DOWNLOAD Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Service Manual ↓ Size: 129.09 MB | Pages: 127 in PDF or view online for FREE

Model
U-50PE2E5A U-100PE1E8A U-100PEY1E8 U-125PE1E8A U-125PEY1E8 U-140PE1E8A U-140PEY1E8 S-100PU2E5B S-125PU2E5B S-140PU2E5B S-71PU2E5B S-100PF1E5B S-125PF1E5B S-140PF1E5B S-71PF1E5B
Pages
127
Size
129.09 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
u-50pe2e5a-u-100pe1e8a-u-100pey1e8-u-125pe1e8a-u-1.pdf
Date

Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Service Manual ▷ View online

ix
Combination of Indoor and Outdoor Units
PE1
S-140PU2E5B
U-140PE1E8A
S-45PU2E5B x3
U-125PE1E8A
S-60PU2E5B x2
U-125PE1E8A
S-36PU2E5B x4
U-125PE1E8A
S-36PU2E5B x2
U-71PE1E8A
S-36PU2E5B x3
U-100PE1E8A
S-50PU2E5B x2
U-100PE1E8A
S-50PU2E5B x3
U-140PE1E8A
S-71PU2E5B
U-71PE1E8A
S-71PU2E5B x2
U-140PE1E8A
S-100PU2E5B
U-100PE1E8A
S-125PU2E5B
U-125PE1E8A
3-phase
S-140PF1E5B
U-140PE1E8A
S-45PF1E5B x3
U-125PE1E8A
S-60PF1E5B x2
U-125PE1E8A
S-36PF1E5B x4
U-125PE1E8A
S-36PF1E5B x2
U-71PE1E8A
S-36PF1E5B x3
U-100PE1E8A
S-50PF1E5B x2
U-100PE1E8A
S-50PF1E5B x3
U-140PE1E8A
S-71PF1E5B
U-71PE1E8A
S-71PF1E5B x2
U-140PE1E8A
S-100PF1E5B
U-100PE1E8A
S-125PF1E5B
U-125PE1E8A
S-140PN1E5B
U-140PE1E8A
S-45PN1E5B x3
U-125PE1E8A
S-60PN1E5B x2
U-125PE1E8A
S-36PN1E5B x4
U-125PE1E8A
S-36PN1E5B x2
U-71PE1E8A
S-36PN1E5B x3
U-100PE1E8A
S-50PN1E5B x2
U-100PE1E8A
S-50PN1E5B x3
U-140PE1E8A
S-71PN1E5B
U-71PE1E8A
S-71PN1E5B x2
U-140PE1E8A
S-100PN1E5B
U-100PE1E8A
S-125PN1E5B
U-125PE1E8A
S-45PK2E5B x3
U-125PE1E8A
S-60PK2E5B x2
U-125PE1E8A
S-36PK2E5B x4
U-125PE1E8A
S-36PK2E5B x2
U-71PE1E8A
S-36PK2E5B x3
U-100PE1E8A
S-50PK2E5B x2
U-100PE1E8A
S-50PK2E5B x3
U-140PE1E8A
S-71PK2E5B
U-71PE1E8A
S-71PK2E5B x2
U-140PE1E8A
S-140PT2E5B
U-140PE1E8A
S-45PT2E5B x3
U-125PE1E8A
S-36PT2E5B x4
U-125PE1E8A
S-36PT2E5B x2
U-71PE1E8A
S-36PT2E5B x3
U-100PE1E8A
S-60PT2E5B x2
U-125PE1E8A
S-50PT2E5B x2
U-100PE1E8A
S-50PT2E5B x3
U-140PE1E8A
S-71PT2E5B
U-71PE1E8A
S-71PT2E5B x2
U-140PE1E8A
S-100PT2E5B
U-100PE1E8A
S-125PT2E5B
U-125PE1E8A
S-45PY2E5B x3
U-125PE1E8A
S-36PY2E5B x4
U-125PE1E8A
S-36PY2E5B x2
U-71PE1E8A
S-36PY2E5B x3
U-100PE1E8A
S-50PY2E5B x2
U-100PE1E8A
S-50PY2E5B x3
U-140PE1E8A
S-100PK2E5B
U-100PE1E8A
U2
36
45
50
60
71
100
125
140
T2
F1
N1
Y2
K2
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   9
2019/09/24   16:21:17
x
Combination of Indoor and Outdoor Units
Single-phase
U2
PEY1
50
60
71
100
125
140
S-60PU2E5B x2
U-125PEY1E5
S-50PU2E5B x2
U-100PEY1E5
S-100PU2E5B
U-100PEY1E5
S-125PU2E5B
U-125PEY1E5
S-60PU2E5B x2
U-125PEY1E8
S-50PU2E5B x2
U-100PEY1E8
S-71PU2E5B x2
U-140PEY1E8
S-100PU2E5B
U-100PEY1E8
S-125PU2E5B
U-125PEY1E8
S-140PU2E5B
U-140PEY1E8
S-60PF1E5B x2
U-125PEY1E8
S-50PF1E5B x2
U-100PEY1E8
S-71PF1E5B x2
U-140PEY1E8
S-100PF1E5B
U-100PEY1E8
S-125PF1E5B
U-125PEY1E8
S-140PF1E5B
U-140PEY1E8
S-60PN1E5B x2
U-125PEY1E8
S-50PN1E5B x2
U-100PEY1E8
S-71PN1E5B x2
U-140PEY1E8
S-100PN1E5B
U-100PEY1E8
S-125PN1E5B
U-125PEY1E8
S-140PN1E5B
U-140PEY1E8
S-50PY2E5B x2
U-100PEY1E8
S-60PT2E5B x2
U-125PEY1E8
S-50PT2E5B x2
U-100PEY1E8
S-71PT2E5B x2
U-140PEY1E8
S-100PK2E5B
U-100PEY1E8
S-125PT2E5B
U-125PEY1E8
S-140PT2E5B
U-140PEY1E8
S-60PK2E5B x2
U-125PEY1E8
S-50PK2E5B x2
U-100PEY1E8
S-71PK2E5B x2
U-140PEY1E8
3-phase
F1
S-60PF1E5B
U-60PEY2E5
S-60PF1E5B x2
U-125PEY1E5
S-50PF1E5B x2
U-100PEY1E5
S-71PF1E5B
U-71PEY2E5
S-100PF1E5B
U-100PEY1E5
S-125PF1E5B
U-125PEY1E5
N1
S-60PN1E5B
