DOWNLOAD Panasonic CS-PA7KKD / CS-PA9KKD / CS-PA12KKD / CS-PA16KKD / CU-PA7KKD / CU-PA9KKD / CU-PA12KKD / CU-PA16KKD Service Manual ↓ Size: 4.09 MB | Pages: 39 in PDF or view online for FREE

Model
CS-PA7KKD CS-PA9KKD CS-PA12KKD CS-PA16KKD CU-PA7KKD CU-PA9KKD CU-PA12KKD CU-PA16KKD
Pages
39
Size
4.09 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-pa7kkd-cs-pa9kkd-cs-pa12kkd-cs-pa16kkd-cu-pa7kk.pdf
Date

Panasonic CS-PA7KKD / CS-PA9KKD / CS-PA12KKD / CS-PA16KKD / CU-PA7KKD / CU-PA9KKD / CU-PA12KKD / CU-PA16KKD Service Manual ▷ View online

13 
6. Refrigeration Cycle Diagram 
  
 
     
              
 
 
Evaporator 
Condenser 
14 
7. Block Diagram 
 
 
 
15 
8. Wiring Connection Diagram 
 
 
 
 
16 
9. Installation Instruction 
9.1  Select The Best Location  
9.1.1 Indoor 
Unit 
•  There should not be any heat source or steam near the 
unit.  
•  There should not be any obstacles blocking the air 
circulation. 
•  A place where air circulation in the room is good. 
•  A place where drainage can be easily done. 
•  A place where noise prevention is taken into 
consideration. 
•  Do not install the unit near the door way.  
•  Ensure the spaces indicated by arrows from the wall, 
ceiling, fence or other obstacles. 
•  Recommended installation height for indoor unit shall be 
at least 2.5m. 
9.1.2 Outdoor 
Unit 
•  If an awning is built over the unit to prevent direct 
sunlight or rain, be careful that heat radiation from the 
condenser is not obstructed. 
•  There should not be any animal or plant which could be 
affected by hot air discharged. 
•  Keep the spaces indicated by arrows from wall, ceiling, 
fence or other obstacles. 
•  Do not place any obstacles which may cause a short 
circuit of the discharged air. 
•  If piping length is over the rated length, additional 
refrigerant should be added as shown in the table below: 
 
 
 
 
 
 
 
 
Example: For PA12KKD 
If the unit is installed at a 10m distance, the quantity  
of additional refrigerant should be 60 g. 
…… (10-7) m x 20g/m = 60 g 
 
 
 
Piping size 
Model 
Gas Liquid 
Rated 
Length 
(m) 
Max 
Elevati
on (m) 
Min 
Piping 
Length 
(m) 
Max 
Piping 
Length 
(m) 
Additional 
Refrigera
nt (g/m) 
CS/CU-PA7KKD 
3/8” 
1/4" 
-  5 3 
7 - 
CS/CU-PA9KKD 
3/8” 
1/4” 
-  5 3 
7 - 
CS/CU-PA12KKD 
1/2” 
1/4” 
7 5 3 
10 
20 
CS/CU-PA16KKD 
1/2” 
1/4” 
7 5 3 
10 
20 
8.1.3 Indoor/Outdoor Unit
Note: 
*For optimum performance,  at least two sides 
should be 1m or more away from obstacles. 
 
*This illustration is for explanation purposes 
only. The indoor unit will actually face a 
different way. 
Page of 39
Display

Click on the first or last page to see other CS-PA7KKD / CS-PA9KKD / CS-PA12KKD / CS-PA16KKD / CU-PA7KKD / CU-PA9KKD / CU-PA12KKD / CU-PA16KKD service manuals if exist.