Panasonic U-4LE1E5 / U-4LE1E8 / U-5LE1E5 / U-5LE1E8 / U-6LE1E5 / U-6LE1E8 (serv.man2) Service Manual ▷ View online
iv
Section 1: OUTLINE OF MINI VRF SYSTEM ...........................................................................
2-1
3-1
4-1
1-2
1-1
2-2
2-13
2-18
2-27
2-42
2-45
2-47
2-18
2-27
2-42
2-45
2-47
4-2
5-1
6-1
5-2
5-3
5-4
5-7
5-3
5-4
5-7
5-14
5-14
5-15
5-14
5-15
6-2
1-4
1. Line-up .................................................................................................................
2. MARKINGS FOR DIRECTIVE 97/23/EC (PED) ...................................................
2. MARKINGS FOR DIRECTIVE 97/23/EC (PED) ...................................................
Section 2: DESIGN OF MINI VRF SYSTEM ............................................................................
1. Model Selecting and Capacity Calculator ............................................................
2. System Design ..................................................................................................
3. Electrical Wiring .................................................................................................
2. System Design ..................................................................................................
3. Electrical Wiring .................................................................................................
5. HOW TO PROCESS TUBING ...........................................................................
6. AIR PURGING ...................................................................................................
7. Optional Parts ....................................................................................................
6. AIR PURGING ...................................................................................................
7. Optional Parts ....................................................................................................
4. Installation Instructions ......................................................................................
Section 3: Control of MINI VRF SYSTEM ...............................................................................
1. Main Operating Functions
2. Wireless Remote Controller
3. Timer Remote Controller (CZ-RTC2)
4. Simplified Remote Controller (CZ-RE2C2, CZ-RELC2)
5. System Controller (CZ-64ESMC2)
6. Schedule Time (CZ-ESWC2)
7. ON/OFF Controller (CZ-ANC2)
8. Intelligent Controller (CZ-256ESMC2)
9. Communication Adaptor (CZ-CFUNC2)
10. Remote Sensor (CZ-CSRC2)
11. LonWorks Interface (CZ-CLNC2)
12. Seri-Para I/O unit for outdoor unit (CZ-CAPDC2)
13. MINI Seri-para I/O Unit (CZ-CAPBC2)
14. Local Adaptor for ON/OFF Controller (CZ-CAPC2)
15. Web Interface (CZ-CWEBC2)
2. Wireless Remote Controller
3. Timer Remote Controller (CZ-RTC2)
4. Simplified Remote Controller (CZ-RE2C2, CZ-RELC2)
5. System Controller (CZ-64ESMC2)
6. Schedule Time (CZ-ESWC2)
7. ON/OFF Controller (CZ-ANC2)
8. Intelligent Controller (CZ-256ESMC2)
9. Communication Adaptor (CZ-CFUNC2)
10. Remote Sensor (CZ-CSRC2)
11. LonWorks Interface (CZ-CLNC2)
12. Seri-Para I/O unit for outdoor unit (CZ-CAPDC2)
13. MINI Seri-para I/O Unit (CZ-CAPBC2)
14. Local Adaptor for ON/OFF Controller (CZ-CAPC2)
15. Web Interface (CZ-CWEBC2)
*
Refer to the 2WAY SYSTEM TECHNICAL DATA (TD831159)
Section 4: MINI VRF SYSTEM UNIT SPECIFICATIONS ........................................................
1. Outdoor Unit..........................................................................................................
2. Indoor Unit
2. Indoor Unit
*
Refer to the 2WAY SYSTEM TECHNICAL DATA (TD831159)
Section 5: TEST RUN ...............................................................................................................
1. Preparing for Test Run .........................................................................................
2. Test Run Procedure .............................................................................................
3. Main Outdoor Unit PCB Setting ...........................................................................
4. Auto Address Setting ...........................................................................................
5. Remote Controller Test Run Settings ................................................................
6. Caution for Pump Down .....................................................................................
7. Meaning of Alarm Messages .............................................................................
2. Test Run Procedure .............................................................................................
3. Main Outdoor Unit PCB Setting ...........................................................................
4. Auto Address Setting ...........................................................................................
5. Remote Controller Test Run Settings ................................................................
6. Caution for Pump Down .....................................................................................
7. Meaning of Alarm Messages .............................................................................
Section 6: ELECTRICAL DATA ...............................................................................................
1. Outdoor Unit.........................................................................................................
2. Indoor Unit
2. Indoor Unit
*
Refer to the 2WAY SYSTEM TECHNICAL DATA (TD831159)
Contents
TD831155-04_MINI VRF.indb Sec1:iv
TD831155-04_MINI VRF.indb Sec1:iv
2014/08/26 17:37:47
2014/08/26 17:37:47
v
Contents
Section 7: PCB AND FUNCTIONS ..........................................................................................
1. Outdoor Unit Control PCB ....................................................................................
2. Indoor Unit Control PCB Switches and Functions
* Refer to the 2WAY SYSTEM TECHNICAL DATA (TD831159)
2. Indoor Unit Control PCB Switches and Functions
* Refer to the 2WAY SYSTEM TECHNICAL DATA (TD831159)
7-1
7-2
7-2
Section 8: RENEWAL ..............................................................................................................
1. Precautions on Renewal Design & Installation ....................................................
2. Reference ..........................................................................................................
2. Reference ..........................................................................................................
8-1
8-2
8-2
8-10
3. INSTALLATION INSTRUCTIONS (VRF Renewal Kit) ......................................8-12
Section 9: CAPACITY TABLE .................................................................................................
