How to pull the piping and drain hose out, in case of the
embedded piping.
embedded piping.
•
In case of left piping how to insert the
connection cable and drain hose.
connection cable and drain hose.
Rear view for left piping installation
Drain cap
Drain hose
Adjust the piping slightly
downwards.
downwards.
Drain hose
Connection cable
PVC tube
for drain
hose
for drain
hose
Indoor unit
Piping
Cable
Apply putty or
caulking material
to seal the wall
opening.
caulking material
to seal the wall
opening.
Connection cable
Piping
More than
470 mm
PVC tube (VP-65) for piping
and connection cable
and connection cable
PVC tube for drain hose (VP-30)
PVC tube for drain
hose (VP-20)
hose (VP-20)
More than 700 mm
Drain hose
from main unit
from main unit
Cable
45°
Drain
hose
hose
Piping
Sleeve for piping hole
Drain hose
Piping
Connection cable
More than 950 mm
(For the right piping, follow the same procedure)
Exchange the drain hose and
the cap
the cap
(3/4 ~ 1.75HP) or
1150 mm (2.0 ~ 2.5HP)
1150 mm (2.0 ~ 2.5HP)
More than 950 mm
(3/4 ~ 1.75HP) or
1150 mm (2.0 ~ 2.5HP)
70 mm (3/4 ~ 1.75HP) or
80 mm (2.0 ~ 2.5HP)
12.2.4 Connect the Cable to the Indoor Unit
The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille.
1 Install the indoor unit on the installing holder that mounted on the wall.
2 Open the front panel and grille door by loosening the screw.
3 Cable connection to the power supply through Isolating Devices (Disconnecting means).
2 Open the front panel and grille door by loosening the screw.
3 Cable connection to the power supply through Isolating Devices (Disconnecting means).
o
Connect the approved polychloroprene sheathed power supply cord 3 × 1.5 mm
2
(3/4 ~ 1.75HP) or
3 × 2.5 mm
2
(2.0 ~ 2.5HP), type designation 60245 IEC 57 or heavier cord to the terminal board, and
connect the other end of the cable to Isolating Devices (Disconnecting means).
o
Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or
otherwise) is too short.
otherwise) is too short.
o
In unavoidable case, joining of power supply cord between isolating devices and terminal board of air
conditioner shall be done by using approved socket and plug rated 15/16A (3/4 ~ 1.75HP) or 16A
(2.0HP) or 20A (2.5HP). Wiring work to both socket and plug must follow to national wiring standard.
conditioner shall be done by using approved socket and plug rated 15/16A (3/4 ~ 1.75HP) or 16A
(2.0HP) or 20A (2.5HP). Wiring work to both socket and plug must follow to national wiring standard.
4 Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement.
5 Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed
5 Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed
4 × 1.5 mm
2
(3/4 ~ 1.75HP) or 4 × 2.5 mm
2
(2.0 ~ 2.5HP) flexible cord, type designation 60245 IEC 57 or
heavier cord.
6 Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right
escapement.
54
7 Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor
unit according to the diagram below.
Terminals on the outdoor unit
S1
2
3
1
2
3
Colour of wires (connection cable)
Terminals on the indoor unit
L
1
N
S1
2
3
OR
L
1
N
S1
2
3
(Power supply cord)
*
Connection for multi inverter
model (Outdoor power
supply)
model (Outdoor power
supply)
Terminals on the isolating devices
(Disconnecting means)
(Disconnecting means)
(L) (N)
8 Secure the power supply cord and connection cable onto the control board with the holder.
9 Close grille door by tighten with screw and close the front panel.
9 Close grille door by tighten with screw and close the front panel.
Connection cable
Power supply cord
Terminal Board
Control
Board
Board
Recommended
length (mm)
Earth Wire
longer than
others
AC wires
for safety
reason
longer than
others
AC wires
for safety
reason
Holder
Holder
Indoor & outdoor
connection cable
Power supply
cord
Outdoor unit
Isolating Devices
Tape
Tape
Recommended
length (mm)
length (mm)
a
b
c
d
e
f
g
55 35 35 50 40 35 60
WARNING
This equipment must be properly earthed.
