Panasonic WH-SXC09H3E5 / WH-SXC12H6E5 / WH-UX09HE5 / WH-UX12HE5 Service Manual ▷ View online
12
Item
Unit
Indoor Unit
Performance Test Condition
EN 14511
Outdoor Ambient
°C
Cooling: 16 ~ 43
Heating: -28 ~ 25
Operation Range
Water Outlet
°C
Cooling: 5 ~ 20
Heating: 20 ~ 55 (Below Ambient -15°C)
20 ~ 60 (Below Ambient -10°C)
Internal Pressure Differential
kPa
Cooling: 36
Heating: 52
Heating: 52
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
dB (A)
Cooling: 33
Heating: 33
—
Noise Level
Power Level dB
Cooling: 46
Heating: 46
—
Height
mm (inch)
892 (35-1/8)
Width
mm (inch)
500 (19-11/16)
Dimension
Depth
mm (inch)
340 (13-13/32)
Net Weight
kg (lbs)
43 (95)
Liquid
mm (inch)
9.52 (3/8)
Refrigerant Pipe Diameter
Gas
mm (inch)
15.88 (5/8)
Inlet
mm (inch)
28 (1-3/32)
Water Pipe Diameter
Outlet
mm (inch)
28 (1-3/32)
Water Drain Hose Inner Diameter
mm (inch)
15 (19/32)
Motor Type
DC Motor
No. of Speed
7 (Software Selection)
Pump
Input Power
W
92
Type
Brazed
Plate
No. of Plates
36
Size (W × H × L)
mm
65 × 119 × 376
Hot Water Coil
Water Flow Rate
l/min (m
3
/h)
Cooling: 28.7 (1.7)
Heating: 34.4 (2.1)
Heating: 34.4 (2.1)
Pressure Relief Valve Water Circuit
kPa
Open: 300, Close: 266 and below
Flow Switch
Electronic Sensor
Protection Device
A
Residual Current Circuit Breaker (40)
Volume I
10
Expansion Vessel
MWP bar
3
Capacity of Integrated Electric Heater
kW
6.00
Note:
Cooling capacities are based on outdoor air temperature of 35°C Dry Bulb with controlled indoor water inlet
temperature of 12°C and water outlet temperature of 7°C.
Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb
(42.8°F Wet Bulb) with controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C.
Specification are subjected to change without prior notice for further improvement.
Flow rate indicated are based on nominal capacity adjustment of leaving water temperature (LWT) 35°C and
Flow rate indicated are based on nominal capacity adjustment of leaving water temperature (LWT) 35°C and
∆
T
= 5°C.
13
3. Features
Inverter Technology
- Energy saving
High Efficiency
Environment Protection
- Non-ozone depletion substances refrigerant (R410A)
Long Installation Piping
- Long piping up to 30 meter with height difference 20 meter
- Flexible 4-way piping for outdoor unit
Easy to use control panel
- Auto mode
- Holiday mode
- Dry concrete function
- Weekly timer setting
A-class energy efficiency pump
- Water pump speed can be set by selection at control panel
Improved deice cycle
Protection Feature
- Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
Serviceability Feature
- Breakdown Self Diagnosis function
- System Status Check Buttons for servicing purpose
- System Pumpdown Button for servicing purpose
- Front maintenance design for outdoor unit
14
4. Location of Controls and Components
4.1 Indoor
Unit
4.1.1 Location of Control
Buttons / Indicator
Water pressure gauge
• Do not press or hit the glass cover using hard
and sharp objects. Failure to do so may cause
damage to the unit.
• Ensure that the water pressure is between 0.05
and 0.3 MPa (0.1 MPa = 1 bar).
• In case the water pressure is out of the above
range, consult an authorised dealer.
1
Quick Menu button
(For more details, refer to the separate
Quick Menu Guide.)
2 Back button
Returns to the previous screen
3 LCD Display
4 Main Menu button
For function setup
5 ON/OFF button
Starts/Stops operation
6
Operation indicator
Illuminates during operation, blinks during
alarm.
Press centre
No glove
No pen
2
1
4
5
6
3
Cross key buttons
Selects an item.
Enter button
Fixes the selected content.
Up
Down
t
h
g
i
R
tf
e
L
0.2
0.4
0.3
0.1
MPa
bar
2
3
1
4
23
1
44
40
10:34am, Mon
18
˚
c
˚
c
˚
c
˚
c
2
15
Display
1 Mode selection
AUTO
• Depending on the preset outdoor
temperature, the system selects
HEAT or *
1
COOL operation mode.
Auto Heat
Auto Cool
*
1,
*
2
COOL
• The fan coil unit is either turned
ON or OFF.
• The outdoor unit provides cooling
to the system.
AUTO
+ TANK
• Depending on the preset outdoor
temperature, the system selects
HEAT + TANK or *
1
COOL + TANK
operation mode.
Auto Heat
Auto Cool
*
1,
*
2
COOL
+ TANK
• The outdoor unit provides cooling
to the system.
• The system controls the booster
heater in the water tank.
HEAT
• The panel/floor HEAT operation is
either turned ON or OFF.
• The outdoor unit provides heat to
the system.
TANK
• The water tank is either turned
ON or OFF.
• The outdoor unit provides heat to
the water tank.
HEAT
+ TANK
• The outdoor unit provides heat to
the water tank and the system.
• This mode can be selected only
when the water tank is installed.
* The direction icons point to the currently
active mode.
• Room operation / Tank operation.
• Deice operation.
2 Operation icons
The status of operation is displayed.
Icon will not display (under operation OFF screen) whenever operation is OFF except weekly timer.
Holiday operation status
Weekly Timer operation status
Quiet operation status
Zone:Room Thermostat
→Internal sensor status
Powerful operation status
Demand Control or
SG ready or SHP status
Room Heater status
Tank Heater status
Solar status
Bivalent status
(Boiler)
*1 The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*2 Only displayed when COOL mode is unlocked (This means when COOL mode is available).
*2 Only displayed when COOL mode is unlocked (This means when COOL mode is available).
3 Temperature of each zone
4 Time and day
5 Water Tank temperature
6 Outdoor temperature
7 Sensor type/Set temperature type icons
Water Temperature
→Compensation curve
Water Temperature
→Direct
Pool only
Room Thermostat
→External
Room Thermostat
→Internal
2
4
1
5
6
7
23
1
44
40
10:34am, Mon
18
˚
c
˚
c
˚
c
˚
c
2
3