Panasonic CS-E7PKDW / CS-E9PKDW / CS-E12PKDW / CS-E15PKDW / CS-E18PKDW / CS-E24PKDW / CU-E7PKD / CU-E9PKD / CU-E12PKD / CU-E15PKD / CU-E18PKD / CU-E24PKD Service Manual ▷ View online
13
Drain Hose
Inner Diameter
mm
16.7
16.7
Length mm
650
650
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 15 x 17
2 x 15 x 21
Size (W x H x L)
mm
810 x 315 x 25.4
810 x 315 x 25.4
Outdoor
Heat
Exchanger
Fin Material
Aluminium (Blue Coat)
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Corrugated Fin
Row x Stage x FPI
2 x 31 x 19
2 x 30 x 19
Size (W x H x L)
mm
36.4 x 651 x 854.5:824.5
38.1 x 762 x 895:865
Air Filter
Material
Polypropelene
Polypropelene
Type
One-touch
One-touch
Power Supply
Outdoor Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Nil
Thermostat
Electronic Contol
Electronic Contol
Protection Device
Electronic Contol
Electronic Contol
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
Indoor
Operation
Range
Cooling
Maximum
°C
32 23 32 23
Minimum
°C
16 11 16 11
Heating
Maximum
°C
30 - 30 -
Minimum
°C
16 - 16 -
Outdoor
Operation
Range
Cooling
Maximum
°C
43 26 43 26
Minimum
°C
16 11 16 11
Heating
Maximum
°C
24 18 24 18
Minimum
°C
-5 -6 -5 -6
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5.
Specifications are subjected to change without prior notice for further improvement.
14
Multi Split Combination Possibility:
o
A single outdoor unit enables air conditioning of up to two separate rooms for CU-2E15PBD, CU-2E18PBD.
o
A single outdoor unit enables air conditioning of up to three separate rooms for CU-3E18JBE.
o
A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E23JBE, CU-4E27PBD.
o
A single outdoor unit enables air conditioning of up to five separate rooms for CU-5E34PBD.
CONNECTABLE
INDOOR UNIT
OUTDOOR UNIT
CU-2E15PBD CU-2E18PBD CU-3E18JBE
CU-4E23JBE
CU-4E27PBD
CU-5E34PBD
ROOM
A B A B A B C A B C D A B C D A B C D E
TYPE
Wall
2.2kW CS-E7PKDW
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
2.8kW CS-E9PKDW
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
3.2kW CS-E12PKDW
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
4.0kW
CS-E15PKDW
– – – – ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
5.0kW
CS-E18PKDW
– – – – ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
6.0kW
CS-E21PKDW
– – – – –
–
–
●
●
●
●
●
●
●
●
●
●
●
●
●
7.0kW
CS-E24PKDW – – – – – – – – – – – ●
●
●
●
●
●
●
●
●
Capacity range of
connectable indoor units
From 4.4kW
to 5.6kW
From 4.4kW
to 6.4kW
From 4.5kW
to 9.0kW
From 4.5kW
to 11.0 kW
From 4.5kW
to 13.6 kW
From 4.5kW
to 17.5 kW
Pipe length
1 room maximum
pipe length (m)
20 20 25
25
25
25
Allowable elevation
(m)
10 10 10
15
15
15
Total allowable
pipe length (m)
pipe length (m)
30 30 50
60
70
80
Total pipe length
for maximum
chargeless length (m)
20 20 30
30
45
45
Additional gas
amount over
chargeless length
(g/m)
20 20 20
20
20
20
Note: “●” : Available
Remarks for CU-2E15PBD / CU-2E18PBD
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-2E15PBD. (Total nominal capacity of indoor units is between
4.4kW to 5.6kW)
1) Two CS-E7PKDW only. (Total nominal cooling capacity is 4.4kW)
2) One CS-E7PKDW and one CS-E9PKEW. (Total nominal cooling capacity is 5.0kW)
Example: The indoor units’ combination below is possible to connect to CU-2E15PBD. (Total nominal capacity of indoor units is between
4.4kW to 5.6kW)
1) Two CS-E7PKDW only. (Total nominal cooling capacity is 4.4kW)
2) One CS-E7PKDW and one CS-E9PKEW. (Total nominal cooling capacity is 5.0kW)
Remarks for CU-3E18JBE / CU-4E23JBE
