65
15.4.7. H23 (Indoor Pipe Temperature Sensor Abnormality)
Malfunction Decision Conditions
During startup and operation of cooling and heating, the temperatures detected by the indoor heat exchanger temperature
sensor are used to determine sensor errors.
Malfunction Caused
• Faulty connector connection.
• Faulty sensor.
• Faulty  PCB.
Troubleshooting
66
15.4.8. H25 (e-ion Air Purifying System Abnormal)
Malfunction Decision Conditions
During standby of cooling and heating operation, e-ion breakdown occurs and air conditioner stops operation.
Malfunction Caused
• Faulty indoor main PCB.
• Faulty indoor e-ion power module.
Troubleshooting
67
15.4.9. H27 (Outdoor Air Temperature Sensor Abnormality)
Malfunction Decision Conditions
During startup and operation of cooling and heating, the temperatures detected by the outdoor air temperature sensor are used
to determine sensor errors.
Malfunction Caused
• Faulty connector connection.
• Faulty sensor.
• Faulty  PCB.
Troubleshooting
68
15.4.10. H28 (Outdoor Pipe Temperature Sensor Abnormality)
Malfunction Decision Conditions
During startup and operation of cooling and heating, the temperatures detected by the outdoor pipe temperature sensor are
used to determine sensor errors.
Malfunction Caused
• Faulty connector connection.
• Faulty sensor.
• Faulty PCB.
Troubleshooting