DOWNLOAD Panasonic CS-W7NKD / CS-W9NKD / CS-W12NKD / CS-W18NKD / CS-W24NKD / CU-W7NKD / CU-W9NKD / CU-W12NKD / CU-W18NKD / CU-W24NKD Service Manual ↓ Size: 7.55 MB | Pages: 116 in PDF or view online for FREE

Model
CS-W7NKD CS-W9NKD CS-W12NKD CS-W18NKD CS-W24NKD CU-W7NKD CU-W9NKD CU-W12NKD CU-W18NKD CU-W24NKD
Pages
116
Size
7.55 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-w7nkd-cs-w9nkd-cs-w12nkd-cs-w18nkd-cs-w24nkd-cu.pdf
Date

Panasonic CS-W7NKD / CS-W9NKD / CS-W12NKD / CS-W18NKD / CS-W24NKD / CU-W7NKD / CU-W9NKD / CU-W12NKD / CU-W18NKD / CU-W24NKD Service Manual ▷ View online

53 
 
For CS-W18NKD and CS-W24NKD 
 
 
12.8  Horizontal Airflow Direction Control 
12.8.1 Auto 
Control 
  When the horizontal airflow is set to Auto using the remote control, the vanes swings left and right as shown in 
the diagram. 
  When stopped with remote control, the discharge vanes are reset and stop at the reset position. 
  During Cooling operation or Soft Dry operation or Heating operation, indoor fan motor may stop to rotate at 
certain periods. At that condition, the vane will stop swinging and rest at face front position. 
 
For CS-W7NKD, CS-W9NKD and CS-W12NKD 
 
 
 
For CS-W18NKD and CS-W24NKD 
 
 
 
54 
12.8.2 Manual 
Control 
  When the horizontal airflow direction is set to Manual using the remote control, the automatic airflow is released 
and the airflow direction vane move left and right in the range shown in the diagram. 
  The louver can be adjusted by pressing the button to the desired vane position. 
  When stopped with remote control, the vanes is reset and stopped at reset position. 
 
For CS-W7NKD, CS-W9NKD and CS-W12NKD 
 
 
 
Pattern  1 2 3 4 5 
Airflow Direction Patterns 
at Remote Control 
 
 
 
 
 
Vane Angle (°) 
25 
50 
37.5 
12.5 
 
For CS-W18NKD and CS-W24NKD 
 
 
 
Pattern  1 2 3 4 5 
Airflow Direction Patterns 
at Remote Control 
 
 
 
 
 
Vane Angle (°) 
20 
40 
30 
10 
 
55 
12.9 Powerful Operation 
  To achieve the setting temperature quickly. 
 
(Cooling and Soft Dry Operation condition) 
  When Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against 
the present setting temperature (Lower temperature limit: 16°C). 
  This operation automatically will be running under SHi Fan Speed (Cooling). 
  Vertical Airflow Direction:-  
o  In “Manual” setting, the vane will automatically shift down 10° lower than previous setting. 
o  In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° 
downward. 
 
(Heating Operation condition) 
  When Powerful operation is set, the setting temperature will be automatically increased 3°C against the present 
setting temperature (Higher temperature: 30°C). 
  The Fan Speed will shift as shown below: 
 
 
CS-W7NKD  CS-W9NKD  CS-W12NKD 
 
 
CS-W18NKD  CS-W24NKD 
 
  Vertical Airflow Direction:-  
o  In “Manual” setting, the vane will automatically shift down 5° lower than previous setting. 
o  In “Auto” setting, the vane will automatically shift between upper and lower limit depending on the intake air 
temperature as Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be 
shifted 5° downward. 
56 
  Powerful operation stops when:-  
o  Powerful operation has operate for 15 minutes. 
o  Powerful button is pressed again. 
o  Quiet button is pressed 
o  Stopped by OFF/ON operation button. 
o  Timer OFF activates. 
o  Operating mode is changed. 
12.10  Quiet Operation 
(For Cooling Operation or cooling region of Soft Dry Operation) 
  To provide quiet cooling operation condition. 
  Once the Quiet Operation is set at the remote control, the Quiet LED brightness will be dimmed. The sound level 
will reduce around 2dB(A) for Lo fan speed or 3dB(A) for Hi/Me fan speed against the present operation sound 
level. 
  Dew formation become severe at Quite Lo Cool, therefore Quiet Lo cool operated only for 1 hour 30 minutes  
(1 hour QLo, 30 minutes QLo + 80rpm) (for W7NKD, W9NKD and W12NKD) and Quiet Lo cool operated only  
1 hour 30 minutes (1 hour QLo, 30 minutes QLo + 50 rpm) (for W18NKD and W24NKD). 
  Manual Airflow Direction: 
o  RPM control during Lo cool 
 
(For CS-W7NKD, CS-W9NKD and CS-W12NKD) 
 
 
 
(For CS-W18NKD and CS-W24NKD) 
 
 
 
o  RPM control during Hi & Me cool 
 
 
 
Page of 116
Display