This unit is equipped with the self-diagnosis function, which
displays an error when it occurs, for use during servicing.
14.1. Automatic Displayed Error
Codes
14.1.1. Automatic Display Function
For a power unit error, the code is automatically displayed.
F61:
Automatically displayed on the LCD of
the player.
Fig. 14-1
14.1.2. Re-Display
    
·
    
For F61 Display
     − 
− 
− 
− 
When the code, F61 is displayed, the power is
automatically turned off.
     − 
− 
− 
− 
The code, F61 is displayed for three seconds, and then
the current time appears.
     − 
− 
− 
− 
To retrieve the code, turn on the power button so that
the code F61 appears, however, is switched to time
display
after
three
seconds,
and
the
power
is
automatically turned off.
14.1.3. Description of Error Code
14.1.3.1. F61
    
·
    
State, Condition
When the power is turned on, the unit is automatically
turned off. The power does not turn on.
    
·
    
Cause, Troubleshooting
Power circuit system failure and/or direct current flown to
speaker terminal
Identify the cause and replace with new parts.
14.2. Memorized Error Codes
14.2.1. Activating Self-Diagnosis Function
and Displaying Method
 1. Turn on the power.
 2. Select DVD/CD function. With no DVD/CD inserted in the
player, press and hold down the
button for at least two
seconds, and press the F_SKIP
button for at least two
seconds in order to display “T___________”.
 3. Press the
button. If a memorized error is detected, the
result of self diagnosis is displayed. (Ex.: T H15) (See table
below)
If several errors are detected, press the
button to display
each.
Fig. 14-2
14.2.2. Re-Display
    
·
    
Press the power button to turn off the power, and then turn
on the power.
    
·
    
The details of self diagnosis are stored in the unit memory.
To retrieve them, follow the procedure described the above,
“Activating
Self-Diagnosis
Function
and
Displaying
Method”.
14.2.3. Deleting Details of Self Diagnosis
    
·
    
After repair, press and hold down the
button for at least
five seconds, “T___ --- __” appears for a second and then
“T________”
appears.
(Deleting
the
details
of
self
diagnosis)
    
