Panasonic CS-XE9CKE / CU-XE9CKE / CS-XE12CKE / CU-XE12CKE Service Manual ▷ View online

Outdoor Unit
30 seconds Forced Operation
Time Delay Safety Control
Overload Protection
Deice Operation
Compressor Overheating
Prevention Control
IPM (Power Transistor)
Overheating Protection Control
Total Running Current Control
Low Operation Frequency
Protection Control
Outdoor Air Temperature
Control
5
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE
3 Product Specifications
Unit
CS-XE9CKE
CU-XE9CKE
Cooling Capacity
kW
kcal/h
BTU/h
2.6 (0.60 - 3.00)
2,240 (520 - 2,580)
8,870 (2,050 - 10,200)
Heating Capacity
kW
kcal/h
BTU/h
3.6 (0.60 - 5.00)
3,100 (520 - 4,300)
12,300 (2,050 - 17,100)
Moisture Removal
l/h
Pint/h
1.6
(3.4)
Power Source
Phase
V
Cycle
Single
230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Indoor Air (Lo)
m
3
/min (cfm)
Cooling; 6.5 (231)
Heating; 7.1 (249)
Indoor Air (Me)
m
3
/min (cfm)
Cooling; 8.1 (286)
Heating; 8.8 (312)
Indoor Air (Hi)
m
3
/min (cfm)
Cooling; 9.9 (350)
Cooling; 30.0 (1,060)
Heating; 10.6 (370)
dB (A)
Cooling; High 39, Low 26
Cooling; 46
Heating; High 40, Low 27
Heating; 47
Noise Level
Power level dB
Cooling; High 50
Cooling; High 59
Heating; High 51
Heating; High 60
Electrical Data
Input
W
Cooling; 700 (115 - 880)
Heating; 900 (110 - 1,400)
Running Current
A
Cooling; 3.3
Heating; 4.0
EER
W/W (kcal/hw), BTU/hw
Cooling; 3.71(3.20), 12.7
COP
W/W (kcal/hw), BTU/hw
Heating; 4.00 (3.44), 13.7
Starting Current
A
4.00
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 3/8”
L ; Half Union 1/4”
G ; 3-way valve 3/8”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 3/8”
L (liquid side) ; 1/4”
G (gas side) ; 3/8”
L (liquid side) ; 1/4”
6
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE
Unit
CS-XE9CKE
CU-XE9CKE
Drain
Hose
Inner diameter
mm
12
Length
m
0.65
Power Cord Length
Number of core-wire
2.1 m
3 core wires × 1.0 mm
2

Dimensions
Height
inch (mm)
10 - 26/32 (275)
21 - 9/32 (540)
Width
inch (mm)
31 - 15/32 (799)
30 - 23/32 (780)
Depth
inch (mm)
9 - 9/32 (236)
11 - 3/8 (289)
Net Weight
lb (kg)
22 (10.0)
84 (38)
Compressor
Type
Involute scroll
Motor
Type
Brushless (4-pole)
Rated
Output
W
700
Air Circulation
Type
Cross-flow Fan
Propeller Fan
Material
AS + Glass Fiber 20%
P.P
Motor
Type
Transistor (8-poles)
Induction (6-poles)
Input
W
61.3
Rate Output
W
30
25
Fan Speed
Lo (Cool/Heat)
rpm
800 / 840
Me (Cool/Heat)
rpm
1,000 / 1,040
Hi (Cool/Heat)
rpm
1,200 / 1,270
770
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium (Blue Coated)
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 / 15
1 / 20
FPI
21
19
Size (W × H × L)
mm
610 × 315 × 25.4
732.1 × 508 × 22
Refrigerant Control Device
Capillary Tube
Refrigeration Oil
(c.c)
RB68A (360)
Refrigerant (R410A)
g (oz)
840 (29.7)
Thermostat
Electronic Control
Protection Device
Electronic Control
Electronic Control
Length
mm
C1, C2 ; 1,100, C3 ; 440
Capillary Tube
Flow Rate
l/min
C1, C2 ; 5.0, C3 ; 18.6
Inner Diameter
mm
C1, C2 ; 1.2, C3 ; 1.7
Air Filter
Material
Style
P.P.
Honeycomb
Fan Motor Capacitor
µF, VAC
1.8 µF, 400 VAC
     • 
• 
• 
• Specifications are subject to change without notice for further improvement.
7
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE
Unit
CS-XE12CKE
CU-XE12CKE
Cooling Capacity
kW
kcal/h
BTU/h
3.45 (0.60 - 4.00)
2,970 (520 - 3,440)
11,800 (2,050 - 13,600)
Heating Capacity
kW
kcal/h
BTU/h
4.80 (0.60 - 6.50)
4,130 (520 - 5,590)
16,400 (2,050 - 22,200)
Moisture Removal
l/h
Pint/h
2.0
(4.2)
Power Source
Phase
V
Cycle
Single
230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Indoor Air (Lo)
m
3
/min (cfm)
Cooling; 7.3 (258)
Heating; 9.2 (325)
Indoor Air (Me)
m
3
/min (cfm)
Cooling; 9.2 (323)
Heating; 10.3 (360)
Indoor Air (Hi)
m
3
/min (cfm)
Cooling; 10.9 (380)
Cooling; 31.0 (1,090)
Heating; 11.8 (420)
dB (A)
Cooling; High 42, Low 29
Cooling; 48
Heating; High 42, Low 33
Heating; 50
Noise Level
Power level dB
Cooling; High 53
Cooling; High 61
Heating; High 53
Heating; High 63
Electrical Data
Input
W
Cooling; 950 (120 - 1,280)
Heating; 1,260 (115 - 1,890)
Running Current
A
Cooling; 4.4
Heating; 5.6
EER
W/W (kcal/hw), BTU/hw
Cooling; 3.63 (3.13), 12.4
COP
W/W (kcal/hw), BTU/hw
Heating; 3.81 (3.28), 13.0
Starting Current
A
5.60
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 1/2”
L ; Half Union 1/4”
G ; 3-way valve 1/2”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
Drain
Hose
Inner diameter
mm
12
Length
m
0.65
Power Cord Length
Number of core-wire
2.1 m
3 core wires × 1.0 mm
2

8
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE
Page of 110
Display

Click on the first or last page to see other CS-XE9CKE / CU-XE9CKE / CS-XE12CKE / CU-XE12CKE service manuals if exist.