CAUTION 
11. 
Labelling 
 
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. 
 
The label shall be dated and signed. 
 
Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. 
12. 
Recovery 
 
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all 
refrigerants are removed safely. 
 
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. 
 
Ensure that the correct number of cylinders for holding the total system charge are available. 
 
All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the 
recovery of refrigerant). 
 
Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. 
 
Recovery cylinders are evacuated and, if possible, cooled before recovery occurs. 
 
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall 
be suitable for the recovery of flammable refrigerants. 
 
In addition, a set of calibrated weighing scales shall be available and in good working order. 
 
Hoses shall be complete with leak-free disconnect couplings and in good condition. 
 
Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any 
associated electrical components are sealed to prevent ignition in the event of a refrigerant release. 
Consult manufacturer if in doubt. 
 
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste 
Transfer Note arranged. 
 
Do not mix refrigerants in recovery units and especially not in cylinders. 
 
If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain 
that flammable refrigerant does not remain within the lubricant. 
 
The evacuation process shall be carried out prior to returning the compressor to the suppliers. 
 
Only electric heating to the compressor body shall be employed to accelerate this process. 
 
When oil is drained from a system, it shall be carried out safely. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10 
3. Specifications 
Model Indoor 
CS-MZ20UD3EA 
Performance Test Condition 
EUROVENT 
Power Supply 
Phase, Hz 
Single, 50 
V 230 
 Min. 
Mid. 
Max. 
Cooling 
Capacity 
kW 1.80  2.00  2.90 
BTU/h 6140 
6820 
9890 
Running Current 
– 
2.70 
– 
Input Power 
340 
550 
860 
Annual Consumption 
kWh 
– 
275 
– 
EER W/W 
5.29  3.64  3.37 
Indoor Noise (H / L / QLo) 
dB-A 
34 / 29 / 26 
Power Level dB 
50 / – / – 
Heating
 
Capacity 
kW 1.20  3.20  4.10 
BTU/h 4090 
10900  14000 
Running Current 
– 
4.10 
– 
Input Power 
300 
840 
1.33k 
COP W/W 
4.00  3.81  3.08 
Indoor Noise (H / L / QLo) 
dB-A 
36 / 29 / 26 
Power Level dB 
52 / – / – 
Indoor Fan
 
Type  
SIROCCO 
Material  
GFZ010A 
GF20 
Motor Type 
 
DC / Transistor (8-poles) 
Input Power 
– 
Output Power 
51 
Speed 
QLo 
Cool rpm 
800 
Heat rpm 
790 
Lo 
Cool rpm 
880 
Heat rpm 
860 
Me 
Cool rpm 
970 
Heat rpm 
960 
Hi 
Cool rpm 
1070 
Heat rpm 
1070 
SHi 
Cool rpm 
1120 
Heat rpm 
1120 
Moisture Removal 
L/h (Pt/h) 
1.3 (2.7) 
Indoor 
Airflow 
QLo 
Cool m
3
/min (ft
3
/min.) 7.3 
(260) 
Heat m
3
/min (ft
3
/min.) 7.2 
(250) 
Lo 
Cool m
3
/min (ft
3
/min.) 8.2 
(290) 
Heat m
3
/min (ft
3
/min.) 7.9 
(280) 
Me 
Cool m
3
/min (ft
3
/min.) 9.0 
(320) 
Heat m
3
/min (ft
3
/min.) 8.9 
(310) 
Hi 
Cool m
3
/min (ft
3
/min.) 10.1 
(355) 
Heat m
3
/min (ft
3
/min.) 10.1 
(355) 
SHi 
Cool m
3
/min (ft
3
/min.) 10.5 
(370) 
Heat m
3
/min (ft
3
/min.) 10.5 
(370) 
Dimension 
Height (I/D) 
mm (inch) 
200 (7-7/8) 
Width (I/D) 
mm (inch) 
750 (29-17/32) 
Depth (I/D) 
mm (inch) 
640 (25-7/32) 
11 
Model Indoor 
CS-MZ20UD3EA 
Weight 
Net (I/D) 
kg (lb) 
19 (42) 
Piping 
Pipe Diameter  
(Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
Drain Hose 
Inner Diameter 
mm  
16 
Length mm 
117.5 
Indoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Row × Stage × FPI 
 
3 × 12 × 18 
Size (W × H × L) 
mm 
590 × 282 × 38.1 
Air Filter 
Material  
– 
Type  
– 
Power Supply 
 
Outdoor 
Power Supply Cord 
Nil 
Thermostat  
Electronic 
Contol 
Protection Device 
 
Electronic Contol 
 
Dry Bulb 
Wet Bulb 
Indoor 
Operation 
Range 
Cooling 
Maximum °C 
32 
23 
Minimum °C 
16 
11 
Heating 
Maximum °C 
30 
– 
Minimum °C 
16 
– 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb). 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F 
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb). 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C. 
5. 
Standby power consumption ≤10.0w (when switched OFF by remote control, except under self protection control). 
6. 
Specifications are subjected to change without prior notice for further improvement. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
12 
  Multi Split Combination Possibility: 
o  A single outdoor unit enables air conditioning of up to two separate rooms for CU-2Z35TBE, CU-2Z41TBE, 
CU-2Z50TBE. 
o  A single outdoor unit enables air conditioning of up to three separate rooms for CU-3Z68TBE, CU-3Z52TBE. 
 
CONNECTABLE INDOOR UNIT  CU-2Z35TBE CU-2Z41TBE CU-2Z50TBE 
CU-3Z68TBE 
CU-3Z52TBE 
ROOM 
A B A B A B A B C A B C 
Wall
 
2.0kW CS-MZ20UD3EA  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
2.5kW CS-Z25UD3EAW  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
3.5kW CS-Z35UD3EAW  ● – ● – ● 
● 
● 
● 
● 
● 
● – 
5.0kW CS-Z50UD3EAW – – – – ● – ● 
● – ● – – 
6.0kW CS-Z60UD3EAW – – – – – – ● – – – – – 
Capacity range of connectable units 
From 3.2kW to 
6.0kW 
From 3.2kW to 
6.0kW 
From 3.2kW to 
7.7kW 
From 4.5kW to 11.2kW 
From 4.5kW to 9.5kW 
Pipe length 
1 room maximum pipe length (m) 
20 
20 
20 
25 
25 
Allowable elevation (m) 
10 
10 
10 
15 
15 
Total allowable pipe length (m) 
30 
30 
30 
60 
50 
Total pipe length for maximum 
chargeless length (m) 
20 20 20 
30 
30 
Additional gas amount over 
chargeless length (g/m) 
15 15 15 
20 
20 
Note: “●” : Available 
Remarks for CU-2Z35TBE / CU-2Z41TBE / CU-2Z50TBE 
1.  The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor 
unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-2Z41TBE. (Total nominal capacity of indoor units is between 
3.2kW to 6.0kW) 
1) Two CS-MZ20UD3EA only. (Total nominal cooling capacity is 4.0kW) 
Remarks for CU-3Z68TBE / CU-3Z52TBE 
1.  The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor 
unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-3Z68TBE. (Total nominal capacity of indoor units is between 
4.5kW to 11.2kW) 
1) Two CS-Z25UD3EAW only. (Total nominal cooling capacity is 5.0kW) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 103
Display

Click on the first or last page to see other CS-MZ20UD3EA service manuals if exist.