·
    
After repairing errors, be sure to delete the details of self
diagnosis.
14 Self-Diagnosis Function
Error Code
State, Conditon
Cause, Troubleshooting
H15
The disc tray cannot be opened: it closes spontaneously.
Disc tray open/close detection switch (S901, S902) failure.
(Check and replace)
H16
The disc tray cannot be closed: it opens spontaneously.
21
SA-HT520EE
14.3. Mode Table 1
Following modes are available with combinations of the pressed buttons on the player and on the remote controller unit.
Player
Remote controller
unit
Usage
button
0
Error code display (Refer to the item, 15.4. DVD Error Code Description)
5
Tilt adjustment
6
Area number and broadcasting system check
7
MICRO - P & Firmware Version.
DISPLAY
DVD laser drive current check
3
CD laser drive current check
PAUSE
Writing of laser drive current value after replacement of optical pickup
(Do use this function only when optical pickup is replaced.)
Initialization of the player (factory setting is restored.)
Used after replacement of micro-computer and its peripherals and printed circuit board.
14.4. DVD/CD Self-Diagnosis Error Code Description
Error Code
Meaning
Details
U. H. Error
U11
Focus servo failure
H01
Tray loading failure
H02
Spindle servo failure
(Spindle servo, DSC, SP motor, CLV servo failure)
H03
Traverse motor failure
H04
Tracking servo error
H05
Seek timeout failure
DSC system
F500
DSC failure
DSC stops due to servo failure.
(Startup, focus failure, etc.)
F501
DSC not Ready failure
Communication failure between DSC and system computer
(No communication because DSC does not move)
F502
DSC Time out failure
See F500.
F503
DSC communication failure
Communication
failure
(Result
failure
occurs
after
communication
command is transmitted.)
F505
DSC Attention Error
See F500.
F506
Invalid media
Disc is placed upside down; TOC is unreadable or invalid disc is inserted.
ODC system
F600
Unable to obtain control information due to form
recovery failure
Operation stops because navigation data cannot be obtained due to form
recovery system failure.
F601
Illegal sector ID requested
Operation stops because access of illegal ID data is requested.
F602
Unable to obtain LEAD IN due to form recovery
failure
Unable to read LEAD IN data
F603
Unable to obtain KEY DET due to form recovery
failure
Unable to obtain CSS data
F610
ODC failure
No permission of command issue
F611
No CRC OK appearing for a certain time
Unable to obtain seek address at CD system
F612
No CRC OK appearing for a certain time
Unable to obtain ID data at DVD system
Disc Code
F103
Ilegal highlight position
Disc standard is possibly illegal when highlight is displayed.
IIC Error
F4FF
Forced initialization failure (Time out)
Micro-computer Error
F700
MBX overflow
When replying a message to Disc Manager
F701
Unable to complete a message command
A message is issued before replying to Disc Manager.
F702
Change in a message command
A message is issued before replying to Disc Manager.
F880
Unsuitable task number
When a message arrives from not existing task
F890
A message is sent during AV task transmission
During transmission of a message to AV task
F891
Unable to transmit a message to AV task
When transmission of a message to AV task starts
F893
FROM altered
F894
EEPROM failure
F8A0
Unsuitable message command
When transmission of a message to AV task starts
22
SA-HT520EE
14.5. Error Codes Stored During No Play
Error Code
Meaning
System Computer Item
Setting Task
Internal error in system
computer
F0BF
6)
Unable
to
replay
due
to
physical
layer
identification failure
PCND_NOPLAY_
PHYSICAL 0x50
Drive
Manager
0xD0BF
F0C0
8) DVD: Unable to replay due to no DVD
Video/Audio/VR
PCND_NOPLAY_
VIDEO 0x70
Disc
Manager
0xD0C0
F0C1
9) DVD: Prohibited due to illegal regional code
PCND_NOPLAY_
RCD 0x80
Disc
Manager
0xD0C1
F0C2
A) DVD: No replay due to PAL system
PCND_NOPLAY_
PAL 0x90
Disc
Manager
0xD0C2
F0C3
B) DVD: All title replay prohibited in parental setting PCND_NOPLAY_
PTL 0xA0
Disc
Manager
0xD0C3
F0C4
C) VCD: Prohibited due to PHOTO CD format
PCND_NOPLAY_
PHOTOCD 0xB0
Disc
Manager
0xD0C4
F0C5
D) VCD/CD: Prohibited due to CD-ROM without
CD-DA
PCND_NOPLAY_
CDROM 0xC0
Disc
Manager
0xD0C5
14.6. Mode Table 2
Following modes are available with combinations of the pressed buttons on the player and on the remote controller unit.
Item
Operational Condition
and Key Function
Details
Display
To Exit Mode
Jitter display
While
the
player
is
stopped and no disc is
inserted,
press
and
hold
down
the
button on the player
and
the
number
button,
“5”
on
the
remote controller unit.
Jitter display
Measures
and
displays
jitter.
Measurement
is
repeated
every
second. Read error counter starts at 0
at the mode setting, and increased by
one as data read fails at target block. A
small defect is allowed to correct by
retry. Any possibility is counted as one
increment. Repetitive errors after retry
increase by two levels or more.
J
*1
xxx
*2
_yyy
*3
_zz
*4
*1
: Jitter display mode
*2
: Jitter measurement value
*3
: Read error counter
*4
: Focus driving value
Values are shown to one decimal place
in the decimal digit.Focus driving value is
displayed in the hexadecimal digit.
Press
the
STOP
or
OPEN button.
Error code display
While
the
player
is
stopped and no disc is
inserted,
press
and
hold
down
the
button on the player
and
the
number
button,
“0”
on
the
remote controller unit.
Error code display
Displays the latest error code stored in
EEPROM.
DVDnn_F---
*nn: Error history
*--: Error number
Automatically