1. Capacity Ratio of Outdoor Unit ............................................................................
2. Cooling Capacity of Indoor Unit .........................................................................
2. Cooling Capacity of Indoor Unit .........................................................................
9-1
9-2
9-2
9-26
TD831155-04_MINI VRF.indb Sec1:v
TD831155-04_MINI VRF.indb Sec1:v
2014/08/26 17:37:47
2014/08/26 17:37:47
1 - 1
Outline of Mini VRF SYSTEM
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
1. OUTLINE OF MINI VRF SYSTEM
1. Line-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
2. MARKINGS FOR DIRECTIVE 97/23/EC (PED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Contents
TD831155-04_MINI VRF.indb 1
TD831155-04_MINI VRF.indb 1
2014/01/07 11:46:59
2014/01/07 11:46:59
1 - 2
Outline of Mini VRF SYSTEM
1
2
3
4
5
6
7
8
9
1. Line-up
Indoor units
Capacity: kW
(BTU/h) Cooling
(BTU/h) Cooling
/
Heating
Type
28
22
36
56
73
90
106
140
160
S-22MU1E5
S-28ML1E5
S-36ML1E5
S-56ML1E5
S-73ML1E5
S-28MD1E5
S-36MD1E5
S-56MD1E5
S-73MD1E5
S-22MP1E5
S-22MR1E5
S-28MP1E5
S-36MP1E5
S-56MP1E5
S-71MP1E5
S-28MR1E5
S-36MR1E5
S-56MR1E5
S-71MR1E5
Wall Mounted
Type
(K1 Type)
Type
(K1 Type)
Wall Mounted
Type
(K2 Type)
Type
(K2 Type)
Low Silhouette
Ducted Type
(F1 Type)
Ducted Type
(F1 Type)
Slim Low Static
Ducted Type
(M1 Type)
Ducted Type
(M1 Type)
Floor Standing
Type
(P1 Type)
Type
(P1 Type)
Concealed Floor
Standing Type
(R1 Type)
Standing Type
(R1 Type)
2.2 (7,500)
2.5 (8,500)
/
2.8 (9,600)
3.2 (11,000)
/
3.6 (12,000)
4.2 (14,000)
/
10.6 (36,000)
11.4 (39,000)
/
14.0 (47,800)
16.0 (54,600)
/
16.0 (54,600)
18.0 (61,500)
/
7.3 (25,000)
8.0 (27,000)
/
9.0 (30,000)
10.0 (34,000)
/
5.6 (19,000)
6.3 (21,000)
/
60
6.0 (20,500)
7.1 (24,200)
/
45
S-36MU1E5
S-28MU1E5
S-45MU1E5
S-36MY1E5
S-28MY1E5
S-22MY1E5
S-56MY1E5
S-45MY1E5
S-36MM1E5
S-28MM1E5
S-22MM1E5
S-56MM1E5
S-45MM1E5
S-45ML1E5
S-56MT1E5
S-36MT1E5
S-22MK1E5
S-28MK1E5
S-36MK1E5
S-22MK2E5
S-28MK2E5
S-36MK2E5
S-73MT1E5
S-106MT1E5
S-140MT1E5
S-45MT1E5
S-45MD1E5
S-28MF1E5
S-22MF1E5
S-36MF1E5
S-56MF1E5
S-73MF1E5
S-90MF1E5
S-106MF1E5
S-140MF1E5
S-160MF1E5
S-45MF1E5
S-45MP1E5
S-45MR1E5
4.5 (15,000)
5.0 (17,000)
/
S-22ML1E5
4-Way Cassette
Type
(U1 Type)
Type
(U1 Type)
4-Way Cassette
60×60 Type
(Y1 Type)
60×60 Type
(Y1 Type)
4-Way Cassette
60×60 Type
(Y2 Type)
60×60 Type
(Y2 Type)
2-Way Cassette
Type
(L1 Type)
Type
(L1 Type)
Ceiling Type
(T1 Type)
(T1 Type)
1-Way Cassette
Type (D1 Type)
Type (D1 Type)
S-56MU1E5
S-73MU1E5
S-106MU1E5
S-140MU1E5
S-160MU1E5
S-22MU1E51
S-36MU1E51
S-28MU1E51
S-45MU1E51
S-56MU1E51
S-60MU1E51
S-73MU1E51
S-90MU1E51
S-106MU1E51 S-140MU1E51 S-160MU1E51
Low Silhouette
Ducted Type
(F2 Type)
Ducted Type
(F2 Type)
S-28MF2E5
S-22MF2E5
S-36MF2E5
S-56MF2E5
S-73MF2E5
S-90MF2E5
S-106MF2E5
S-140MF2E5
S-160MF2E5
S-45MF2E5
S-36MY2E5
S-28MY2E5
S-22MY2E5
S-56MY2E5
S-45MY2E5
S-45MK1E5
S-56MK1E5
S-73MK1E5
S-106MK1E5
S-60MF2E5
Type
73
106
140
High Static Pressure
Ducted Type
(E1 Type)
Ducted Type
(E1 Type)
S-73ME1E5
S-106ME1E5
S-140ME1E5
TD831155-04_MINI VRF.indb 2
TD831155-04_MINI VRF.indb 2
2014/01/07 11:46:59
2014/01/07 11:46:59
Click on the first or last page to see other U-4LE1E5 / U-4LE1E8 / U-5LE1E5 / U-5LE1E8 / U-6LE1E5 / U-6LE1E8 (serv.man2) service manuals if exist.