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-3E18JBE. (Total nominal capacity of indoor units is between
5.0kW to 9.0kW)
1) Two CS-E9PKDW only. (Total nominal cooling capacity is 5.0kW)
2) Three CS-E12PKDW. (Total nominal cooling capacity is 9.6kW)
Example: The indoor units’ combination below is possible to connect to CU-3E18JBE. (Total nominal capacity of indoor units is between
5.0kW to 9.0kW)
1) Two CS-E9PKDW only. (Total nominal cooling capacity is 5.0kW)
2) Three CS-E12PKDW. (Total nominal cooling capacity is 9.6kW)
Remarks for CU-4E27PBD / CU-5E34PBD
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable capacity range of indoor
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above)
Example: The indoor units’ combination below is possible to connect to CU-4E27PBD. (Total nominal capacity of indoor units is between
4.5kW to 13.6kW)
1) Two CS-E9PKDW only. (Total nominal cooling capacity is 5.0kW)
2) Three CS-E12PKDW. (Total nominal cooling capacity is 9.6kW)
Example: The indoor units’ combination below is possible to connect to CU-4E27PBD. (Total nominal capacity of indoor units is between
4.5kW to 13.6kW)
1) Two CS-E9PKDW only. (Total nominal cooling capacity is 5.0kW)
2) Three CS-E12PKDW. (Total nominal cooling capacity is 9.6kW)
15
Indoor Unit : CS-E7/9/12PKDW
Outdoor Unit : CU-2E15PBD
2Room 1Room
Indoor Unit Capacity (kW)
Total Indoor Capacity (kW)
Indoor Unit Capacity (kW)
Total Indoor Capacity (kW)
22+22 44 22 22
22+28 50 28 28
22+32 54 32 32
28+28 56
22+28 50 28 28
22+32 54 32 32
28+28 56
Indoor Unit : CS-E7/9/12PKDW
Outdoor Unit : CU-2E18PBD
2Room 1Room
Indoor Unit Capacity (kW)
Total Indoor Capacity (kW)
Indoor Unit Capacity (kW)
Total Indoor Capacity (kW)
22+22 44 22 22
22+28 50 28 28
22+32 54 32 32
28+28 56
22+28 50 28 28
22+32 54 32 32
28+28 56
28+32 60
32+32 64
Indoor Unit : CS-E7/9/12/15/18PKDW
Outdoor Unit : CU-3E18JBE
3Room 2Room 1Room
Indoor Unit Capacity
(kW)
Total Indoor Capacity
(kW)
Indoor Unit Capacity
(kW)
Total Indoor Capacity
(kW)
Indoor Unit Capacity
(kW)
Total Indoor Capacity
(kW)
22+22+22
66
22+28
50 22 22
22+22+28
72
22+32
54 28 28
22+22+32
76
22+40
62 32 32
22+22+40
84
22+50
72 40 40
22+28+28
78
28+28
56 50 50
22+28+32 82 28+32 60
22+28+40 90 28+40 68
22+32+32 86 28+50 78
28+28+28 84 32+32 64
28+28+32 88 32+40 72
32+50
82
40+40
80
40+50
90
16
Indoor Unit : CS-E7/9/12/15/18PKDW
Outdoor Unit : CU-4E23JBE
4Room 3Room 2Room 1Room
Indoor Unit
Capacity (kW)
Total Indoor
Capacity (kW)
Indoor Unit
Capacity (kW)
Total Indoor
Capacity (kW)
Indoor Unit
Capacity (kW)
Total Indoor
Capacity (kW)
Indoor Unit
Capacity (kW)
Total Indoor
Capacity (kW)
22+22+22+22
88 22+22+22 66 22+28 50
22
22
22+22+22+28
94 22+22+28 72 22+32 54
28
28
22+22+22+32
98 22+22+32 76 22+40 62
32
32
22+22+22+40
106
22+22+40
84 22+50 72 40 40
22+22+28+28
100
22+22+50
94 22+60 82 50 50
22+22+28+32
104 22+22+60 104 28+28
56
60
60
22+22+32+32
108
22+28+28
78 28+32 60
22+28+28+28
106
22+28+32
82 28+40 68
22+28+28+32
110
22+28+40
90 28+50 78
22+28+50
100
28+60
88
22+28+60
110
32+32
64
22+32+32
86 32+40 72
22+32+40
94 32+50 82
22+32+50
104
32+60
92
22+40+40
102
40+40
80
28+28+28
84 40+50 90
28+28+32
88
40+60
100
28+28+40
96
50+50
100
28+28+50
106 50+60 110
28+32+32
92
28+32+40
100
28+32+50
110
28+40+40
108
32+32+32
96
32+32+40
104
Click on the first or last page to see other CS-E7PKDW / CS-E9PKDW / CS-E12PKDW / CS-E15PKDW / CS-E18PKDW / CS-E24PKDW / CU-E7PKD / CU-E9PKD / CU-E12PKD / CU-E15PKD / CU-E18PKD / CU-E24PKD service manuals if exist.