Date

Panasonic CS-TZ20TKEW / CS-TZ25TKEW / CS-TZ35TKEW / CS-TZ42TKEW / CS-MTZ16TKE / CU-TZ20TKE / CU-TZ25TKE / CU-TZ35TKE / CU-TZ42TKE Service Manual ▷ View online

17 
  Multi Split Combination Possibility: 
o  A single outdoor unit enables air conditioning of up to two separate rooms for CU-2RE15SBE,  
CU-2RE18SBE. 
o  A single outdoor unit enables air conditioning of up to three separate rooms for CU-3RE18SBE. 
 
CONNECTABLE INDOOR UNIT 
OUTDOOR UNIT 
CU-2RE15SBE* CU-2RE18SBE* 
CU-3RE18SBE* 
ROOM 
TYPE 
A B A B A B C 
Wall
 
1.6kW CS-MTZ16TKE 
● 
● 
● 
● 
● 
● 
● 
2.0kW CS-TZ20TKEW 
● 
● 
● 
● 
● 
● 
● 
2.5kW CS-TZ25TKEW 
● 
● 
● 
● 
● 
● 
● 
3.5kW CS-TZ35TKEW 
● 
● 
● 
● 
● 
● 
● 
4.2kW CS-TZ42TKEW 
– 
– 
● 
● 
● 
● 
● 
5.0kW CS-TZ50TKEW 
– 
– 
● 
● 
● 
● 
● 
Capacity range of 
connectable indoor units 
From 4.0kW to 5.7kW 
From 4.0kW to 7.5kW 
From 4.5kW to 9.0kW 
Pipe length 
1 room maximum pipe length (m) 
20 
20 
25 
Allowable elevation (m) 
10 
10 
15 
Total allowable pipe length (m) 
30 
30 
50 
Total pipe length for maximum 
chargeless length (m) 
20 20 
30 
Additional gas amount over 
chargeless length (g/m) 
15 15 
20 
Note: “●” : Available 
Remarks for CU-2RE15SBE / CU-2RE18SBE 
1.  The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable capacity range of  
indoor unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-2RE15SBE. (Total nominal capacity of indoor units is between 
4.0kW to 5.7kW) 
1) Two CS-TZ20TKEW only. (Total nominal cooling capacity is 4.0kW) 
Remarks for CU-3RE18SBE 
1.  The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable capacity range of  
indoor unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-3RE18SBE. (Total nominal capacity of indoor units is between 
4.5kW to 9.0kW) 
1) Two CS-TZ25TKEW only. (Total nominal cooling capacity is 5.0kW) 
 
Note*: Above outdoor unit is contains and operates with refrigerant R410A gas. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
18 
  Multi Split Combination Possibility: 
o  A single outdoor unit enables air conditioning of up to two separate rooms for CU-2E12SBE, CU-2E15SBE, 
CU-2E18SBE. 
o  A single outdoor unit enables air conditioning of up to three separate rooms for CU-3E23SBE. 
 
CONNECTABLE INDOOR UNIT CU-2E12SBE* CU-2E15SBE* CU-2E18SBE* 
CU-3E23SBE* 
ROOM 
A B A B A B A B C 
Wall
 
1.6kW CS-MTZ16TKE  ● 
● 
● 
● 
● 
● 
● 
● 
● 
2.0kW CS-TZ20TKEW  ● 
● 
● 
● 
● 
● 
● 
● 
● 
2.5kW CS-TZ25TKEW  ● 
● 
● 
● 
● 
● 
● 
● 
● 
3.5kW CS-TZ35TKEW  ● 
● 
● 
● 
● 
● 
● 
● 
● 
4.2kW 
CS-TZ42TKEW – – – – ● 
● 
● 
● 
● 
5.0kW 
CS-TZ50TKEW – – – – ● 
● 
● 
● 
● 
6.0kW 
CS-TZ60TKEW – – – – – – ● 
● 
● 
Capacity range of connectable units 
From 3.2kW to 5.7kW From 3.2kW to 5.7kW From 3.2kW to 7.5kW
From 4.5kW to 11.0kW 
Pipe length 
1 room maximum pipe length (m) 
20 
20 
20 
25 
Allowable elevation (m) 
10 
10 
10 
15 
Total allowable pipe length (m) 
30 
30 
30 
60 
Total pipe length for maximum 
chargeless length (m) 
20 20 20 
30 
Additional gas amount over 
chargeless length (g/m) 
15 15 15 
20 
Note: “●” : Available 
Remarks for CU-2E12SBE / CU-2E15SBE / CU-2E18SBE 
1.  The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor 
unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-2E15SBE. (Total nominal capacity of indoor units is between 
3.2kW to 5.7kW) 
1) Two CS-TZ20TKEW only. (Total nominal cooling capacity is 4.0kW) 
Remarks for CU-3E23SBE 
1.  The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor 
unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-3E23SBE. (Total nominal capacity of indoor units is between 
4.5kW to 11.0kW) 
1) Two CS-TZ25TKEW only. (Total nominal cooling capacity is 5.0kW) 
 
