1 Safety Precautions
1.1. General Guidelines
 1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
 2. After servicing, ensure that all the protective devices such as insulation barriers and insulation papers shields are properly
installed.
 3. After servicing, check for leakage current checks to prevent from being exposed to shock hazards.
1.1.1. Leakage Current Cold Check
 1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
 2. Using an ohmmeter measure the resistance value, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
and 5.2M
.
When the exposed metal does not have a return path to the chassis, the reading must be
.
1.1.2. Leakage Current Hot Check (See Figure 1)
 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
 2. Connect a 1.5k
, 10 watts resistor, in parallel with a 0.15µF capacitor, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
 3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
 4. Check each exposed metallic part, and measure the voltage at each point.
 5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
 6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. Should the measurement is out of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
Fig. 1
5
SA-NC9EB
1.2. Caution for AC Mains Lead
6
SA-NC9EB
1.3. Before repair and adjustment
Disconnect AC power, discharge Power Supply Capacitors C5951 through a 10
, 5W resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 230~240V, 50 Hz in NO SIGNAL mode (volume min at CD mode) should be ~ 500mA.
1.4. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
    • 
• 
• 
• 
No sound is heard when the power is turned on.
    • 
• 
• 
• 
Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
 1. Turn off the power.
 2. Determine the cause of the problem and correct it.
 3. Turn on the power once again after one minute.
Note :
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
1.5. Safety Parts Information
Safety Parts List:
There are special components used in this equipment which are important for safety.
These parts are marked by
in the Schematic Diagrams & Replacement Parts List. It is essential that these critical parts
should be replaced with manufacturer’s specified parts to prevent shock, fire or other hazards. Do not modify the original design
without permission of manufacturer.
Table 1
Reference No.
Part No.
Part Name & Description
Remarks
360
RAE2024Z-S
TRAVERSE UNIT
[M]
A2
K2CT3CA00004
AC CORD
[M]
F1
K5D252BLA013
2.5A FUSE
[M]
FP5920
K5G103A00019
FUSE PROTECTOR
[M]
FP5940
K5G103A00019
FUSE PROTECTOR
[M]
FP5950
K5G502A00039
FUSE PROTECTOR
[M]
JK5950
K2AA2B000011
JK AC INLET
[M]
L5271
G0B9R5K00001
COIL
[M]
L5272
G0B9R5K00001
COIL
[M]
L5371
G0B9R5K00001
COIL
[M]
L5372
G0B9R5K00001
COIL
[M]
L5471
G0B9R5K00001
COIL
[M]
L5472
G0B9R5K00001
COIL
[M]
L5950
ELF15N035AN
LINE FILTER
[M]
L5951
ELF15N035AN
LINE FILTER
[M]
R5271
ERJ3GEYJ102V
1K 1/16W
[M]
RL5950
K6B1AEA00003
POWER RELAY
[M]
T5950
G4CYAYY0 0141
THERMISTOR
[M]
T5951
G4C2AAJ00005
BACK-UP TRANSFORMER
[M]
Z5950
ERZV10V511CS
ZENER
[M]
7
SA-NC9EB
2 Handling Precautions for Traverse Unit
The laser diode used inside optical pickup could be destroyed due to static electricity as a potential difference is caused by
electrostatic load discharged from clothes or human body. Handling the parts carefully to avoid electrostatic destruction during
repair.
2.1. Handling Optical Pickup
 1. Do not impact on optical pickup as the unit structurally uses an extremely precise technology.
 2. Short-circuit the flexible cable of optical pickup remove from the circuit board using a short-circuit pin or clip in order to prevent
laser diode from electrostatic destruction (Refer to Fig. 2.1 and Fig. 2.2)
 3. Do not handle flexible cables forcibly as this may cause snapping. Handle the parts carefully (Refer to Fig. 2.1)
 4. A new optical pickup is equipped with an anti-static flexible cable. After replacing and connecting to the flexible board, cut the
anti-static flexible cable. (Refer to Fig. 2.1)
Fig. 2.1
2.2. Replacing Precautions for Optical Pickup Unit
CD/DVD Optical Pickup
The optical pickup by which part supply was carried out attaches the short clip to the flexible board for laser diode electrostatic
discharge damage prevention. Please remove the short clip and be sure to check that the short land is open, before connecting.
(Please remove solder, when the short land short-circuits.)
2.3. Grounding for Preventing Electrostatic Destruction
 1. Human body grounding
Use the anti-static wrist strap to discharge the static electricity accumulated in your body. (Refer to Fig. 2.2)
 2. Work place grounding
Place a conductive material (conductive sheet) or ironboard where optical pickup is placed. (Refer to Fig. 2.2)
Note :
Keep your clothes away from optical pickup as wrist strap does not release the static electricity charged in clothes.