / SA-PM41EB / SA-PM41EG
Page of 127
Display