U-60PEY2E5
S-60PN1E5B x2
U-125PEY1E5
S-50PN1E5B x2
U-100PEY1E5
S-71PN1E5B
U-71PEY2E5
S-100PN1E5B
U-100PEY1E5
S-125PN1E5B
U-125PEY1E5
Y2
S-50PY2E5B x2
U-100PEY1E5
T2
S-60PT2E5B
U-60PEY2E5
S-60PT2E5B x2
U-125PEY1E5
S-50PT2E5B x2
U-100PEY1E5
S-71PT2E5B
U-71PEY2E5
S-60PU2E5B
U-60PEY2E5
S-71PU2E5B
U-71PEY2E5
S-100PK2E5B
U-100PEY1E5
S-125PT2E5B
U-125PEY1E5
K2
S-60PK2E5B
U-60PEY2E5
S-60PK2E5B x2
U-125PEY1E5
S-50PK2E5B x2
U-100PEY1E5
S-71PK2E5B
U-71PEY2E5
S-100PT2E5B
U-100PEY1E5
S-100PT2E5B
U-100PEY1E8
PEY2
PEY1
U2
50
60
71
100
125
140
F1
N1
Y2
T2
K2
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   10
2019/09/24   16:21:17
xi
Section 1. SPECIFICATIONS............................................................................................
1-1.  Unit Specifications
1-1-1-2
1-2.  Dimensional Data
1-2-1
1-3.  Refrigerant Flow Diagram
1-3-1
1-4.  Operating Range
...........................................................................................................
 ................................................................................................................
 ...................................................................................................
.................................................................................................................1-4-1
1-5.  Capacity Correction Graph According to Temperature Condition ........................................1-5-1
1-6.  Noise Criterion Curves
1-6-1
1-7.  Indoor Fan Performance
1-7-1
1-8.  Airflow Distance Chart
1-8-1
1-9.  Fresh Air Intake
1-10.  Electrical Wiring
1-10-1
1-11.  Installation Instructions
1-11-1-1
1-13.  Capacity Table ..............................................................................................................
1.  Cooling Capacity Performance Data
2.  Heating Capacity Performance Data
.............................................................................
.............................................................................
1-13-1-1
1-15.  Information Table
1-14.  Product Fiche
...................................................................................................................1-15-1
...................................................................................................................1-14-1
1-12.  How to select AHU system ..............................................................................................1-12-1
1-13-1-1
1-13-2-1
1-11-1-1
........................................................................................................
......................................................................................................
........................................................................................................
1-9-1
....................................................................................................................
...............................................................................................................
 .................................................................................................
 Outdoor Unit
 Indoor Unit
..................................................................................................................
.....................................................................................................................1-11-3-1
——  CONTENTS  ——
 
