DOWNLOAD Panasonic CS-XE18HKD / CS-XE24HKD / CU-XE18HKD / CU-XE24HKD Service Manual ↓ Size: 8.9 MB | Pages: 79 in PDF or view online for FREE

Model
CS-XE18HKD CS-XE24HKD CU-XE18HKD CU-XE24HKD
Pages
79
Size
8.9 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-xe18hkd-cs-xe24hkd-cu-xe18hkd-cu-xe24hkd.pdf
Date

Panasonic CS-XE18HKD / CS-XE24HKD / CU-XE18HKD / CU-XE24HKD Service Manual ▷ View online

29
10.2.3.
Power Printed Circuit Board
30
10.2.4.
Noise Filter Printed Circuit Board
31
11 Installation Instruction
11.1. Select The Best Location
INDOOR UNIT
• There should not be any heat source or steam near the unit.
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
• Recommended installation height for indoor unit shall be at
least 2.5 m.
OUTDOOR UNIT
• If an awning is built over the unit to prevent direct sunlight or
rain, be careful that heat radiation from the condenser is not
obstructed.
• There should not be any animal or plant which could be
affected by hot air discharged.
• Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
• Do not place any obstacles which may cause a short circuit
of the discharged air.
• If piping length is over 10 m, additional refrigerant should be
added as shown in the table.
Example : For XE18HKD
If the unit is installed at a 15 m distance, the quantity of
additional refrigerant should be 100 g ...... (15 - 10) m x 20 g/m
= 100 g.
11.2. Indoor/Outdoor Unit 
Installation Diagram
Model
Piping size Rated 
Length 
(m)
Max
Elevation 
(m)
Min.
Piping
Length 
(m)
Max.   
Piping
Length 
(m)
Additional
Refrigerant 
(g/m)
Gas Liquid
XE18HKD 1/2”
1/4”
5
15
3
20
20
XE24HKD 5/8”
1/4”
5
20
3
30
30
32
11.3. Indoor Unit
11.3.1.
HOW TO FIX INSTALLATION PLATE
The mounting wall is strong and solid enough to prevent it from
the vibration.
The centre of installation plate should be at more than 550 mm
at right and left of the wall. 
The distance from installation plate edge to ceiling should more
than 67 mm.
From installation plate left edge to unit’s left side is 47 mm.
From installation plate right edge to unit’s right is 73 mm.
1. Mount the installation plate on the wall with 5 screws or
more.
(If mounting the unit on the concrete wall consider using
anchor bolts.)
• Always mount the installation plate horizontally by
aligning the marking-off line with the thread and using a
level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
• Line according to the left and right side of the installation
plate. The meeting point of the extended line is the
centre of the hole. Another method is by putting
measuring tape at position as shown in the diagram
above. The hole centre is obtained by measuring the
distance namely 150 mm and 125 mm for left and right
hole respectively.
• Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
11.3.2.
TO DRILL A HOLE IN THE WALL
AND INSTALL A SLEEVE OF
PIPING
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the
wall.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
11.3.3.
INDOOR UNIT INSTALLATION
1. For the right rear piping
2. For the right and right bottom piping
: For left side piping, piping connection for liquid should be about
126 mm from this line.
: For left side piping, piping connection for gas should be about
174 mm from this line.
: For left side piping, piping connection cable should be about
984 mm from this line.
Caution
When the wall is hollow, please be sure to use the
sleeve for tube ass’y to prevent dangers caused by
mice biting the connecting cable.
Page of 79
Display

Click on the first or last page to see other CS-XE18HKD / CS-XE24HKD / CU-XE18HKD / CU-XE24HKD service manuals if exist.