Panasonic RR-US550PP / RR-US550E Service Manual ▷ View online

7
4 Specifications
Power
Batteries
DC 3.0 V (2 AAA LR03 batteries)
Audio
Sampling Frequency 
(Stereo/Monaural) 
XP: 44.1 kHz
LP: 16 kHz
SLP: 8 kHz
Recording Format
MP3
Playable Bit Rate (MUSIC 
folder)
8 kbps to 320 kbps
Playable Sampling 
Frequency (MUSIC folder)
8 kHz to 48 kHz
Frequency Response 
(-10 dB, Rec-Play, 
Monaural)
XP: 180 Hz to 15,100 Hz
LP: 180 Hz to 6,700 Hz
SLP: 180 Hz to 2,900 Hz
Built-in Microphone S/N 
Ratio
40.5 dB (XP) Filter (JIS A)
USB
USB2.0 (Hi-Speed)
Audio Output Earphone
ø 3.5 mm (1/8”), 16 
Ω, Max: 3 mW
Speaker 
output
ø 20 mm (25/32”), 8 
Ω, Max: 330 mW
Audio Input
External 
Microphone
ø 3.5 mm (1/8”),
0.80 mV plug in power
Built-in Memory
512 MB*
1
Operating Temperature
0
°C to 40°C (32°F to 104°F)
Operating Humidity
20% to 80% (non-condensing)
*
1  
MB means one million bytes. Usable capacity will be less.
Battery life (may be less depending on the operating conditions.)
Battery (AAA 
LR03)
Recording mode
Rec*
3
Play*
4
Alkaline 
battery*
2
XP
approx. 32 h.
approx. 35 h.
LP
approx. 42 h.
approx. 35 h.
SLP
approx. 45 h.
approx. 35 h.
*
2  
Using Panasonic Alkaline battery.
*
3  
When zoom microphone is off.
*
4  
When audio is output from speaker (Volume: 13, EQ: off, playback 
speed control: x 1).
Standard recordable time
Recording mode
Time
Bit rate
XP
17 h, 50 min.
64 kbps
LP
35 h, 40 min.
32 kbps
SLP
142 h, 50 min.
8 kbps
Max. Dimensions (WxHxD)
40.4 mm x 110.6 mm x 16.8 mm
(1-19/32” x 4-11/32” x 21/32”)
Cabinet Dimensions 
(WxHxD)
39 mm x 110.3 mm x 15.1 mm
(1-17/32” x 4-11/32” x 19/32”)
Mass (Weight)
Approx. 65 g (2.29 oz.) with battery
Approx. 43 g (1.51 oz.) without battery
Specifications are subject to change without notice.
8
5 Location of Controls and Components
5.1.
Components of IC Recorder
9
5.2.
Basic Operation
10
6 Self-diagnostic/Doctor Mode
6.1.
Service Functions
6.1.1.
Test Mode
Purpose: To enter into Test Mode for checking and inspection of unit.
Procedures:
1. Set the recording position switch to “MANUAL” at the power off.
(Setting to “MANUAL” after turning on the power is OK.)
2. Slide [OPR/HOLD] switch to “OPR” side to turn on the power.
3. Set to “HOLD” mode by pushing [OPR/HOLD] button.
4. Input the below keys while displaying the “HOLD”.
[MENU] --> [ERASE] --> [
]  --> [VOL-]
Note : Input of these keys are done within two seconds while displaying “HOLD”.
5. All segments of LCD will Light up & the unit will enter into the Operation Check Mode. During the Operation Check Mode, the
Recording LED will be blinking.
6. To cancel Test Mode, power off the unit by removing batteries.
6.1.2.
USB Serial Number (ID) Confirmation Function
Purpose: To check USB Serial Number (ID) which is written in the NAND flash memory at the final process is confirmed in this
mode.
Procedures:
1. Enter into Test Mode, check all segments of LCD light up.
2. Press and hold [
] for 10 seconds and the USB serial number which is written in NAND flash memory is displayed.
6.1.3.
Reset Function
Purpose:
• To reset to factory default setting.
• Only USB Serial Number (ID) is not initialized, and NAND flash memory is not formatted logically in this mode.
Procedures:
1. Enter into Test Mode, check all segments of LCD light up.
2. Set the Recording position switch to “WIDE”.
Page of 62
Display

Click on the first or last page to see other RR-US550PP / RR-US550E service manuals if exist.