Panasonic SA-AK350E / SA-AK350EB / SA-AK350EG Service Manual ▷ View online

1.2. Caution for AC Mains Lead
1.3. Before repair and adjustment
Disconnect AC power, discharge Power Capacitors C5101, C5104, C5171, C5172, C5920, C5940 and C5950 through a 10
Ω, 5W
5
SA-AK350E / SA-AK350EB / SA-AK350EG
resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 220-240V, 50 Hz in NO SIGNAL mode (volume min at CD mode) should be ~ 350mA.
1.4. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
     ·    No sound is heard when the power is turned on.
     ·    Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
 1. Turn off the power.
 2. Determine the cause of the problem and correct it.
 3. Turn on the power once again after one minute.
Note :
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
1.5. Safety Part Information
Safety Parts List:
There are special components used in this equipment which are important for safety.
These parts are marked by
in the Schematic Diagrams & Replacement Parts List. It is essential that these critical parts should
be replaced with manufacturer’s specified parts to prevent shock, fire or other hazards. Do not modify the original design without
permission of manufacturer.
Table 1
Reference No.
Part No.
Part name & Description
Remarks
L5601
G0B9R5K00001
CHOKE COIL
L5602
G0B9R5K00001
CHOKE COIL
L5603
G0B9R5K00001
CHOKE COIL
L5604
G0B9R5K00001
CHOKE COIL
L5950
ELF15N035AN
LINE FILTER
T5950
G4CYAYY00136
MAIN TRANSFORMER
T5951
G4C2AAJ00005
SUB TRANSFORMER
Z5950
ERZV10V511CS
ZENER
RL5950
K6B1AEA00015
POWER RELAY
F1
K5D202BLA013
FUSE
FP5920
K5G702A00009
FUSE PROTECTOR
FP5940
K5G702Z00004
FUSE PROTECTOR
FP5950
K5G402A00025
FUSE PROTECTOR
JK5950
K2AA2B000011
JK AC INLET
A2
K2CQ2CA00006
AC CORD
EG/ E
A2
K2CT3CA00004
AC CORD
EB
C5920
ECA1HM102E
1000 50V
360
RAE0165A-V
TRAVERSE UNIT
2 Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by electricity. Such components commonly are called
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor “chip” components. The following techniques should be used to help reduce the incidence of component damage
caused by electro static discharge (ESD).
 1. Immediately before handling any semiconductor component or semiconductor-equiped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
 2. After removing an electrical assembly equiped with ES devices, place the assembly on a conductive surface such as aluminium
foil, to prevent electrostatic charge build up or exposure of the assembly.
6
SA-AK350E / SA-AK350EB / SA-AK350EG
 3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
 4. Use only an anti-static solder remover device. Some solder removal devices not classified as “anti-static (ESD protected)” can
generate electrical charge to damage ES devices.
 5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
 6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminium foil or
comparable conductive material).
 7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
Caution
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
 8. Minimize body motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the brushing
together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient to
damage an ES device).
7
SA-AK350E / SA-AK350EB / SA-AK350EG
3 Handling Precautions For Traverse Deck
The laser diode in the traverse deck (optical pickup) may break down due to potential difference caused by the static electricity of
clothes or our human body.
So, be careful of electrostatic breakdown during repair of the traverse deck (optical pickup).
     ·    Way of handling the traverse deck (optical pickup)
 1. Do not subject the traverse deck (optical pickup) to static electricity as it is extremely sensitive to electrical shock.
 2. To prevent the breakdown of the laser diode, an antistatic shorting pin is inserted into the flexible board (FFC board).
 3. Do not to apply excessive stress to the flexible board (FFC board). When removing or connecting the short pin, finish the job
in as short time as possible.
 4. Do not turn the variable resistor for laser power adjustment. (It is pre-adjusted during production time)
Grounding for electrostatic breakdown prevention
 1. Human body grounding
Use the anti-static wrist strap to discharge the static electricity from your body.
 2. Work table grounding
Put a conductive material (sheet) or steel sheet on the area where the traverse deck (optical pickup) is place, and ground the
sheet.
Caution :
The static electricity of your clothes will not be grounded through the wrist strap. So, take care not to let your clothes touch the
traverse deck (optical pickup).
Caution when replacing the Traverse Deck
The traverse deck has a short point shorted with solder to protect the laser diode against electrostatics breakdown. Be sure to