3
1. Safety Precautions
Read the following “SAFETY PRECAUTIONS” carefully before installation of (Mono bloc) Air-to-Water Heatpump
system (hereafter referred to as “Mono bloc unit”).
Electrical works and water installation works must be done by licensed electrician and licensed water system
installer respectively. Be sure to use the correct rating and main circuit for the model to be installed.
The caution items stated here must be followed because these important contents are related to safety. The
meaning of each indication used is as below. Incorrect installation due to ignorance or negligence of the
instructions will cause harm or damage, and the seriousness is classified by the following indications.
instructions will cause harm or damage, and the seriousness is classified by the following indications.
WARNING
This indication shows the possibility of causing death or serious injury.
CAUTION
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classified by the symbols:
Symbol with white background denotes item that is PROHIBITED from doing.
Symbol with dark background denotes item that must be carried out.
Carry out test run to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice and
information.
information.
WARNING
1.
Do not install Mono bloc unit near handrail of veranda. When installing Mono bloc unit at veranda of high rise building, child may climb
up to Mono bloc unit and cross over the handrail and causing accident.
up to Mono bloc unit and cross over the handrail and causing accident.
2.
Do not use unspecified cord, modified cord, join cord or extension cord for power supply cord. Do not share the single outlet with other
electrical appliances.
Poor contact, poor insulation or over current will cause electrical shock or fire.
electrical appliances.
Poor contact, poor insulation or over current will cause electrical shock or fire.
3. Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen.
4. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.
5. Do not sit or step on the unit, you may fall down accidentally.
6. Keep plastic bag (packaging material) away from small children, it may cause suffocation.
7. Do not use pipe wrench to install refrigerant pipe. It might deform the piping and cause the unit to malfunction.
8. Do not purchase unauthorized electrical parts for installation, service, maintenance and etc.. They might cause electrical shock or fire.
9. This unit is a multi supply appliances. All circuits must be disconnected before accessing to the unit terminals.
10.
Do not modify the wiring of Mono bloc unit for installation of other components (i.e. heater, etc.). Overloaded wiring or wire connection
points may cause electrical shock or fire.
points may cause electrical shock or fire.
11. Do not add or replace refrigerant other than specified type. It may cause product damage, burst and injury etc.
12.
For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and
single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or
fire.
single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or
fire.
13.
For water circuit installation work, follow to relevant European and national regulations (including EN61770) and local plumbing and
building regulation codes.
building regulation codes.
14.
Must engage an authorized dealer or specialist for installation. If installation is defective, it will cause water leakage, electrical shock or
fire.
fire.
15. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
16.
Only use the supplied or specified installation parts. Else, it may causes Mono bloc unit vibrate, fall, water leakage, electrical shock or
fire.
fire.
17.
Install at a flat, strong and firm location which is able to withstand the Mono bloc unit’s weight. If the location is slanting, or strength is
not enough the set will fall and cause injury.
not enough the set will fall and cause injury.
4
WARNING
18.
This equipment is strongly recommended to be installed with Residual Current Device (RCD) on-site according to the respective
national wiring rules or country-specific safety measures in terms of residual current.
national wiring rules or country-specific safety measures in terms of residual current.
19.
The unit is only for use in a closed water system. Utilization in an open water system may lead to excessive corrosion of the water
piping and risk of incubating bacteria colonies, particularly Legionella, in water.
piping and risk of incubating bacteria colonies, particularly Legionella, in water.
20. If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice and information.
21. Select a location where in case of water leakage, the leakage will not cause damage to other properties.
22.
When installing electrical equipment at wooden building of metal lath or wire lath, in accordance with electrical facility standard, no
electrical contact between equipment and building is allowed. Insulator must be installed in between.
electrical contact between equipment and building is allowed. Insulator must be installed in between.
23.
This installation may be subjected to building regulation approval applicable to respective country that may require to notify the local
authority before installation.
authority before installation.
24.