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the
electrical safety in case of the slipping out of the cord from the anchorage.
55
12.2.4.1 Wire Stripping Connecting and Requirement
WARNING
RISK OF FIRE
JOINING OF
WIRES MAY
CAUSE
OVERHEATING
AND FIRE.
WIRES MAY
CAUSE
OVERHEATING
AND FIRE.
Do not joint wires
OR
OR
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national
wiring rules.
Wire stripping
No loose strand
when inserted
when inserted
10 ± 1 mm
5 mm or more
Indoor/outdoor
connection
terminal board
connection
terminal board
(gap between wires)
Conductor
fully inserted
Conductor over
inserted
Conductor not
fully inserted
ACCEPT
PROHIBITED
PROHIBITED
12.2.4.2 Cutting
and
Flaring the Piping
1 Please cut using pipe cutter and then remove the burrs.
2 Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end
2 Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end
down to avoid the metal powder entering the pipe.
3 Please make flare after inserting the flare nut onto the copper pipes.
When properly fl ared, the internal surface of the
fl are will evenly shine and be of even thickness.
Since the fl are part comes into contact with the
connections, carefully check the fl are fi nish.
fl are will evenly shine and be of even thickness.
Since the fl are part comes into contact with the
connections, carefully check the fl are fi nish.
Improper fl aring
Inclined Surface
damaged
Cracked Uneven
thickness
1. To cut
2. To remove burrs
3. To fl are
Bar
Red arrow mark
Handle
Core
Yoke
Clamp handle
Bar
0 – 0.5 mm
Copper pipe
Reamer
Point down
Pipe
12.2.5 Connect the Piping
12.2.5.1 Connecting
the Piping to Indoor
For connection joint of all model (except R32 model)
Please make flare after inserting flare nut (locate at
joint portion of tube assembly) onto the copper pipe.
(In case of using long piping)
Connect the piping
Please make flare after inserting flare nut (locate at
joint portion of tube assembly) onto the copper pipe.
(In case of using long piping)
Connect the piping
Align the center of piping and sufficiently tighten
the flare nut with fingers.
Further tighten the flare nut with torque wrench in
specified torque as stated in the table.
Torque
wrench
Spanner or
Wrench
For connection joint location at inside building for R32
model only
model only
Decide the length.
Cut and remove the tube connectors at indoor
copper pipings (both gas and liquid piping) by
using pipe cutter. Remove burrs from cut edge.
using pipe cutter. Remove burrs from cut edge.
Use pipe expander to expand the end of long
piping.
Align the center of piping and braze the piping
joints.
Indoor
copper pipe
copper pipe
Tube connector
(40~50mm)
Brazing point
1. Cut and Remove
2. Expand long pipe
3. Braze both pipe
56
12.2.5.2 Connecting
the
Piping to Outdoor
Decide piping length and then cut by using pipe cutter.
Remove burrs from cut edge.
Make flare after inserting the flare nut (locate at valve)
onto the copper pipe. Align center of piping to valve
and then tighten with torque wrench to the specified
torque as stated in the table.
Remove burrs from cut edge.
Make flare after inserting the flare nut (locate at valve)
onto the copper pipe. Align center of piping to valve
and then tighten with torque wrench to the specified
torque as stated in the table.
Do not overtighten, overtightening may cause gas leakage.
Piping size
Torque
6.35 mm (1/4")
[18 N•m (1.8 kgf•m)]
9.52 mm (3/8")
[42 N•m (4.3 kgf•m)]
12.7 mm (1/2")
[55 N•m (5.6 kgf•m)]
15.88 mm (5/8")
[65 N•m (6.6 kgf•m)]
19.05 mm (3/4")
[100 N•m (10.2 kgf•m)]
12.2.5.3 Connecting the Piping to Outdoor Multi
Decide piping length and then cut by using pipe cutter.
