Panasonic CS-PA7KKD / CS-PA9KKD / CS-PA12KKD / CS-PA16KKD / CU-PA7KKD / CU-PA9KKD / CU-PA12KKD / CU-PA16KKD Service Manual ▷ View online
6
Speed Hi
(HEATING)
rpm
840
840
Moisture Removal
L/h (Pt/h)
1.3 (2.2)
1.5 (2.6)-1.5(2.6)
Lo m
3
/min (ft
3
/m)
7.8 (274)
8.1 (213)
Me m
3
/min (ft
3
/m)
9.2 (323)
9.5 (333)
Indoor Airflow
(COOLING)
Hi m
3
/min (ft
3
/m)
10.8 (380)
10.8 (380)
Lo m
3
/min (ft
3
/m)
7.9 (277)
8.7 (306)
Me m
3
/min (ft
3
/m)
9.4 (330)
10.3 (364)
Indoor Airflow
(HEATING)
Hi m
3
/min (ft
3
/m)
11.0 (387)
11.0 (387)
Hi (COOLING) m
3
/min (ft
3
/m)
26.8 (948)
26.8 (948)
Outdoor
Airflow
Hi (HEATING) m
3
/min (ft
3
/m)
26.8 (948)
27.2 (960)
Control Device
Capillary Tube
Capillary Tube
Refrigerant Oil
cm
3
ATMOS M60 or SUNISO 4GDID
(290)
ATMOS NM56M or SUNISO 4GDID
(350)
Refrigeration
Cycle
Refrigerant
Type
g (oz)
R22, 580 (20.3)
R22, 850 (29.7)
Height(I/D /
O/D)
mm (inch)
290 (11-15/32)
530(20-7/8)
290 (11-15/32)
530 (20-7/8)
Width (I/D /
O/D)
mm (inch)
848 (33-13/32)
650(25-19/32)
848 (33-13/32)
650 (25-19/32)
Dimension
Depth (I/D /
O/D)
mm (inch)
204 (8-1/32)
230 (9-1/16)
204 (8-1/32)
230 (9-1/16)
Weight
Net (I/D / O/D)
kg (lb)
9.0 (20)
21 (46)
9.0 (20)
25 (55)
Pipe Diameter (Liquid /
Gas)
mm (inch)
6.35 (1/4) / 9.52 (3/8)
6.35 (1/4) / 9.52 (3/8)
Standard length
m (ft)
5.0 (16.4)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 7 (23.0)
3 (9.8) ~ 7 (23.0)
I/D & O/D Height different
m (ft)
5.0 (16.4)
5.0 (16.4)
Additional Gas Amount
g/m (oz/ft)
-
-
Piping
Length for Additional Gas
m (ft)
-
-
Inner Diameter
mm
16
16
Drain Hose
Length mm
500
500
Fin Material
Pre coated
Pre coated
Fin Type
Slit Fin
Slit Fin
Row x Stage x
FPI
2 x 15 x 18
2 x 15 x 18
Indoor Heat
Exchanger
Size (W x H x L)
mm
610 x 315 x 25.4
610 x 315 x 25.4
Fin Material
Pre coated
Pre coated
Fin Type
Slit Fin
Slit Fin
Row x Stage x
FPI
1 x 24 x 21
1 x 24 x 21
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
18.19 x 504.0 x 563.9
18.19 x 504.0 x 563.9
Material
P.P.HONEY COMB
P.P.HONEY COMB
Air Filter
Type
One-touch
One-touch
Power Supply
Indoor
Indoor
Power Supply Cord
A
Nil (10A)
Nil (10A)
Thermostat
-
-
Protection Device
-
-
COOLING HEATING COOLING
HEATING
Temperature (℃)
DRY
BULB
WET
BULB
DRY
BULB
WET
BULB
DRY
BULB
WET
BULB
DRY
BULB
WET
BULB
Maximum 32 23 30 - 32 23 30
-
Indoor Operation Range
Minimum 16 11 16 - 16 11 16
-
Maximum 43 26 24 18 43 26 24 18
Outdoor Operation Range
Minimum 16 11 -5 -6 16 11
-5
-6
1.
Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
Heating capacities are based on indoor temperature of 20°C DRY BULB (68°F DRY BULB), and outdoor air temperature of 7°C DRY BULB
(95°F DRY BULB), 6°C WET BULB (75.2°F WET BULB)
(95°F DRY BULB), 6°C WET BULB (75.2°F WET BULB)
7
Indoor CS-PA12KKD
CS-PA16KKD
Model
Outdoor CU-PA12KKD
CU-PA16KKD
Performance Test Condition
JIS
JIS
Phase, Hz
Single, 50
Single, 50
Power Supply
V
220 240 220 240
kW
3.600 3.650 4.600 4.600
BTU/h
12270 12440 15680 15680
Capacity
kJ/h
3090 3130 3950 3950
Running
Current
A
6.00 5.70 8.40 8.00
Input
Power
W
1290 1330 1790 1840
W/W
2.79 2.74 2.56 2.50
EER
Btu/hW
9.51 9.35 8.75 8.52
Power
Factor
%
97 96 96 95
Indoor Noise (H / L / QLo)
dB-A
39 / 33 / -
42 / 39 / -
Cooling
Outdoor Noise (H / L)
dB-A
49 / -
50 / -
kW
4.000 4.050 5.300 5.350
BTU/h
13640 13810 18070 18240
Capacity
kJ/h
3430 3480 4550 4590
Running
Current
A
5.20 5.00 8.50 8.10
Input
Power
W
1100 1130 1840 1890
W/W
3.63 3.58 2.88 2.83
EER
Btu/hW 12.40
12.22
9.82
9.65
Power
Factor
%
97 94 98 97
Indoor Noise (H / L / QLo)
dB-A
39 / 32 / -
40 / 37 / -
Heating
Outdoor Noise (H / L)
dB-A
50 / -
52 / -
Max Current (A) / Max Input Power (W)
7.80 / 1.540k
10.70 / 2.200k
Starting Current (A)
23.6
38.9
Type
Hermetic Motor
Hermetic Motor
Motor Type
Induction (2 poles)
Induction (2 poles)
Compressor
Output Power
W
1100
2160
Type
Cross-flow fan
Cross-flow fan
Material
AS
AS
Motor Type
AC (4-poles)
AC (4-poles)
Input Power
W
45.7
45.7
Output Power
W
18
18
Lo rpm
920
1000
Me rpm
1000
1090
Speed
(COOLING)
Hi rpm
1090
1180
Lo rpm
850
980
Me rpm
980
1060
Indoor Fan
Speed
(HEATING)
Hi rpm
1140
1150
Type
Propeller
Propeller
Material
PP
PP
Motor Type
PSC (6 poles)
PSC (6 poles)
Input Power
W
63.4
72
Output Power
W
28
28
Speed Hi
(COOLING)
rpm
870
920
Outdoo
r Fa
n
Speed Hi
(HEATING)
rpm
890
950
8
Moisture Removal
L/h (Pt/h)
2.1 (3.6)-2.1 (3.6)
2.6 (4.5)-2.6 (4.5)
Lo m
3
/min (ft
3
/m)
9.9 (332)
10.3 (364)
Me m
3
/min (ft
3
/m)
10.8 (381)
11.3 (397)
Indoor Airflow
(COOLING)
Hi m
3
/min (ft
3
/m)
11.8 (416)
12.2 (430)
Lo m
3
/min (ft
3
/m)
8.9 (315)
10.6 (372)
Me m
3
/min (ft
3
/m)
10.3 (364)
11.4 (403)
Indoor Airflow
(HEATING)
Hi m
3
/min (ft
3
/m)
12.0 (423)
12.4 (437)
Outdoor
Airflow
Hi (COOLING)
m
3
/min (ft
3
/m)
29.0(1026)
34.4 (1217)
Outdoor
Airflow
Hi (HEATING)
m
3
/min (ft
3
/m)
29.5 (1041)
35.0 (1235)
Control Device
Capillary tube
Capillary tube
Refrigerant Oil
cm
3
ATMOS NM56M OR SUNISO 4GDID (410)
ATMOS M60M OR SUNISO 4GDID (650)
Refrigeration
Cycle
Refrigerant Type
g (oz)
R22, 920 (32.2)
R22, 890 (31.1)
Height(I/D / O/D)
mm (inch)
290 (11-15/32)
540 (21-1/4)
290 (11-15/32)
540 (21-1/4)
Width (I/D / O/D)
mm (inch)
848 (33-13/32)
780 (30-23/32)
848 (33-13/32)
780 (30-23/32)
Dimension
Depth (I/D / O/D)
mm (inch)
204 (8-1/32)
289 (11-3/8)
204 (8-1/32)
289 (11-3/8)
Weight
Net (I/D / O/D)
kg (lb)
9.0 (20)
34 (75)
9.0 (20)
40 (88)
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 12.7 (1/2)
6.35 (1/4) / 12.7 (1/2)
Standard length
m (ft)
5.0 (16.4)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 10 (32.8)
3 (9.8) ~ 10 (32.8)
I/D & O/D Height different
m (ft)
5.0 (16.4)
5.0 (16.4)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
20 (0.2)
Piping
Length for Additional Gas
m (ft)
7.0 (23.0)
7.0 (23.0)
Inner Diameter
mm
16
16
Drain Hose
Length mm
500
500
Fin Material
Pre coated
Pre coated
Fin Type
Slit fin
Slit fin
Row x Stage x FPI
2 x 15 x 18
2 x 15 x 18
Indoor Heat
Exchanger
Size (W x H x L)
mm
610 x 315 x 25.4
610 x 315 x 25.4
Fin Material
Pre coated
Pre coated
Fin Type
Slit fin
Slit fin
Row x Stage x FPI
2 x 24 x 18
2 x 20 x 19
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
36.38 x 504.0 x 708.7
680.2
44 x 508 x 706.3
669.9
Material
P.P,HONEY COMB
P.P,HONEY COMB
Air Filter
Type
One-touch
One-touch
Power Supply
Indoor
Indoor
Power Supply Cord
A
Nil (10A)
Nil (10A)
Thermostat
-
-
Protection Device
-
-
COOLING HEATING COOLING HEATING
Temperature (℃)
DRY BULB WET BULB DRY BULB WET BULB DRY BULB WET BULB DRY BULB WET BULB
Maximum
32 23 30 - 32 23 30 -
Indoor Operation Range
Minimum
16 11 16 - 16 11 16 -
Maximum
43 26 24 18 43 26 24 18
Outdoor Operation Range
Minimum
16 11 -5 -6 16 11 -5 -6
1.
Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
Heating capacities are based on indoor temperature of 20°C DRY BULB (68°F DRY BULB) and outdoor air temperature of 7°C DRY BULB
(95°F DRY BULB), 6°C WET BULB (75.2°F WET BULB)
(95°F DRY BULB), 6°C WET BULB (75.2°F WET BULB)
9
3. Features
z Easy to use remote control
z Random auto restart after power failure for safety restart operation
z Gas
leakage
protection
z Prevent compressor reverse cycle
z 12-hour timer setting
Click on the first or last page to see other CS-PA7KKD / CS-PA9KKD / CS-PA12KKD / CS-PA16KKD / CU-PA7KKD / CU-PA9KKD / CU-PA12KKD / CU-PA16KKD service manuals if exist.