Panasonic CS-XE9EKE / CU-XE9EKE / CS-XE12EKE / CU-XE12EKE Service Manual ▷ View online
7
2.2.
CS-XE12EKE CU-XE12EKE
Unit
CS-XE12EKE
CU-XE12EKE
Performance Test Condition
EUROVENT/AS
Power Source
(Phase, Voltage, Cycle)
ø, V, Hz
Single, 230 - 240, 50
Cooling Capacity
kW
3.50 (0.60 - 4.00)
kcal/h
3,010 (520 - 3,440)
Heating Capacity
kW
4.80 (0.60 - 6.70)
kcal/h
4,130 (520 - 5,760)
Moisture Removal
l/h (Pint/h)
2.0 (4.2)
Airflow Method
OUTLET
SIDE VIEW
TOP VIEW
INTAKE
Air Volume
Lo
m
3
/min (cfm)
Cooling; 8.2 (290)
—
Heating; 9.2 (320)
Me
m
3
/min (cfm)
Cooling; 10.1 (360)
—
Heating; 10.8 (380)
Hi
m
3
/min (cfm)
Cooling; 11.9 (420)
Cooling; 31.0 (1,090)
Heating; 12.7 (450)
SHi
m
3
/min (cfm)
Cooling; 12.6 (450)
—
Heating; 13.2 (470)
Noise Level
dB (A)
Cooling; High 42 - 42, Low 29 - 29
Cooling; High 48 - 48
Heating; High 42 - 42, Low 33 - 33
Heating; High 50 - 50
Power level dB
Cooling; High 53 - 53
Cooling; High 61 - 61
Heating; High 53 - 53
Heating; High 63 - 63
Electrical Data
Input Power
W
Cooling; 880 (120 - 1,100)
Heating; 1,220 (115 - 1,840)
Running Current
A
Cooling; 4.1 - 4.0
Heating; 5.6 - 5.4
EER
W/W (kcal/hW)
Cooling; 3.98 (3.42)
COP
W/W (kcal/hW)
Heating; 3.93 (3.39)
Starting Current
A
5.6
Piping Connection Port
inch
G ; Half Union 1/2”
G ; 3-way valve 1/2”
(Flare piping)
inch
L ; Half Union 1/4”
L ; 2-way valve 1/4”
Pipe Size
inch
G ; (Gas side) 1/2”
G ; (Gas side) 1/2”
(Flare piping)
inch
L ; (Liquid side) 1/4”
L ; (Liquid side) 1/4”
Drain Hose
Inner diameter
mm
16
—
Length
m
0.65
—
Power Cord
Length
m
1.8
—
Number of core-wire
3 (1.5 mm
2
)
—
Dimensions
Height
inch (mm)
12 (305)
21 - 1/4 (540)
Width
inch (mm)
34 - 1/4 (870)
30 - 23/32 (780)
Depth
inch (mm)
9 - 1/32 (229)
11 - 3/8 (289)
Net Weight
lb (kg)
29 (13.0)
82 (37)
Compressor
Description
—
Hermetic Scroll
Motor
Type
—
Brushless (4-poles)
Rated
Output
W
—
750
Air Circulation
Description
Cross-flow Fan
Propeller Fan
Material
ASG20K1
P.P
Motor
Type
Transistor (8-poles)
Induction (8-poles)
Input
W
44.3
65.9
Rated
Output
W
30
40
Fan Speed Low (Cool/Heat)
rpm
900 / 1,000
—
Medium (Cool/Heat)
rpm
1,100 / 1,180
—
High (Cool/Heat)
rpm
1,300 / 1,380
840/820
SuperHigh (Cool/Heat)
rpm
1,380 / 1,440
—
8
Note:
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 / 15
2 / 24
FPI
20
17
Size (W
u H u L)
mm
610
u 315 u 25.4
718.4
u 504 u 36.4
689.8
Refrigerant Control Device
—
Exp. Valve
Refrigerations Oil
(cm
3
)
—
RB68A (400)
Refrigerant (R410A)
g (oz)
—
970 (34.2)
Thermostat
Electronic Control
—
Protection Device
—
Electronic Control
Capillary Tube
Length
mm
—
—
Flow Rate
I/min
—
—
Inner Diameter
mm
—
—
Air Filter
Material
PET
—
Style
Compressor Capacitor
PF, VAC
—
—
Fan Motor Capacitor
PF, VAC
—
—
Unit
CS-XE12EKE
CU-XE12EKE
9
3 Features
• High Efficiency
• Compact Design
• Wider range of horizontal discharge air
• Long Installation Piping
- up to 15 meter for XE9EK & XE12EK
• SUPER alleru buster
- Inactivate various harmful airborne elements including
allergens, viruses and bacteria
• Operation Improvement
- Quiet mode to provide quiet operation
- Powerful mode to reach the desired room temperature
- Powerful mode to reach the desired room temperature
quickly
- 24-hour timer setting
- Ventilation mode is to ventilate the dirty air of the room to
- Ventilation mode is to ventilate the dirty air of the room to
outdoor, to keep the room fresh and clean
- Random Auto Restart after power failure for safety
restart operation
• Serviceability Improvement
- Removable and washable front panel
- Breakdown Self Diagnosis function
- Breakdown Self Diagnosis function
• Filter Cleaning Control
- Cleans the filter automatically, to keep optimum perfor-
mance under clean and comfortable environment.
- This built-in cleaning mechanism cleans the filter auto-
matically and minimizes filter clogging
- It maintains the original performance of the air condi-
tioner, while eliminates the unpleasant job of manual fil-
ter cleaning
ter cleaning
• Environmental Protection
- Non-ozone depletion substances refrigerant (R410A).
10
4 Location of Controls and Components
Note:
* Movable front panel will open slightly for air intake purposes
once the air conditioner operation starts. Movable front panel
will remain open during air conditioner operation. It will close
automatically once the air conditioner operation stops. In such
a condition, do not interrupt the movable front panel movement
as this may cause malfunction or unit breakdown. The above
condition does not apply for filter cleaning.
* Movable front panel will open slightly for air intake purposes
once the air conditioner operation starts. Movable front panel
will remain open during air conditioner operation. It will close
automatically once the air conditioner operation stops. In such
a condition, do not interrupt the movable front panel movement
as this may cause malfunction or unit breakdown. The above
condition does not apply for filter cleaning.
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
Click on the first or last page to see other CS-XE9EKE / CU-XE9EKE / CS-XE12EKE / CU-XE12EKE service manuals if exist.