16.5.31  Outdoor Discharge Pipe Temperature Sensor Abnormality (F40) 
 
Malfunction Decision Conditions: 
During startup and operation of cooling and heating, the temperatures detected by the outdoor discharge pipe 
temperature sensor are used to determine sensor error. 
 
Malfunction Caused: 
1.  Faulty connector connection. 
2.  Faulty sensor. 
3.  Faulty outdoor unit PCB (main). 
 
Abnormality Judgment: 
Continue for 5 seconds. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
124 
16.5.32  Power Factor Correction (PFC) Abnormality (F41) 
 
Malfunction Decision Conditions: 
During operation of cooling and heating, when the PFC protection circuitry in the outdoor unit PCB (main) senses 
abnormal high DC voltage level. 
 
Malfunction Caused: 
1.  Power supply surge. 
2.  Compressor windings not uniform. 
3.  Faulty outdoor unit PCB (main). 
 
Abnormality Judgment: 
Continue 4 times in 10 minutes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
125 
16.5.33  Outdoor Pipe Temperature Sensor Abnormality (F42) 
 
Malfunction Decision Conditions: 
During startup and operation of cooling and heating, the temperatures detected by the outdoor pipe temperature 
sensor are used to determine sensor error. 
 
Malfunction Caused: 
1.  Faulty connector connection. 
2.  Faulty sensor. 
3.  Faulty outdoor unit PCB (main). 
 
Abnormality Judgment: 
Continue for 5 seconds. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
126 
16.5.34  Outdoor Defrost Temperature Sensor Abnormality (F43) 
 
Malfunction Decision Conditions: 
During startup and operation of cooling and heating, the temperatures detected by the outdoor defrost 
temperature sensor are used to determine sensor error. 
 
Malfunction Caused: 
1.  Faulty connector connection. 
2.  Faulty sensor. 
3.  Faulty outdoor unit PCB (main). 
 
Abnormality Judgment: 
Continue for 5 seconds. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 