Remove burrs from cut edge. Make flare after
inserting the flare nut (locate at valve) onto the copper
pipe. Align center of piping to valve and then tighten
with torque wrench to the specified torque as stated in
the table.
Remove burrs from cut edge. Make flare after
inserting the flare nut (locate at valve) onto the copper
pipe. Align center of piping to valve and then tighten
with torque wrench to the specified torque as stated in
the table.
Connection pipe
(female side)
Auxiliary pipe
(male side)
Flare Nut
Hall Union
Liquid side
* For Gas side piping please refer table and diagram below
Outdoor Multi Combination Model
Pipe size
(refer to
diagram)
R32 Model
R410A Model
CS-Z20***,
CS-XZ20***,
CS-Z25***,
CS-XZ25***,
CS-Z35***,
CS-XZ35***
CS-XZ20***,
CS-Z25***,
CS-XZ25***,
CS-Z35***,
CS-XZ35***
CU-2Z35***,
CU-2Z41***,
CU-2Z50***,
CU-3Z52***,
CU-3Z68***,
CU-4Z68***,
CU-4Z80***,
CU-5Z90***
CU-2Z41***,
CU-2Z50***,
CU-3Z52***,
CU-3Z68***,
CU-4Z68***,
CU-4Z80***,
CU-5Z90***
CU-2E12***,
CU-2E15***,
CU-2E18***,
CU-3E18***,
CU-3E23***,
CU-4E23***,
CU-4E27***,
CU-5E34***
CU-2E15***,
CU-2E18***,
CU-3E18***,
CU-3E23***,
CU-4E23***,
CU-4E27***,
CU-5E34***
CS-Z42***,
CS-Z50***,
CS-XZ50***
CS-Z50***,
CS-XZ50***
CU-2Z50***,
CU-3Z52***,
CU-3Z68***,
CU-4Z68***,
CU-4Z80***,
CU-5Z90***
CU-3Z52***,
CU-3Z68***,
CU-4Z68***,
CU-4Z80***,
CU-5Z90***
CU-2E18***,
CU-3E18***,
CU-3E23***,
CU-4E23***,
CU-4E27***,
CU-5E34***
CU-3E18***,
CU-3E23***,
CU-4E23***,
CU-4E27***,
CU-5E34***
(CZ-MA1P)
CS-Z71***
CU-4Z80***,
CU-5Z90***
CU-5Z90***
CU-4E27***,
CU-5E34***
CU-5E34***
(CZ-MA2P) &
(CZ-MA3P)
Hall Union
Connection pipe
(female side)
Auxiliary pipe
(male side)
Flare Nut
Hall Union
Packing
Connection pipe
(female side)
Auxiliary pipe
(male side)
Pipe size reducer (CZ-MA1P)
Flare Nut
Auxiliary pipe
(male side)
(Outdoor)
Auxiliary pipe
(male side)
(Indoor)
Hall Union
Hall Union
Packing
Packing
Connection pipe
(female side)
Pipe size expander
(CZ-MA2P)
Flare Nut
Pipe size reducer
(CZ-MA3P)
Gas side
Click on the first or last page to see other CS-Z20TKEW / CS-Z25TKEW / CS-Z35TKEW / CS-Z42TKEW / CS-Z50TKEW / CS-Z71TKEW / CS-XZ20TKEW / CS-XZ25TKEW / CS-XZ35TKEW / CS-XZ50TKEW / CU-Z20TKE / CU-Z25TKE / CU- / 35TKE / CU-Z42TKE / CU-Z50TKE / CU-Z71TKE / CU-Z20TKE / CU-Z25TKE / CU-Z35TKE / CU-Z50TKE service manuals if exist.