DOWNLOAD Panasonic SA-NC6EE Service Manual ↓ Size: 6.81 MB | Pages: 81 in PDF or view online for FREE

Model
SA-NC6EE
Pages
81
Size
6.81 MB
Type
PDF
Document
Simplified Service Manual
Brand
Device
Audio / DVD STEREO SYSTEM
File
sa-nc6ee.pdf
Date

Panasonic SA-NC6EE Simplified Service Manual ▷ View online

2 Safety Precautions
Note: With reference to page 5~7 (section 1) of original service manual for SA-NC6EB-K. Below is the updates.
2.1. General Guidelines
 1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
 2. After servicing, ensure that all the protective devices such as insulation barriers and insulation papers shields are properly
installed.
 3. After servicing, check for leakage current checks to prevent from being exposed to shock hazards.
2.1.1. Leakage Current Cold Check
 1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
 2. Using an ohmmeter measure the resistance value, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
Ω and 5.2MΩ.
When the exposed metal does not have a return path to the chassis, the reading must be
.
Fig. 1
2.1.2. Leakage Current Hot Check (See Figure 1)
 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
 2. Connect a 1.5k
Ω, 10 watts resistor, in parallel with a 0.15µF capacitor, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
 3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
 4. Check each exposed metallic part, and measure the voltage at each point.
 5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
 6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. Should the measurement is out of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
2.2. Before repair and adjustment
Disconnect AC power, discharge Power Supply Capacitors C5951 through a 10
Ω, 5W resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 230 V, 50 Hz in NO SIGNAL mode (volume min at CD mode) should be ~ 500mA.
2.3. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
     ·    No sound is heard when the power is turned on.
     ·    Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
 1. Turn off the power.
 2. Determine the cause of the problem and correct it.
5
SA-NC6EE
 3. Turn on the power once again after one minute.
Note :
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
2.4. Safety Parts Information
Safety Parts List:
There are special components used in this equipment which are important for safety.
These parts are marked by
in the Schematic Diagrams & Replacement Parts List. It is essential that these critical parts
should be replaced with manufacturer’s specified parts to prevent shock, fire or other hazards. Do not modify the original design
without permission of manufacturer.
Table 1
Reference No.
Part No.
Part Name & Description
Remarks
A2
K2CQ2CA00007
AC CORD
[M]
C5251
F2A1V4710036
470 35V
[M]
C5252
F2A1V4710036
470 35V
[M]
C5351
F2A1V4710036
470 35V
[M]
C5352
F2A1V4710036
470 35V
[M]
C5512
F2A1V1020084
1000 35V
[M]
C5513
F2A1V1020084
1000 35V
[M]
C5951
ECQU2A104MLC
0.1
[M]
F1
K5D162BLA013
FUSE
[M]
FP5920
K5G702A00009
FUSE
[M]
FP5940
K5G702A00009
FUSE
[M]
FP5950
K5G502A00039
FUSE PROTECTOR
[M]
JK5950
K2AA2B000011
JK AC INLET
[M]
L5950
ELF15N035AN
LINE FILTER
[M]
L5951
ELF15N035AN
LINE FILTER
[M]
RL5950
K6B1AEA00003
MAGNETRELAYS
[M]
T5950
G4CYAYY00141
TRANSFORMER
[M]
T5951
G4C2AAJ00005
BACK-UP TRANSFORMER
[M]
Z5950
ERZV10V511CS
ZENER
[M]
6
SA-NC6EE
3 Precaution of Laser Diode
Note: With reference to page 9 (section 3) of original service manual for SA-NC6EB-K. Below is the updates.
Caution :
This product utilizes a laser diode with the unit turned "ON", invisible laser radiation is emitted from the pick up lens.
Wavelength : 785 nm(CD)/662 nm(DVD)
Maximum output radiation power from pick up : 100 µW/VDE
 1. Do not disassemble the optical pick up unit, since radiation from exposed laser diode is dangerous.
 2. Do not adjust the variable resistor on the pick up unit. It was already adjusted.
 3. Do not look at the focus lens using optical instruments.
 4. Recommend not to look at pick up lens for a long time.
CAUTION!
THIS PRODUCT UTILIZES A LASER.
USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT
IN HAZARDOUS RADIATION EXPOSURE.
n Use of Caution Labels
4 Accessories
Note: With reference to page 11 (section 5) of original service manual for SA-NC6EB-K. Below is the updates.
AC power
supply cord
7
SA-NC6EE
5 Operation Procedures
Note: With reference to page 12~14 (section 6) of original service manual for SA-NC6EB-K. Below is the updates.
8
SA-NC6EE
Page of 81
Display

Click on the first or last page to see other SA-NC6EE service manuals if exist.