Panasonic CS-TZ60TKEW / CS-TZ71TKEW / CU-TZ60TKE / CU-TZ71TKE Service Manual ▷ View online
17
Multi Split Combination Possibility:
o A single outdoor unit enables air conditioning of up to three separate rooms for CU-3E18PBE.
o A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E23PBE, CU-4E27PBE.
o A single outdoor unit enables air conditioning of up to five separate rooms for CU-5E34PBE.
o A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E23PBE, CU-4E27PBE.
o A single outdoor unit enables air conditioning of up to five separate rooms for CU-5E34PBE.
CONNECTABLE INDOOR UNIT CU-3E18PBE* CU-4E23PBE*
CU-4E27PBE*
CU-5E34PBE*
ROOM
A B C A B C D A B C D A B C D E
Wall
1.6kW CS-MTZ16TKE ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
2.0kW CS-TZ20TKEW ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
2.5kW CS-TZ25TKEW ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
3.5kW CS-TZ35TKEW ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
4.2kW CS-TZ42TKEW ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
5.0kW CS-TZ50TKEW ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
6.0kW CS-TZ60TKEW – – – ●
●
●
●
●
●
●
●
●
●
●
●
●
7.1kW CS-TZ71TKEW – – – – – – – ●
●
●
●
●
●
●
●
●
Capacity range of connectable units From 4.5kW to 9.0kW From 4.5kW to 11.0kW
From 4.5kW to 13.6kW
From 4.5kW to 17.5kW
Pipe length
1 room maximum pipe length (m)
25
25
25
25
Allowable elevation (m)
15
15
15
15
Total allowable pipe length (m)
50
60
70
80
Total pipe length for maximum
chargeless length (m)
30 30 45
45
Additional gas amount over
chargeless length (g/m)
20 20 20
20
Note: “●” : Available
Remarks for CU-3E18PBE / CU-4E23PBE / CU-4E27PBE / CU-5E34PBE
1.
The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-4E27PBE. (Total nominal capacity of indoor units is between
4.5kW to 13.6kW)
1) Two CS-TZ25TKEW only. (Total nominal cooling capacity is 5.0kW)
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-4E27PBE. (Total nominal capacity of indoor units is between
4.5kW to 13.6kW)
1) Two CS-TZ25TKEW only. (Total nominal cooling capacity is 5.0kW)
Note*: Above outdoor unit is contains and operates with refrigerant R410A gas.
18
Multi Split Combination Possibility:
o A single outdoor unit enables air conditioning of up to two separate rooms for CU-2Z35TBE, CU-2Z41TBE,
CU-2Z50TBE.
CONNECTABLE INDOOR UNIT
OUTDOOR UNIT
CU-2Z35TBE CU-2Z41TBE CU-2Z50TBE
ROOM
A B A B A B
Wall
1.6kW
CS-MZ16TKE
●
●
●
●
●
●
CS-MTZ16TKE
2.0kW
CS-Z20TKEW
●
●
●
●
●
●
CS-XZ20TKEW
CS-TZ20TKEW
CS-TE20TKEW
2.5kW
CS-Z25TKEW
●
●
●
●
●
●
CS-XZ25TKEW
CS-TZ25TKEW
CS-TE25TKEW
CS-E9PD3EA
CS-E9PB4EA
3.5kW
CS-Z35TKEW
● – ● – ●
●
CS-XZ35TKEW
CS-TZ35TKEW
CS-TE35TKEW
CS-E12QD3EAW
CS-E12PB4EA
4.2kW
CS-Z42TKEW
● – ● – ● –
CS-TZ42TKEW
CS-TE42TKEW
5.0kW
CS-Z50TKEW
● – ● – ● –
CS-XZ50TKEW
CS-TZ50TKEW
CS-TE50TKEW
CS-E18RD3EAW
CS-E18RB4EAW
Capacity range of connectable indoor units
3.2kW ~ 6.0kW
3.2kW ~ 6.0kW
3.2kW ~ 7.7kW
Pipe Length
1-room maximum pipe length (m)
20
20
20
Allowable elevation (m)
10
10
10
Total allowable pipe length (m)
30
30
30
Total pipe length for maximum
chargeless length (m)
20 20 20
Additional gas amount over
chargeless length (g/m)
15 15 15
Note*: Above outdoor unit is contains and operates with refrigerant R32 gas.