60B6LQJOHBḢᕞ᪉ྥ7' 60LQGE
1-1-1-1
2-1. Preparing for Test Run
 
..........................................................................................................  2-2
 2-2. Caution
 
..................................................................................................................................  2-3
 2-3. Test Run Procedure
 
..............................................................................................................  2-3
2-14. PRECAUTIONS REGARDING TEST RUN
 
......................................................................
 2-15. CHECKS AFTER INSTALLATION HAVE COMPLETED
 
..................................................  2-15
 2-16. REGARDING DELIVERY TO THE CUSTOMER
 
..............................................................  2-15
2-4. Items to Check Before the Test Run  .....................................................................................  2-3
 2-5. Test Run Using the Remote Controller
 
.................................................................................  2-4
 2-6. Precautions
 
...........................................................................................................................  2-5
 2-7. Setting the outdoor unit system addresses ..........................................................................  2-6
2-8. Auto address setting using the remote controller
 
..................................................................  2-7
 2-9. Indicating (marking) the indoor and outdoor unit combination number
 
.................................  2-9
 2-10. Table of Self-Diagnostic Functions and Corrections
 
........................................................  2-10
2-11. Auto address setting from the outdoor unit
 
.......................................................................  2-13
 2-12. Test run using the indicator of the indoor unit (Type K2)
 
.................................................  2-13
 2-13. Caution for Pump Down
 