Any work carried out on the Mono bloc unit after removing the front panel which is secured by screws, must be carried out under the
supervision of authorized dealer and licensed installation contractor.
supervision of authorized dealer and licensed installation contractor.
25.
This unit must be properly earthed, the electrical earth must not be connected to a gas pipe, water pipe, the earth of a lightening rod or
a telephone. Otherwise there is a danger of electrical shock in the event of an insulation breakdown or electrical earth fault in the
Mono bloc unit.
a telephone. Otherwise there is a danger of electrical shock in the event of an insulation breakdown or electrical earth fault in the
Mono bloc unit.
CAUTION
1.
Do not install the Mono bloc unit in areas where there is a risk of flammable gas leakage. There is a risk of fire if flammable gas
accumulates near or around the Mono bloc unit.
accumulates near or around the Mono bloc unit.
2.
Do not release refrigerant during piping work for installation, re-installation and during repairing a refrigeration parts. Take care of the
liquid refrigerant, it may cause frostbite.
liquid refrigerant, it may cause frostbite.
3.
Make sure the power supply cord does not contact with hot part (i.e. water piping). High temperature may cause insulator of power
supply cord damage hence electrical shock or fire.
supply cord damage hence electrical shock or fire.
4. Do not touch the sharp aluminium fin, sharp parts may cause injury.
5.
Do not apply excessive force to water pipes that may damage the pipes. If water leakage occurs, it will cause flooding and damage to
other properties.
other properties.
6.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water leakage may happen and may
cause damage to properties of the user.
cause damage to properties of the user.
7.
The piping installation work must be flushed before the Mono bloc unit is connected to remove contaminants. Contaminants may
damage the Mono bloc unit components.
damage the Mono bloc unit components.
8. Select an installation location where it is accessible for maintenance.
9.
Power supply connection to the Mono bloc unit.
Power supply point should be in easily accessible place for power disconnection in case of emergency.
Must follow local national wiring standard, regulation and this installation instruction.
Strongly recommended to make permanent connection to a circuit breaker with a minimum 3.0 mm contact gap.
-
-
Power supply 1: Use approved 20A 4-poles circuit breaker.
-
Power supply 2: Use approved 20A 4-poles circuit breaker.
10. Ensure the correct polarity is maintained throughout all wiring. Otherwise, it will cause electrical shock or fire.
11.
After installation, the installer is obliged to verify correct operation of the Mono bloc unit. Check the connection point for water leakage
during test run. If leakage occurs, it will cause damage to other properties.
during test run. If leakage occurs, it will cause damage to other properties.
12.
Installation work.
Four or more people are required to carry out the installation work. The weight of Mono bloc unit might cause injury if carried by less
than four people.
Four or more people are required to carry out the installation work. The weight of Mono bloc unit might cause injury if carried by less
than four people.