exits the mode
after
five
seconds.
Measurement
of
laser
current
electricity initialization
value
While
the
player
is
stopped and no disc is
inserted,
press
and
hold
down
the
button on the player
and the
button on
the remote controller
unit.
Measurement
of
laser
current
electricity initialization value
Memorizes each initialization value of
DVD and CD in EEPROM.
DO
*1
_034
*2
_028
*3
*1
: Laser current electricity measurement
mode
*2
: DVD current electricity value
*3
: CD current electricity value
Values are shown in the decimal digit.
The above example indicates that the
current electricity initialization value is
34mA at DVD laser and 28mA at CD
laser when laser is turned on.
Automatically
exits the mode
after
five
seconds.
Measurement of DVD
laser
current
electricity
While
the
player
is
stopped and no disc is
inserted,
press
and
hold
down
the
button on the player
and
the
DISPLAY
button on the remote
controller unit.
Measurement of DVD laser current
electricity
Measures DVD laser current electricity
and displays the result together with
the
initialization
value
stored
in
EEPROM. After measurement, DVD
laser is lit till the power is turned off (or
goes off when the primary power is
turned off).
DD
*1
_034
*2
_032
*3
*1
: DVD laser current electricity
measurement mode
*2
: Current electricity initialization value
stored in EEPROM
*3
: Present value of current electricity
Values are shown in the decimal digit.
The above example indicates that the
current electricity initialization value is
34mA and its present value is 32mA.
Automatically
exits the mode
after
five
seconds.
23
SA-HT520EE
Item
Operational Condition
and Key Function
Details
Display
To Exit Mode
ADSC internal RAM
display
While
the
player
is
stopped and no disc is
inserted,
press
and
hold
down
the
button on the player
and the number button
“1” or “2” on the remote
controller unit.
ADSC internal RAM display
Reads and displays the RAM value
inside ADSC. The address is renewed
when the CLEAR key is pressed so
that the values at eleven points appear.
A
*1
_0FA
*2
_6901
*3
*1
:ADSC internal RAM display mode
*2
: Address
*3
: RAM value at displayed address
Values are shown in the hexadecimal
digit. The above example indicates that
ADSC value at the address, 0FAh is
6901h.
Press
the
STOP
or
OPEN button.
Measurement of CD
laser
current
electricity
While
the
player
is
stopped and no disc is
inserted,
press
and
hold
down
the
button on the player
and the number button
“3”
on
the
remote
controller unit.
Measurement
of
CD
laser
current
electricity
Measures CD laser current electricity
and displays the result together with
the
initialization
value
stored
in
EEPROM.
After
measurement,
CD
laser is lit till the power is turned off (or
goes off when the primary power is
turned off).
DC
*1
_028
*2
_026
*3
*1
: CD laser current electricity
measurement mode
*2
: Current electricity initialization value
stored in EEPROM
*3
: Present value of current electricity
Values are shown in the decimal digit.
The above example indicates the current
electricity initialization value is 28mA and
its present value is 26mA when laser is
turned on.
Automatically
exits the mode
after
five
seconds.
User initialization
While
the
player
is
stopped and no disc is
inserted,
press
and
hold
down
the
button on the player
and the number button
on the remote
controller unit.
User initialization
The user setting recovers the factory
setting.
“INITIALIZED”
None
Region display
While
the
player
is
stopped and no disc is
inserted,
press
and
hold down the
button on the player
and
the
number
button,
“6”
on
the
remote controller unit.
Region display
__w
*1
_x
*2
y
*3
_zzz
*4
*1
: Region number
*2
: N; no PAL/P; PAL
*3
: N; NTSC/6; PAL60
*4
: Panel computer jumper information
Automatically
exits the mode
after
five
seconds.
Firm version display
While
the
player
is
stopped and no disc is
inserted,
press
and
hold
down
the
button on the player
and
the
number
button,
“7”
on
the
remote controller unit.
Firm version display
rrr
*1
_xx
*2
y
*3
zzz
*4
*1
: Panel computer release number
*2
: System computer generation
*3
: System computer model type
*4
: System computer release number
Automatically
exits the mode
after
five
seconds.
Region
and
firm
version display
While
the
player
is
stopped and no disc is
inserted,
press
and
hold
down
the
button on the player
and
the
number
button,
“8”
on
the
remote controller unit.
Region and firm version display
_r
*1
__xx
*2
y
*3
zzz
*4
*1
: Region number
*2
: System computer generation
*3
: System computer model type
*4
: System computer release number
Automatically
exits the mode
after
five
seconds.
Usage time 1
While
the
player
is
stopped and no disc is
inserted,
press
and
hold
down
the
button on the player
and the
button on
the remote controller
unit.
Usage time 1
Laser usage time
Measures each for DVD and CD
respectively.
T1_1234_5678
The numbers in the left show usage time
for DVD laser and those in the right for
CD laser. The four-digit number is shown
by the ten hours in the decimal digit. The
number after 0000 is 9999.
Automatically
exits the mode
after
five
seconds.
Usage time 1 reset
While the usage time 1
is displayed, press and
hold
down
the
button on the player
and the
button on
the remote controller
unit.
Usage time 1 reset
Laser usage time‘
Resets both for DVD and CD at once.
T1_0000_0000
Automatically
exits the mode
after
five
seconds.
24
SA-HT520EE
Page of 104
Display

Click on the first or last page to see other SA-HT520EE service manuals if exist.