....................................................................................................  2-13
 2-14
Section 3. ELECTRICAL DATA
3-1.  Indoor Units (Electric Wiring Diagram)
3-2
3-2.  Outdoor Units (Electric Wiring Diagram)
.................................................................................
.............................................................................. 3-9
 .............................................................................................. 3-1
Section 2. TEST RUN ............................................................................................................. 2-1
U-36PE2E5A, U-50PE2E5A, U-60PE2E5A
U-60PEY2E5, U-71PEY2E5
U-71PE1E5A, U-100PE1E5A, U-125PE1E5A, U-140PE1E5A
U-100PEY1E5, U-125PEY1E5
U-71PE1E8A, U-100PE1E8A, U-125PE1E8A, U-140PE1E8A
U-100PEY1E8, U-125PEY1E8, U-140PEY1E8
60B6LQJOHBḢᕞ᪉ྥ7' 60LQGE
Section 6. OUTDOOR UNIT MAINTENANCE REMOTE CONTROLLER .............................
6-1.
6-2
6-2.
6-2
6-3
6-8
6-10
6-11
6-3.
6-4.
6-5.
6-6.
Overview ...............................................................................................................................
Functions ...............................................................................................................................
Normal Display Operations and Functions ............................................................................
Monitoring Operations: Display of Indoor Unit and Outdoor Unit Sensor Temperatures ......
Monitoring the Outdoor Unit Alarm History: Display of Outdoor Unit Alarm History ...........
Settings Modes: Setting the Outdoor Unit EEPROM ..........................................................
Section 7. REMOTE CONTROLLER FUNCTIONS SECTION ..............................................
7-1.
7-2
7-2.
7-4
7-3.
7-5
7-4.
7-7
7-5.
7-11
7-6.
7-13
7-17
7-7.
7-8.
Simple Settings Function .......................................................................................................
List of Simple Setting Items ...................................................................................................
Detailed Settings Function ....................................................................................................
List of Detailed Setting Items .................................................................................................
Simple Setting Items ...........................................................................................................
Detaild Setting Items ...........................................................................................................
Remote Controller Servicing Functions ...............................................................................
Test Run Function ...............................................................................................................7-19
6-1
7-1
4-11.  Parameter
4-13.  Outdoor Unit Control PCB
..........................................................................................................................
.................................................................................................
4-10
4-23
4-12.  Control Functions .............................................................................................................. 4-11
Section 5. TROUBLE DIAGNOSIS......................................................................................... 5-1
5-1.  Contents of Remote Controller Switch Alarm Display
5-2.  Outdoor Unit Control Panel LED Display
5-3.  PAC System Alarm Codes
5-7
5-4.  Inspection of Parts (Outdoor Unit)
5-78
5-5.  Symptom: Thermostat in OFF continues or cycles OFF & ON too frequently
5-2
5-79
5-6.  How to Clean Heat Exchanger
...........................................................
............................................................................... 5-6
.....................................................................................................
.......................................................................................
.....................
............................................................................................ 5-80
5-7.  How to Replace Fan Motor  ................................................................................................. 5-81
Section 4. CONTROL FUNCTIONS....................................................................................... 4-1
4-1.  Room Temperature Control
4-2.  Heating Standby ....................................................................................................................
4-3.  Automatic Fan Speed Control
4-4.  Drain Pump Control  ..............................................................................................................
4-5.  Automatic Heating/Cooling Control
4-6.  Automatic Flap Control  .........................................................................................................
4-7.  Filter Sign
4-8.  Fan Control during Dry Mode
4-9.  Ventilation Fan Output
...................................................................................................
...............................................................................................
.......................................................................................
..............................................................................................................................
................................................................................................
 ...........................................................................................................
4-2
4-4
4-5
4-6
4-7
4-8
4-8
4-9
4-9
4-10.  T10 Terminal ........................................................................................................................ 4-9
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   11
2019/09/24   16:21:18
xii
Section 1. SPECIFICATIONS............................................................................................
1-1.  Unit Specifications
1-1-1-2
1-2.  Dimensional Data
1-2-1
1-3.  Refrigerant Flow Diagram
1-3-1
1-4.  Operating Range
...........................................................................................................
 ................................................................................................................
 ...................................................................................................
.................................................................................................................1-4-1
1-5.  Capacity Correction Graph According to Temperature Condition ........................................1-5-1
1-6.  Noise Criterion Curves
1-6-1
1-7.  Indoor Fan Performance
1-7-1
1-8.  Airflow Distance Chart
1-8-1
1-9.  Fresh Air Intake
1-10.  Electrical Wiring
1-10-1
1-11.  Installation Instructions
1-11-1-1
1-13.  Capacity Table ..............................................................................................................
1.  Cooling Capacity Performance Data
2.  Heating Capacity Performance Data
.............................................................................
.............................................................................
1-13-1-1
1-15.  Information Table
1-14.  Product Fiche
...................................................................................................................1-15-1
...................................................................................................................1-14-1
1-12.  How to select AHU system ..............................................................................................1-12-1
1-13-1-1
1-13-2-1
1-11-1-1
........................................................................................................
......................................................................................................
........................................................................................................
1-9-1
....................................................................................................................
...............................................................................................................
 .................................................................................................
 Outdoor Unit
 Indoor Unit
..................................................................................................................
.....................................................................................................................1-11-3-1
——  CONTENTS  ——
 
60B6LQJOHBḢᕞ᪉ྥ7' 60LQGE
1-1-1-1
2-1. Preparing for Test Run
 
..........................................................................................................  2-2
 2-2. Caution
 
..................................................................................................................................  2-3
 2-3. Test Run Procedure
 
..............................................................................................................  2-3
2-14. PRECAUTIONS REGARDING TEST RUN
 
......................................................................
 2-15. CHECKS AFTER INSTALLATION HAVE COMPLETED
 
..................................................  2-15
 2-16. REGARDING DELIVERY TO THE CUSTOMER
 
..............................................................  2-15
2-4. Items to Check Before the Test Run  .....................................................................................  2-3
 2-5. Test Run Using the Remote Controller
 
.................................................................................  2-4
 2-6. Precautions
 
...........................................................................................................................  2-5
 2-7. Setting the outdoor unit system addresses ..........................................................................  2-6
2-8. Auto address setting using the remote controller
 
..................................................................  2-7
 2-9. Indicating (marking) the indoor and outdoor unit combination number
 