19
Multi Split Combination Possibility:
o A single outdoor unit enables air conditioning of up to four separate rooms for CU-4Z68TBE
o A single outdoor unit enables air conditioning of up to three separate rooms for CU-3Z68TBE, CU-3Z52TBE.
o A single outdoor unit enables air conditioning of up to three separate rooms for CU-3Z68TBE, CU-3Z52TBE.
CONNECTABLE INDOOR UNIT
CU-4Z68TBE CU-3Z68TBE
CU-3Z52TBE
ROOM
A B C D A
B
C
A
B
C
Wall
1.6kW
CS-MTZ16TKE
CS-MZ16TKE
●
●
●
●
●
●
●
●
●
●
2.0kW
CS-TE20TKEW
CS-TZ20TKEW
CS-XZ20TKEW
CS-TZ20TKEW
CS-XZ20TKEW
CS-Z20TKEW
●
●
●
●
●
●
●
●
●
●
2.5kW
CS-TE25TKEW
CS-TZ25TKEW
CS-XZ25TKEW
CS-TZ25TKEW
CS-XZ25TKEW
CS-Z25TKEW
CS-E9PB4EA
CS-E9PD3EA
CS-E9PD3EA
●
●
●
●
●
●
●
●
●
●
3.5kW
CS-TE35TKEW
CS-TZ35TKEW
CS-XZ35TKEW
CS-TZ35TKEW
CS-XZ35TKEW
CS-Z35TKEW
CS-E12PB4EA
CS-E12QD3EAW
●
●
●
●
●
●
●
●
●
●
4.2kW
CS-TE42TKEW
CS-TZ42TKEW
CS-TZ42TKEW
CS-Z42TKEW
●
●
●
●
●
●
●
●
●
●
5.0kW
CS-TE50TKEW
CS-TZ50TKEW
CS-XZ50TKEW
CS-TZ50TKEW
CS-XZ50TKEW
CS-Z50TKEW
CS-E18RB4EAW
CS-E18RD3EAW
CS-E18RD3EAW
●
●
●
●
●
●
●
●
●
●
6.0kW
CS-TE60TKEW
CS-TZ60TKEW
CS-TZ60TKEW
CS-E21RB4EAW
●
●
●
●
●
●
●
–
–
–
Capacity range of connectable units
From 4.5kW to 11.5kW
From 4.5kW to 11.2kW
From 4.5kW to 9.5kW
Pipe length
1 room maximum pipe length (m)
25
25
25
Allowable elevation (m)
15
15
15
Total allowable pipe length (m)
60
60
50
Total pipe length for maximum
chargeless length (m)
30 30
30
Additional gas amount over
chargeless length (m)
20 20
20
Note: “●” : Available
Remarks for CU-3Z68TBE
1.
The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-3Z68TBE. (Total nominal capacity of indoor units is between
4.5kW to 11.2kW)
1) Two CS-Z25TKEW only. (Total nominal cooling capacity is 5.0kW)
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-3Z68TBE. (Total nominal capacity of indoor units is between
4.5kW to 11.2kW)
1) Two CS-Z25TKEW only. (Total nominal cooling capacity is 5.0kW)
Note*: Above outdoor unit is contains and operates with refrigerant R32 gas.
20
4. Features
Inverter Technology
o Wider output power range
o Energy
o Energy
saving
o Quick
Cooling
o Quick
Heating
o More precise temperature control
Environment Protection
o Non-ozone depletion substances refrigerant (R32)
Long Installation Piping
o Long piping up to 30 meters (2.25 ~ 2.5HP) during single split connection only
Easy to use remote control
Quality Improvement
o Random auto restart after power failure for safety restart operation
o Gas
o Gas
leakage
protection
o Prevent compressor reverse cycle
o Inner protector to protect compressor
o Noise prevention during soft dry operation
o Inner protector to protect compressor
o Noise prevention during soft dry operation
Operation Improvement
o Quiet mode to reduce the indoor unit operating sound
o Powerful mode to reach the desired room temperature quickly
o 24-hour timer setting
o Powerful mode to reach the desired room temperature quickly
o 24-hour timer setting
Serviceability Feature
o Breakdown Self Diagnosis function
Click on the first or last page to see other CS-TZ60TKEW / CS-TZ71TKEW / CU-TZ60TKE / CU-TZ71TKE service manuals if exist.