93
16.1.3 Detaching the Fan
1 First detach the Upper and Inner Casing
(16.1.1)
2 Disengage the 4 catches (2 each on the left
and right) on the Air Guide.
3 Use a 2.5 mm hexagonal wrench to loosen
the 2 bolts connecting the Fan Motor and Fan,
detach the shaft connecting the Fan Motor
and Fan, loosen the screw holding the Fan
and detach the Fan.
detach the shaft connecting the Fan Motor
and Fan, loosen the screw holding the Fan
and detach the Fan.
16.1.4 Detaching the Fan Motor and Drain Motor
Fan Motor
1 First detach the Upper and Inner Casing
(16.1.1) and the Fan (16.1.3).
2 Unscrew the 4 screws holding the Fan Motor
and detach it.
Drain Motor
1 First detach the Upper and Inner Casing
(16.1.1) and the Fan (16.1.3).
2 From the Fan Motor side, undo the 2 hexagon
bolts and detach the Drain Motor.
94
16.1.5 Outdoor
Electronic
Controller Removal Procedure
16.1.5.1 CU-E9PD3EA
Caution! When handling electronic controller, be careful of electrostatic discharge.
1 Remove the 5 screws of the Top Panel.
Fig. 1
2 Remove the 8 screws of the Front Panel.
Fig. 2
3 Remove the screw of the Terminal Board
Cover.
4 Remove the Top Cover of the Control Board
by 4 hooks.
Fig. 3
5 Remove the Control Board as follows:
Fig. 4
Fig. 5
Fig. 6
95
16.1.5.2 CU-E12PD3EA
1 Remove the top panel and front panel
Fig. 7
Be save to return the wiring to its original position
There are many high voltage components within the heat
sink cover so never touch the interior during operation.
Wait at least two minutes after power has been turned off.
sink cover so never touch the interior during operation.
Wait at least two minutes after power has been turned off.
2
Remove the Outdoor Electronic Controller
Fig. 8
Fig. 9
Caution! When handling electronic controller,
be careful of electrostatic discharge.
96
17. Technical
Data
Technical data provided are based on the air conditioner running under free frequency.
17.1 Cool Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C
Voltage: 220V/230V
Voltage: 220V/230V
17.1.1 CS-E9PD3EA CU-E9PD3EA
Indoor (°C)
Outdoor DB (°C)
DB WB
-10 -7 0 5
TC SHC IP TC SHC IP TC SHC IP TC
SHC
IP
27
19.0 2349 2112 511 2655 2185 527 2930 2315 507 3024
2331 448
22.0 2576 1893 520 2954 1698 433 3066 1640 492 3177
1700 451
23
15.7 2541 2165 523 2561 2180 524 2591 2267 531 2488
2177 228
18.4 2756 1711 526 2629 1709 529 2813 1744 509 2869
1787 209
20
13.3 2021 1392 294 2075 1976 369 2053 2033 324 2303
2117 482
15.8 2491 2222 557 2351 1655 565 2586 1735 521 2568
1715 531
Indoor (°C)
Outdoor DB (°C)
DB WB
16 25 35
TC SHC IP TC SHC IP TC SHC IP
27
19.0 3131 2220 343 2525 1975 524 2500 1955 581
22.0 3434 1875 322 2900 1595 581 2876 1582 580
22.0 3434 1875 322 2900 1595 581 2876 1582 580
23
15.7 2696 2194 322 2168 1849 571 2262 1930 583
18.4 3126 1813 340 2708 1633 570 2493 1503 583
18.4 3126 1813 340 2708 1633 570 2493 1503 583
20
13.3 1223 1198 114 1639 1493 226 2052 1869 585
15.8 1970 1416 179 2099 1354 347 2313 1492 586
15.8 1970 1416 179 2099 1354 347 2313 1492 586
(Dry bulb value based on 46% humidity)
17.1.2 CS-E12PD3EA CU-E12PD3EA
Indoor (°C)
Outdoor DB (°C)
DB WB
-10 -7 0 5
TC SHC IP TC SHC IP TC SHC IP TC
SHC
IP
27
19.0 3399 2408 776 3487 2460 735 3695 2526 645 3605
2505 700
22.0 4068 2053 655 3932 2014 720 4046 2042 674 3940
2019 737
23
15.7 3182 2392 705 2901 2262 825 3139 2386 720 3202
2414 718
18.4 3400 1931 748 3462 1974 725 3398 1946 769 3489
1987 743
20
13.3 2245 1969 221 2166 1939 266 2175 1941 572 2447
2061 560
15.8 2816 1763 469 2885 1769 809 3149 1916 740 3023
1854 807
Indoor (°C)
Outdoor DB (°C)
DB WB
16 25 35
TC SHC IP TC SHC IP TC SHC IP
27
19.0 3439 2418 476 3425 2438 791 3400 2420 897
22.0 4224 2110 593 3713 1930 762 3680 1913 901
22.0 4224 2110 593 3713 1930 762 3680 1913 901
23
15.7 3048 2338 419 3004 2362 843 2853 2243 888
18.4 3972 2187 587 3423 1982 758 3231 1871 894
18.4 3972 2187 587 3423 1982 758 3231 1871 894
20
13.3 2204 1951 291 2243 1975 580 2267 1996 712
15.8 2773 1740 346 2802 1800 528 2941 1814 891
15.8 2773 1740 346 2802 1800 528 2941 1814 891
(Dry bulb value based on 46% humidity)
Click on the first or last page to see other CS-E9PD3EA / CS-E12PD3EA / CU-E9PD3EA / CU-E12PD3EA service manuals if exist.