5
2. Specifications
Item
Unit
Refrigerant System
Performance Test Condition
EN14511
Cooling Condition (Ambient/Water)
A35W7
-
Cooling Capacity
kW
12.20
-
BTU/h
41600
-
kcal/h
10490
-
EER
W/W
2.56
-
kcal/hW
2.20
-
Heating Condition (Ambient/Water)
A7W35
A2W35
Heating Capacity
kW
16.00
16.00
BTU/h
54600
54600
kcal/h
13760
13760
COP
W/W
4.28
3.10
kcal/hW
3.68
2.67
Air Flow
m
3
/min (ft
3
/min)
Cooling: 109.4 (3860)
Heating: 76.0 (2680)
Refrigeration Control Device
Expansion Valve
Refrigeration Oil
cm
3
FV50S (1600)
Refrigerant (R410A)
kg (oz)
2.35 (82.9)
Compressor
Type
Hermetic Motor (Rotary)
Motor Type
Brushless (4-poles)
Rated Output
kW
4.76
Fan
Type
Propeller Fan
Material
PP
Motor Type
DC (8-poles)
Input Power
W
-
Output Power
W
60
Fan Speed
rpm
Cooling: 680 (Top Fan) 720 (Bottom Fan)
Heating: 580 (Top Fan) 620 (Bottom Fan)
Heating: 580 (Top Fan) 620 (Bottom Fan)
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Fin Type
Corrugated Fin
Row × Stage × FPI
2 × 51 × 19
Size (W × H × L)
mm
898.8 × 1295.4 × 44
Item
Unit
Mono bloc Unit
Dimension
Height
mm (inch)
1410 (55-1/2)
Width
mm (inch)
1283 (50-1/2)
Depth
mm (inch)
320 (12-19/32)
Net Weight
kg (lbs)
168 (370)
Noise Level
dB-A
Cooling: 54
Heating: 53
Heating: 53
Cooling: -
Heating: -
Heating: -
Power Level dB
Cooling: 74
Heating: 70
Heating: 70
Cooling: -
Heating: -
Heating: -
Power Source (Phase, Voltage, Cycle)
ø
Three
V
400
Hz
50
6
Item
Unit
Mono bloc Unit
Input Power
kW
Cooling: 4.76
Heating: 3.74
Heating: 3.74
Cooling: -
Heating: 5.16
Maximum Input Power For Mono bloc Unit
kW
10.27
Power Supply 1: Phase (ø) / Max. Current (A) / Max. Input Power (W)
Three / 15.5 / 10.27k
Power Supply 2: Phase (ø) / Max. Current (A) / Max. Input Power (W)
Single / 13.0 / 9.00k
Power Supply 3: Phase (ø) / Max. Current (A) / Max. Input Power (W)
- / - / -
Starting Current
A
7.2
Running Current
A
Cooling: 7.2
Heating: 5.7
Heating: 5.7
Cooling: -
Heating: 7.8
Maximum Current For Mono bloc Unit
A
15.5
Power Factor
%
Cooling: 96
Heating: 95
Heating: 95
Cooling: -
Heating: 96
Power factor means total figure of compressor and outdoor fan motor.
Power Cord
Number of core
-
Length
m (ft)
-
Thermostat
Electronic Control
Protection Device
Electronic Control
Item
Unit
Water System
Performance Test Condition
EN14511
Operation Range
Outdoor Ambient
°C
Cooling: 16 ~ 43
Heating: -20 ~ 35
Water Outlet
°C
Cooling: 5 ~ 20
Heating: 25 ~ 55
Internal Pressure Differential
kPa
Cooling: 40.0
Heating: 64.0
Heating: 64.0
Water Pipe Diameter
Inlet
mm (inch)
30 (1-3/16)
Outlet
mm (inch)
30 (1-3/16)
Water Drain Hose Inner Diameter
mm (inch)
15.00 (19/32)
Pump
Motor Type
DC Motor
No. of Speed
7 (software selection)
Input Power
W
109
Hot Water Coil
Type
Brazed Plate
No. of Plates
52
Size (H × W × L)
mm
93 × 120 × 376
Water Flow Rate
l/min (m
3
/h)
Cooling: 35.0 (2.1)
Heating: 45.9 (2.8)
Heating: 45.9 (2.8)
Pressure Relief Valve Water Circuit
kPa
Open: 300, Close: 265 and below
Flow Switch
Magnetic Lead Switch
Protection Device
A
Residual Current Circuit Breaker (25)
Expansion Vessel
Volume
I
10
MWP
bar
3
Capacity of Integrated Electric Heater
kW
9.00
Note:
1.
Cooling capacities are based on outdoor air temperature of 35°C Dry Bulb with controlled water inlet temperature of 12°C and water outlet
temperature of 7°C.
temperature of 7°C.
2.
Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) with controlled
water inlet temperature of 30°C and water outlet temperature of 35°C.
water inlet temperature of 30°C and water outlet temperature of 35°C.
3.
Specifications are subjected to change without prior notice for further improvement.