15 
  Multi Split Combination Possibility: 
o  A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E23PBE, CU-4E27PBE. 
o  A single outdoor unit enables air conditioning of up to five separate rooms for CU-5E34PBE. 
 
CONNECTABLE INDOOR UNIT CU-4E23PBE* 
CU-4E27PBE* 
CU-5E34PBE* 
ROOM 
A B C D A B C D A B C D E 
 
2.0kW CS-MZ20UD3EA  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
2.5kW CS-Z25UD3EAW  ● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
● 
3.2kW CS-Z35UD3EAW  ● 
● 
● – ● 
● 
● 
● 
● 
● 
● 
● 
● 
5.0kW CS-Z50UD3EAW  ● 
● – – ●
– – ●
 
 
● – – 
6.0kW CS-Z60UD3EAW  ● – – – ●
– – ●
 
 
– – – 
Capacity range of connectable units 
From 4.5kW to 11.0kW 
From 4.5kW to 13.6kW 
From 4.5kW to 17.5kW 
Pipe length 
1 room maximum pipe length (m) 
25 
25 
25 
Allowable elevation (m) 
15 
15 
15 
Total allowable pipe length (m) 
60 
70 
80 
Total pipe length for maximum 
chargeless length (m) 
30 45 
45 
Additional gas amount over 
chargeless length (g/m) 
20 20 
20 
Note: “●” : Available 
Remarks for CU-4E23PBE / CU-4E27PBE / CU-5E34PBE 
1. 
The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above) 
Example: The indoor units’ combination below is possible to connect to CU-4E27PBE. (Total nominal capacity of indoor units is between 
4.5kW to 13.6kW) 
1) Two CS-Z25UD3EAW only. (Total nominal cooling capacity is 5.0kW) 
 
Note*: Above outdoor unit is contains and operates with refrigerant R410A gas. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
16 
4. Features 
  Inverter Technology 
o  Wider output power range 
o Energy 
saving 
o Quick 
Cooling 
o Quick 
Heating 
o  More precise temperature control 
 
  Environment Protection 
o  Non-ozone depletion substances refrigerant (R32) 
 
  Easy to use remote control 
 
  Quality Improvement 
o  Random auto restart after power failure for safety restart operation 
o Gas 
leakage 
protection 
o  Prevent compressor reverse cycle 
o  Inner protector to protect compressor 
o  Noise prevention during soft dry operation 
 
  Operation Improvement 
o  Quiet mode to reduce the indoor unit operating sound 
o  Powerful mode to reach the desired room temperature quickly 
o  24-hour timer setting 
 
  Serviceability Feature 
o  Breakdown Self Diagnosis function 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
17 
5. Location of Controls and Components 
5.1 Indoor 
Unit 
 
 
5.2 Remote 
Control 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Air inlet
Air outlet
OFF / ON
TEMP
TIMER/CLOCK
MODE
QUIET/
POWERFUL
FAN SPEED
MODE
CHECK
RESET
AIR SWING
OFF/ON
CANCEL
CLOCK
SET
SELECT
UP
DOWN
AC
RC
Operation Mode Selection
Indicator
OFF Indicator
Timer/Clock Setting Display
Check Button
Fan Speed Display
Temperature Setting Display
Powerful Operation Indicator
Quiet Operation Indicator
OFF/ON Button
Operation Mode Button
Temperature Setting Button
Fan Speed Button
Quiet/Powerful Operation Button
Remote Control Reset Button
Air Conditioner Reset Button
System Error Display
Operation LED
Timer Setting Button Group
18 
6. Dimensions 
6.1 Indoor 
Unit 
 
 
 
 
 
(AIR OUTLET DUCT FLANGE)
692
145
(AIR OUTLET
 DUCT
 FLANGE)
96
27
160 × 4 = 640
5 - Ø 3.1 HOLE
26
750
824
904
640
564
194
AIR FILTER
(AIR INLET)
126
680
(AIR INLET)
23
132
220
220
132
14
14
23
155
120
23
40
23
200
150
DRAIN PORT
(UPPER & LOWER)
120
33
80
143
44
238
81
WATER
INLET
28
84
30
10
2 - Ø 3.1 HOLE
<Remote control transmitter>
<Remote Control>
<Top View>
<Side View>
<Side View>
<Front View>
<Back View>
15.5
Panasonic
116
120
Unit: mm
Page of 103
Display

Click on the first or last page to see other CS-MZ20UD3EA service manuals if exist.