.................................  2-9
 2-10. Table of Self-Diagnostic Functions and Corrections
 
........................................................  2-10
2-11. Auto address setting from the outdoor unit
 
.......................................................................  2-13
 2-12. Test run using the indicator of the indoor unit (Type K2)
 
.................................................  2-13
 2-13. Caution for Pump Down
 
....................................................................................................  2-13
 2-14
Section 3. ELECTRICAL DATA
3-1.  Indoor Units (Electric Wiring Diagram)
3-2
3-2.  Outdoor Units (Electric Wiring Diagram)
.................................................................................
.............................................................................. 3-9
 .............................................................................................. 3-1
Section 2. TEST RUN ............................................................................................................. 2-1
U-36PE2E5A, U-50PE2E5A, U-60PE2E5A
U-60PEY2E5, U-71PEY2E5
U-71PE1E5A, U-100PE1E5A, U-125PE1E5A, U-140PE1E5A
U-100PEY1E5, U-125PEY1E5
U-71PE1E8A, U-100PE1E8A, U-125PE1E8A, U-140PE1E8A
U-100PEY1E8, U-125PEY1E8, U-140PEY1E8
60B6LQJOHBḢᕞ᪉ྥ7' 60LQGE
Section 6. OUTDOOR UNIT MAINTENANCE REMOTE CONTROLLER .............................
6-1.
6-2
6-2.
6-2
6-3
6-8
6-10
6-11
6-3.
6-4.
6-5.
6-6.
Overview ...............................................................................................................................
Functions ...............................................................................................................................
Normal Display Operations and Functions ............................................................................
Monitoring Operations: Display of Indoor Unit and Outdoor Unit Sensor Temperatures ......
Monitoring the Outdoor Unit Alarm History: Display of Outdoor Unit Alarm History ...........
Settings Modes: Setting the Outdoor Unit EEPROM ..........................................................
Section 7. REMOTE CONTROLLER FUNCTIONS SECTION ..............................................
7-1.
7-2
7-2.
7-4
7-3.
7-5
7-4.
7-7
7-5.
7-11
7-6.
7-13
7-17
7-7.
7-8.
Simple Settings Function .......................................................................................................
List of Simple Setting Items ...................................................................................................
Detailed Settings Function ....................................................................................................
List of Detailed Setting Items .................................................................................................
Simple Setting Items ...........................................................................................................
Detaild Setting Items ...........................................................................................................
Remote Controller Servicing Functions ...............................................................................
Test Run Function ...............................................................................................................7-19
6-1
7-1
4-11.  Parameter
4-13.  Outdoor Unit Control PCB
..........................................................................................................................
.................................................................................................
4-10
4-23
4-12.  Control Functions .............................................................................................................. 4-11
Section 5. TROUBLE DIAGNOSIS......................................................................................... 5-1
5-1.  Contents of Remote Controller Switch Alarm Display
5-2.  Outdoor Unit Control Panel LED Display
5-3.  PAC System Alarm Codes
5-7
5-4.  Inspection of Parts (Outdoor Unit)
5-78
5-5.  Symptom: Thermostat in OFF continues or cycles OFF & ON too frequently
5-2
5-79
5-6.  How to Clean Heat Exchanger
...........................................................
............................................................................... 5-6
.....................................................................................................
.......................................................................................
.....................
............................................................................................ 5-80
5-7.  How to Replace Fan Motor  ................................................................................................. 5-81
Section 4. CONTROL FUNCTIONS....................................................................................... 4-1
4-1.  Room Temperature Control
4-2.  Heating Standby ....................................................................................................................
4-3.  Automatic Fan Speed Control
4-4.  Drain Pump Control  ..............................................................................................................
4-5.  Automatic Heating/Cooling Control
4-6.  Automatic Flap Control  .........................................................................................................
4-7.  Filter Sign
4-8.  Fan Control during Dry Mode
4-9.  Ventilation Fan Output
...................................................................................................
...............................................................................................
.......................................................................................
..............................................................................................................................
................................................................................................
 ...........................................................................................................
4-2
4-4
4-5
4-6
4-7
4-8
4-8
4-9
4-9
4-10.  T10 Terminal ........................................................................................................................ 4-9
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   12
2019/09/24   16:21:18
Page of 127
Display

Click on the first or last page to see other U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B service manuals if exist.