Panasonic CS-HE7QKD / CS-HE9QKD / CS-HE12QKD / CS-HE18QKD / CU-HE7QKD / CU-HE9QKD / CU-HE12QKD / CU-HE18QKD Service Manual ▷ View online
13
Indoor CS-HE12QKD
Model
Outdoor CU-HE12QKD
Inner Diameter
mm
16.7
Drain Hose
Length mm
650
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row × Stage × FPI
2 × 17 × 21
Indoor Heat
Exchanger
Size (W × H × L)
mm
636.5 × 357 × 25.4
Fin Material
Aluminium (Blue Coated)
Fin Type
Corrugated Fin
Row × Stage × FPI
2 × 28 × 17
Outdoor Heat
Exchanger
Size (W × H × L)
mm
36.38 × 588 × 781.3:752.7
Material
Polypropelene
Air Filter
Type
One-touch
Power Supply
Indoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Maximum °C
32
23
Cooling
Minimum °C
16
11
Maximum °C
30
—
Indoor
Operation
Range
Heating
Minimum °C
16
—
Maximum °C
43
26
Cooling
Minimum °C
-10
—
Maximum °C
24
18
Outdoor
Operation
Range
Heating
Minimum °C
-15
-16
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for further improvement.
14
Indoor CS-HE18QKD
Model
Outdoor CU-HE18QKD
Performance Test Condition
JIS
Phase, Hz
Single, 50
Power Supply
V 220
230
Min. Mid. Max. Min. Mid. Max.
kW 0.98 5.00 6.00 0.98 5.00 6.00
BTU/h 3340 17100 20500 3340 17100 20500
Capacity
Kcal/h 840 4300 5160 840 4300 5160
Running
Current
A
— 6.8 — — 6.4 —
Input
Power
W
280 1.44k 1.99k 280 1.44k 1.99k
Annual
Consumption kWh — 720 — — 720 —
W/W 3.50 3.47 3.02 3.50 3.47 3.02
BTU/hW 11.93 11.88 10.30 11.93 11.88 10.30
EER
Kcal/hW 3.00 2.99 2.59 3.00 2.99 2.59
Power
Factor
% — 96 — — 98 —
dB-A
44 / 37 / 34
44 / 37 / 34
Indoor Noise (H / L / QLo)
Power Level dB
60 / - / -
60 / - / -
dB-A
47 / - / -
47 / - / -
Cooling
Outdoor Noise (H / L / QLo)
Power Level dB
61 / - / -
61 / - / -
kW 0.98 5.80 8.00 0.98 5.80 8.00
BTU/h 3340 19800 27300 3340 19800 27300
Capacity
Kcal/h 840 4990 6880 840 4990 6880
Running
Current
A
— 7.1 — — 6.8 —
Input
Power
W
340 1.52k 2.57k 340 1.52k 2.57k
W/W 2.88 3.82 3.11 2.88 3.82 3.11
BTU/hW 9.82 13.03 10.62 9.82 13.03 10.62
COP
Kcal/hW 2.47 3.28 2.68 2.47 3.28 2.68
Power
Factor
% — 97 — — 97 —
dB-A
44 / 37 / 34
44 / 37 / 34
Indoor Noise (H / L / QLo)
Power Level dB
60 / - / -
60 / - / -
dB-A
47 / - / -
47 / - / -
Heating
Outdoor Noise (H / L / QLo)
Power Level dB
61 / - / -
61 / - / -
Low Temp. : Capacity (kW) / I.Power (W) / COP
5.80 / 2.27k / 2.56
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
4.98 / 2.39k / 2.08
Max Current (A) / Max Input Power (W)
11.7 / 2.57k
Starting Current (A)
7.10
Type
Hermetic Motor / Rotary
Motor Type
Brushless (4 poles)
Compressor
Output Power
W
900
15
Indoor CS-HE18QKD
Model
Outdoor CU-HE18QKD
Type
Cross-Flow
Fan
Material
ASG33
Motor Type
DC / Transistor (8-poles)
Input Power
W
80.0
Output Power
W
40
Cool rpm
880
QLo
Heat rpm
860
Cool rpm
940
Lo
Heat rpm
970
Cool rpm
1030
Me
Heat rpm
1100
Cool rpm
1130
Hi
Heat rpm
1240
Cool rpm
1260
Indoor Fan
Speed
SHi
Heat rpm
1300
Type
Propeller
Fan
Material
PP
Motor Type
DC (8-poles)
Input Power
W
—
Output Power
W
40
Cool rpm
640
Outdoo
r Fa
n
Speed Hi
Heat rpm
600
Moisture Removal
L/h (Pt/h)
2.8 (5.9)
Cool m
3
/min (ft
3
/min) 14.03
(495)
QLo
Heat m
3
/min (ft
3
/min) 13.68
(483)
Cool m
3
/min (ft
3
/min) 15.08
(532)
Lo
Heat m
3
/min (ft
3
/min) 15.60
(551)
Cool m
3
/min (ft
3
/min) 16.83
(594)
Me
Heat m
3
/min (ft
3
/min) 17.53
(619)
Cool m
3
/min (ft
3
/min) 17.90
(630)
Hi
Heat m
3
/min (ft
3
/min) 19.30
(680)
Cool m
3
/min (ft
3
/min) 19.00
(671)
Indoor Airflow
SHi
Heat m
3
/min (ft
3
/min) 20.30
(717)
Cool m
3
/min (ft
3
/min) 39.2
(1385)
Outdoor
Airflow
Hi
Heat m
3
/min (ft
3
/min) 37.9
(1340)
Control Device
Expansion Valve
Refrigerant Oil
cm
3
FV50S
(450)
Refrigeration
Cycle
Refrigerant Type
g (oz)
R410A, 1.24k (43.8)
Height (I/D / O/D)
mm (inch)
295 (11-5/8) / 695 (27-3/8)
Width (I/D / O/D)
mm (inch)
1070 (42-5/32) / 875 (34-15/32)
Dimension
Depth (I/D / O/D)
mm (inch)
255 (10-1/16) / 320 (12-5/8)
Weight
Net (I/D / O/D)
kg (lb)
13 (29) / 46 (101)
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 12.70 (1/2)
Standard length
m (ft)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 20 (65.6)
I/D & O/D Height different
m (ft)
15.0 (49.2)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Piping
Length for Additional Gas
m (ft)
7.5 (24.6)
16
Indoor CS-HE18QKD
Model
Outdoor CU-HE18QKD
Inner Diameter
mm
16.7
Drain Hose
Length mm
650
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row × Stage × FPI
2 × 17 × 17
Indoor Heat
Exchanger
Size (W × H × L)
mm
836.5 × 357 × 25.4
Fin Material
Aluminium (Blue Coated)
Fin Type
Corrugated Fin
Row × Stage × FPI
2 × 31 × 19
Outdoor Heat
Exchanger
Size (W × H × L)
mm
36.4 × 651 × 854.5:824.5
Material
Polypropelene
Air Filter
Type
One-touch
Power Supply
Indoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Maximum °C
32
23
Cooling
Minimum °C
16
11
Maximum °C
30
—
Indoor
Operation
Range
Heating
Minimum °C
16
—
Maximum °C
43
26
Cooling
Minimum °C
-10
—
Maximum °C
24
18
Outdoor
Operation
Range
Heating
Minimum °C
-15
-16
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for further improvement.
Click on the first or last page to see other CS-HE7QKD / CS-HE9QKD / CS-HE12QKD / CS-HE18QKD / CU-HE7QKD / CU-HE9QKD / CU-HE12QKD / CU-HE18QKD service manuals if exist.