DOWNLOAD Panasonic CS-XE9EKE / CU-XE9EKE / CS-XE12EKE / CU-XE12EKE Service Manual ↓ Size: 7.38 MB | Pages: 79 in PDF or view online for FREE

Model
CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE
Pages
79
Size
7.38 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-xe9eke-cu-xe9eke-cs-xe12eke-cu-xe12eke.pdf
Date

Panasonic CS-XE9EKE / CU-XE9EKE / CS-XE12EKE / CU-XE12EKE Service Manual ▷ View online

7
2.2.
CS-XE12EKE CU-XE12EKE
Unit
CS-XE12EKE
CU-XE12EKE
Performance Test Condition
EUROVENT/AS
Power Source 
(Phase, Voltage, Cycle)
ø, V, Hz
Single, 230 - 240, 50
Cooling Capacity
kW
3.50 (0.60 - 4.00)
kcal/h
3,010 (520 - 3,440)
Heating Capacity
kW
4.80 (0.60 - 6.70)
kcal/h
4,130 (520 - 5,760)
Moisture Removal
l/h (Pint/h)
2.0 (4.2)
Airflow Method
OUTLET
SIDE VIEW
TOP VIEW
INTAKE
Air Volume
Lo
m
3
/min (cfm)
Cooling; 8.2 (290)
Heating; 9.2 (320)
Me
m
3
/min (cfm)
Cooling; 10.1 (360)
Heating; 10.8 (380)
Hi
m
3
/min (cfm)
Cooling; 11.9 (420)
Cooling; 31.0 (1,090)
Heating; 12.7 (450)
SHi
m
3
/min (cfm)
Cooling; 12.6 (450)
Heating; 13.2 (470)
Noise Level
dB (A)
Cooling; High 42 - 42, Low 29 - 29
Cooling; High 48 - 48
Heating; High 42 - 42, Low 33 - 33
Heating; High 50 - 50
Power level dB
Cooling; High 53 - 53
Cooling; High 61 - 61
Heating; High 53 - 53
Heating; High 63 - 63
Electrical Data
Input Power
W
Cooling; 880 (120 - 1,100)
Heating; 1,220 (115 - 1,840)
Running Current
A
Cooling; 4.1 - 4.0
Heating; 5.6 - 5.4
EER
W/W (kcal/hW)
Cooling; 3.98 (3.42)
COP
W/W (kcal/hW)
Heating; 3.93 (3.39)
Starting Current
A
5.6
Piping Connection Port
inch
G ; Half Union 1/2”
G ; 3-way valve 1/2”
(Flare piping)
inch
L ; Half Union 1/4”
L ; 2-way valve 1/4”
Pipe Size
inch
G ; (Gas side) 1/2”
G ; (Gas side) 1/2”
(Flare piping)
inch
L ; (Liquid side) 1/4”
L ; (Liquid side) 1/4”
Drain Hose
Inner diameter
mm
16
Length
m
0.65
Power Cord
Length
m
1.8
Number of core-wire
3 (1.5 mm
2
)
Dimensions
Height
inch (mm)
12 (305)
21 - 1/4 (540)
Width
inch (mm)
34 - 1/4 (870)
30 - 23/32 (780)
Depth
inch (mm)
9 - 1/32 (229)
11 - 3/8 (289)
Net Weight
lb (kg)
29 (13.0)
82 (37)
Compressor
Description
Hermetic Scroll
Motor
Type
Brushless (4-poles)
Rated
Output
W
750
Air Circulation
Description
Cross-flow Fan
Propeller Fan
Material
ASG20K1
P.P
Motor
Type
Transistor (8-poles)
Induction (8-poles)
Input
W
44.3
65.9
Rated
Output
W
30
40
Fan Speed Low (Cool/Heat)
rpm
900 / 1,000
Medium (Cool/Heat)
rpm
1,100 / 1,180
High (Cool/Heat)
rpm
1,300 / 1,380
840/820
SuperHigh (Cool/Heat)
rpm
1,380 / 1,440
8
Note:
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 / 15
2 / 24
FPI
20
17
Size (W 
u H u L)
mm
610 
u 315 u 25.4
718.4 
u 504 u 36.4
           689.8
Refrigerant Control Device
Exp. Valve
Refrigerations Oil
(cm
3
)
RB68A (400)
Refrigerant (R410A)
g (oz)
970 (34.2)
Thermostat
Electronic Control
Protection Device
Electronic Control
Capillary Tube
Length
mm
Flow Rate
I/min
Inner Diameter
mm
Air Filter
Material
PET
Style
Compressor Capacitor
PF, VAC
Fan Motor Capacitor
PF, VAC
Unit
CS-XE12EKE
CU-XE12EKE
9
3 Features
• High Efficiency
• Compact  Design
• Wider range of horizontal discharge air
• Long Installation Piping
up to 15 meter for XE9EK & XE12EK
• SUPER alleru buster
- Inactivate various harmful airborne elements including
allergens, viruses and bacteria
• Operation Improvement
Quiet mode to provide quiet operation
- Powerful mode to reach the desired room temperature
quickly
- 24-hour timer setting
- Ventilation mode is to ventilate the dirty air of the room to
outdoor, to keep the room fresh and clean
- Random Auto Restart after power failure for safety
restart operation
• Serviceability Improvement
Removable and washable front panel
Breakdown Self Diagnosis function
• Filter Cleaning Control
- Cleans the filter automatically, to keep optimum perfor-
mance under clean and comfortable environment. 
- This built-in cleaning mechanism cleans the filter auto-
matically and minimizes filter clogging
- It maintains the original performance of the air condi-
tioner, while eliminates the unpleasant job of manual fil-
ter cleaning
• Environmental Protection
- Non-ozone depletion substances refrigerant (R410A). 
10
4 Location of Controls and Components
Note:
* Movable front panel will open slightly for air intake purposes
once the air conditioner operation starts. Movable front panel
will remain open during air conditioner operation. It will close
automatically once the air conditioner operation stops. In such
a condition, do not interrupt the movable front panel movement
as this may cause malfunction or unit breakdown. The above
condition does not apply for filter cleaning.
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
Page of 79
Display

Click on the first or last page to see other CS-XE9EKE / CU-XE9EKE / CS-XE12EKE / CU-XE12EKE service manuals if exist.