Note*: Above outdoor unit is contains and operates with refrigerant R410A gas. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
19 
  Multi Split Combination Possibility: 
o  A single outdoor unit enables air conditioning of up to three separate rooms for CU-3E18PBE. 
o  A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E23PBE, CU-4E27PBE. 
o  A single outdoor unit enables air conditioning of up to five separate rooms for CU-5E34PBE. 
 
CONNECTABLE INDOOR UNIT CU-3E18PBE*  CU-4E23PBE* 
CU-4E27PBE* 
CU-5E34PBE* 
ROOM 
A  B  C  A B C D A B C D A B C D E 
Wall
 
1.6kW CS-MTZ16TKE  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
2.0kW CS-TZ20TKEW  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
2.5kW CS-TZ25TKEW  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
3.5kW CS-TZ35TKEW  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
4.2kW CS-TZ42TKEW  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
5.0kW CS-TZ50TKEW  ● 
● 
● 
● 
● 
● 
● 
 
 
● 
● 
 
 
● 
● 
● 
6.0kW CS-TZ60TKEW  – – – ● 
● 
● 
● 
 
 
● 
● 
 
 
● 
● 
● 
7.1kW  CS-TZ71TKEW  –  –  –  – – – – ●
 
 
● 
● 
 
 
● 
● 
● 
Capacity range of connectable units  From 4.5kW to 9.0kW From 4.5kW to 11.0kW
From 4.5kW to 13.6kW 
From 4.5kW to 17.5kW 
Pipe length 
1 room maximum pipe length (m)
25 
25 
25 
25 
Allowable elevation (m) 
15 
15 
15 
15 
Total allowable pipe length (m) 
50 
60 
70 
80 
Total pipe length for maximum 
chargeless length (m) 
30 30  45 
45 
Additional gas amount over 
chargeless length (g/m) 
20 20  20 
20 
Note: “●” : Available 
Remarks for CU-3E18PBE / CU-4E23PBE / CU-4E27PBE / CU-5E34PBE 
1. 
The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-4E27PBE. (Total nominal capacity of indoor units is between 
4.5kW to 13.6kW) 
1) Two CS-TZ25TKEW only. (Total nominal cooling capacity is 5.0kW) 
 
Note*: Above outdoor unit is contains and operates with refrigerant R410A gas. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
20 
4. Features 
 
  Inverter Technology 
o  Wider output power range 
o Energy 
saving 
o Quick 
Cooling 
o Quick 
Heating 
o  More precise temperature control 
 
  Environment Protection 
o  Non-ozone depletion substances refrigerant (R32) 
 
  Long Installation Piping 
o  Long piping up to 15 meters (3/4 ~ 1.75HP) and 20 meters (2.0HP) during single split connection only 
 
  Easy to use remote control 
 
  Quality Improvement 
o  Random auto restart after power failure for safety restart operation 
o Gas 
leakage 
protection 
o  Prevent compressor reverse cycle 
o  Inner protector to protect compressor 
o  Noise prevention during soft dry operation 
 
  Operation Improvement 
o  Quiet mode to reduce the indoor unit operating sound 
o  Powerful mode to reach the desired room temperature quickly 
o  24-hour timer setting 
 
  Serviceability Feature 
o  Breakdown Self Diagnosis function 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127